Dell PowerVault 220S (SCSI) ユーザーガイド

タイプ
ユーザーガイド

このマニュアルも適しています

www.dell.com | support.dell.com
Dell™ Systems
Rack-to-Tower Conversion
Guide
2H982bk1.book Page 3 Monday, November 5, 2001 10:12 AM
Notes, Notices, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
CAUTION: A CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
WARNING: A WARNING indicates a potentially hazardous situation which, if not
avoided, may result in severe injury.
Information in this document is subject to change without notice.
© 2001 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly
forbidden.
Trademarks used in this text:
Dell
, the
DELL
logo,
RapidRails
, and
VersaRails
are trademarks of Dell Computer
Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and
names or their products. Dell Computer Corporation disclaims any proprietary interest in trademarks and trade names
other than its own.
September 2001 P/N 2H982 Rev. A01
2H982bk1.book Page 4 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-1
This conversion guide provides instructions for trained service technicians in removing
one or more Dell
systems from a rack cabinet and converting the system to a tower (or
deskside) version. One rack-to-tower conversion kit is required for each system to be
converted from a rack version system to a tower version system.
CAUTION: The system may be very heavy when fully loaded. To prevent personal
injury, do not attempt to move the system by yourself.
Safety Instructions
Use the following safety guidelines to ensure your own personal safety and to help protect
your server, storage system, or appliance from potential damage. For complete safety,
regulatory, and warranty information, refer to your System Information document.
Precautions for Rack-Mountable Products
Observe the following precautions for rack stability and safety. Also refer to the rack
installation documentation accompanying the system and the rack for specific warning
and/or caution statements and procedures.
Servers, storage systems, and appliances are considered to be components in a rack. Thus,
“component” refers to any server, storage system, or appliance, as well as to various
peripherals or supporting hardware.
WARNING: Installing Dell system components in a Dell rack without the front
and side stabilizers installed could cause the rack to tip over, potentially
resulting in bodily injury under certain circumstances. Therefore, always install
the stabilizers before installing components in the rack.
WARNING: After installing system/components in a rack, never pull more than
one component out of the rack on its slide assemblies at one time. The weight of
more than one extended component could cause the rack to tip over and injure
someone.
NOTE: Your Dell system is safety-certified as a free-standing unit and as a component for use in
a Dell rack cabinet using the Dell customer rack kit. The installation of your system and rack kit
in any non-Dell rack cabinet has not been approved by any safety agencies. It is your
responsibility to have the final combination of system and rack kit in a non-Dell rack cabinet
evaluated for suitability by a certified safety agency. Dell disclaims all liability and warranties in
connection with such combinations.
Do not move large racks by yourself. Due to the height and weight of the rack, Dell
recommends a minimum of two people to accomplish this task.
2H982bk1.book Page 1 Monday, November 5, 2001 10:12 AM
1-2 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
Before working on the rack, make sure that the stabilizers are secured to the rack,
extend to the floor, and that the full weight of the rack rests on the floor. Install front
and side stabilizers on a single rack or front stabilizers for joined multiple racks before
working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the rack first.
Make sure that the rack is level and stable before extending a component from the
rack.
Use caution when pressing the component rail release latches and sliding a component
into or out of a rack; the slide rails can pinch your fingers.
After a component is inserted into the rack, carefully extend the rail into a locking
position, and then slide the component into the rack.
Do not overload the AC supply branch circuit that provides power to the rack.
The total rack load should not exceed 80 percent of the branch circuit rating.
Ensure that proper airflow is provided to components in the rack.
Do not step on or stand on any system/component when servicing other
systems/components in a rack.
Rack-to-Tower Kit Contents
The rack-to-tower kit includes the following items (see Figure 1-1):
One tower bezel, including keylock and keys
One tower front panel
One tower left-side cover
One tower right-side cover
One tower base assembly
Four ¼-20 x 0.5-inch hex socket-head screws
Four ¼ x 1 x 0.08-inch flat washers
Two round covers
2H982bk1.book Page 2 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-3
Figure 1-1. Rack-to-Tower Kit Contents
tower bezel, system badge
assembly, and keylock
¼-20 x 0.5-inch hex
socket-head screws (4)
tower front panel
round covers (2)
tower left and
right covers
¼ x 1 x 0.08-inch
washers (4)
base assembly
2H982bk1.book Page 3 Monday, November 5, 2001 10:12 AM
1-4 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
Before You Begin
Before you begin removing your system from the rack and converting it to a tower system,
carefully read “Safety Instructions.”
Removing the Rack Doors
See the procedures for removing doors in the documentation provided with your rack
cabinet.
Recommended Tools and Supplies
The following tools are required to perform the conversion:
A #2 Phillips screwdriver
A 3/16-inch hex-head (Allen) wrench
A Torx T-10 driver (for removing and installing the front panels)
Conversion Tasks
Removing a system from the rack and removing the RapidRails™ or VersaRails™ rack
mounting hardware from the rack cabinet includes the following tasks:
Removing the rack doors
Removing the system from the rack
Removing the front panel
Installing the tower front panel
Installing the base, covers, and bezel
Removing the RapidRails or VersaRails mounting rail assemblies
Replacing the rack doors
2H982bk1.book Page 4 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-5
Removing the Rack Doors
You must remove the doors from the rack cabinet to provide access to the interior of the
rack and to prevent damage to the doors.
For Dell rack cabinets, see the documentation provided with the rack for instructions on
removing rack doors.
Removing the System From the Rack
CAUTION: If you are removing more than one system from the rack cabinet,
remove the highest of the systems first. Complete the removal of the first
system from the rack before starting the second. Never extend more than one
system from the rack at a time.
WARNING: Removing a system from a position high up in the rack cabinet
requires up to four people and might require a sturdy, elevated platform on
which to stand. A mechanical lifting platform or similar equipment of the proper
capacity might also be useful. If you attempt to remove and lower the system
without enough people to safely perform the task, you risk personal injury to
yourself and others and damage to the system.
1 Shut down and turn off the system.
See the Installation and Troubleshooting Guide for instructions.
2 Disconnect the cables and power cord from the back of the system.
3 Loosen the thumbscrews that secure the front panel to the front vertical rails (at the
front of the rack cabinet).
4 Using two or more persons, grasp the system at each front handle and slide the system
out of the rack mounting rails (see Figure 1-2).
5 Place the system on a smooth work surface.
Position the system so that the front panel extends 2.54 centimeters (1 inch) beyond
the edge of the table or work surface.
2H982bk1.book Page 5 Monday, November 5, 2001 10:12 AM
1-6 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
Figure 1-2. Removing the System From the Mounting Rail Assemblies
Removing the Front Panel
This procedure is best performed with the front of the system extending 2.54 centimeters
(1 inch) beyond the edge of the work surface or table.
1 Label and remove the hard drives from the system.
NOTE: Although not necessary for the conversion, you might want to remove the two
power supply and cooling modules at the back of the system chassis to reduce the weight of
the chassis while you are performing this and the following procedures. See the
Installation
and Troubleshooting Guide
for instructions on removing and replacing the modules.
2 Remove the 14 T-10 Torx screws that secure the front panel to the chassis.
3 Pull the front panel away from the system chassis, using care to avoid damaging the
five plastic light pipes that extend through the front panel (see Figure 1-3).
thumbscrew
2H982bk1.book Page 6 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-7
Installing the Tower Front Panel
1 Position the tower front panel in place on the system chassis, using care to install the
five light pipes in their holes in the front panel.
NOTE: In the next step, start all 14 T-10 Torx screws in their holes before tightening any of the
screws to ensure proper alignment.
2
Install the tower front panel on the chassis, securing it with the 14 T-10 Torx screws
that you removed in step 2 of the last procedure, “Removing the Front Panel.”
Figure 1-3. Installing the Tower Front Panel
screws (14)
light pipes (5)
2H982bk1.book Page 7 Monday, November 5, 2001 10:12 AM
1-8 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
Installing the Base, Covers, and Bezel
1 To install the base:
a Position the base assembly and align the two holes on its underside with the two
threaded holes on the right side (the base) of the chassis (see Figure 1-4).
b Secure the two hex-socket-head screws and flat washers to the base using a
3/16-inch hex (Allen) wrench.
2 To replace the system right and left covers:
a Raise the system into the tower position, resting on its base.
b Position the covers on their respective sides of the chassis 12.7 millimeters
(0.5 inch) behind the front panel.
Tabs on the bottom of each cover should drop into slots in the base assembly.
c Slide the covers toward the front panel until two holes on the top of the cover
align with two threaded holes in the system chassis.
d Use a 3/16-inch hex (Allen) wrench to secure the two hex-socket-head screws and
flat washers into the two holes at the top of the system.
e Install round covers over the screws you just installed (see Figure 1-4).
2H982bk1.book Page 8 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-9
Figure 1-4. Installing the Tower System Cover
¼ x 1 x 0.08-inch flat
washers (4)
¼-20 x 0.5-inch hex-
socket-head screws (4)
round covers (2)
2H982bk1.book Page 9 Monday, November 5, 2001 10:12 AM
1-10 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
3 To install the bezel:
a Position the bezel so it is perpendicular to the system.
b Install the two captive thumbscrews in their holes at the bottom of the front
panel.
c Reinstall the hard drives and power and cooling modules, if they were removed
(see the Installation and Troubleshooting Guide for instructions).
d Close the bezel.
See the Installation and Troubleshooting Guide for information about installing and
configuring your system.
Figure 1-5. Installing the Tower Front Bezel
thumbscrew
bezel
2H982bk1.book Page 10 Monday, November 5, 2001 10:12 AM
Rack-to-Tower Conversion Guide 1-11
Removing the RapidRails Mounting Rails
NOTE: If you have VersaRails mounting rails in your rack cabinet, skip to the procedure,
“Removing the VersaRails Mounting Rails.”
1
At the front of the rack cabinet, locate the blue release push button on one of the
RapidRails mounting rail’s mounting-bracket flanges (see Figure 1-6).
Figure 1-6. Removing the Mounting Rails
rail mounting-bracket flange
blue release push button
front of rack
mounting rails (2)
mounting hooks
VersaRails
RapidRails
2H982bk1.book Page 11 Monday, November 5, 2001 10:12 AM
1-12 Rack-to-Tower Conversion Guide
www.dell.com | support.dell.com
2 From the front of the rack cabinet, press in on the blue release push button, grasp the
rail and lift up, and push the slide assembly back 2.54 centimeters (1 inch) away from
the front vertical rail until the mounting-bracket flange and its mounting hooks
disengage from the square holes in the front vertical rail (see Figure 1-6).
3 Repeat step 2 at the back of the cabinet for this mounting rail.
4 Repeat steps 1 through 3 for the remaining mounting rail on the other side of the rack.
5 Place the mounting rails and all fastener hardware in a box. Label the box as a rack
installation kit for the system model you removed from the rack.
This completes the procedure for removing the RapidRails mounting rails from a rack.
Removing the VersaRails Mounting Rails
1 At the front of the rack cabinet, remove the two 10-32 x 0.5-inch Phillips screws on
one of the VersaRails mounting-bracket flanges (see Figure 1-6).
2 Push back on the front mounting-flange bracket 2.54 centimeters (1 inch).
3 At the back of the rack cabinet, remove the two 10-32 x 0.5-inch Phillips screws that
secure the rear mounting-bracket flange to the rack’s vertical rail.
4 Repeat steps 1 through 3 for the remaining mounting rail on the other side of the rack.
5 Place the mounting rails and all fastener hardware in a box. Label the box as a rack
installation kit for the system model you removed from the rack.
This completes the procedure for removing the VersaRails mounting rails from a rack.
Replacing the Rack Doors
See the procedures for replacing doors in the documentation provided with your Dell rack
cabinets.
This completes the tower conversion of your system.
2H982bk1.book Page 12 Monday, November 5, 2001 10:12 AM
www.dell.com | support.dell.com
Systèmes Dell™
Guide de conversion de rack
en tour
2H982bk1.book Page 1 Monday, November 5, 2001 10:12 AM
Remarques, mises en gardes et avertissements
REMARQUE : UNE REMARQUE indique une information importante destinée à vous aider à
mieux utiliser votre ordinateur.
MISE EN GARDE : UNE MISE EN GARDE indique un dommage potentiel pouvant survenir
(ou une perte de données) et vous dit comment éviter le problème.
ATTENTION : Le message ATTENTION indique une situation potentiellement
dangereuse qui, si elle n'est pas évitée, peut provoquer une blessure mineure ou
modérée.
AVERTISSEMENT : Le message AVERTISSEMENT indique une situation
potentiellement dangereuse qui, si elle n'est pas évitée, peut provoquer une
blessure mineure ou modérée.
Les informations fournies dans ce guide sont susceptibles d'être modifiées sans préavis.
© 2001 Dell Computer Corporation. Tous droits résers.
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Computer Corporation
est strictement interdite.
Marques déposées utilisées dans ce guide :
Dell
, le logo
DELL RapidRails
et
VersaRails
sont des marques commerciales
de Dell Computer Corporation.
Toutes les autres marques déposées et noms de marques utilisés dans ce document se rapportent aux sociétés
propriétaires des marques et des noms de ces produits. Dell Computer Corporation décline tout intérêt dans l'utilisation
des marques déposées et des noms de marques ne lui appartenant pas.
Septembre 2001 Réf. 2H982 Rév. A01
2H982bk1.book Page 2 Monday, November 5, 2001 10:12 AM
Guide de conversion de rack en tour 2-1
Ce guide de conversion contient des instructions destinées aux techniciens de maintenance
qualifiés et explique comment retirer un ou plusieurs systèmes Dell™
d’une armoire rack
pour les convertir en version tour ou de bureau. Un kit de conversion de rack en tour est
nécessaire pour chacun des systèmes à convertir.
ATTENTION : Votre système peut être extrêmement lourd lorsqu'il est
entièrement chargé. Pour éviter toute blessure, ne tentez pas de le déplacer
seul.
Instructions de sécurité
Respectez les consignes de sécurité de ce guide pour assurer votre sécurité personnelle et
pour contribuer à protéger votre serveur, votre système de stockage ou appareil, des
dommages potentiels. Pour obtenir toutes les informations de sécurité, réglementaires et les
garanties, reportez-vous au document intitulé Informations système.
Précautions à suivre concernant les produits destinés à être montés dans des
racks
Pour la stabilité du rack et pour votre sécurité, veuillez respecter les précautions suivantes.
Reportez-vous également à la documentation accompagnant le système et le rack pour
connaître les avertissements et/ou les mises en garde et les procédures spécifiques.
Les serveurs, les systèmes de stockage et les appareils sont considérés comme les
composants d'un rack. Ainsi, le terme "composant" fait référence à tout serveur, tout
système de stockage ou appareil, aussi bien qu'aux différents périphériques ou matériels.
AVERTISSEMENT : L'installation de composants d'un système Dell dans un rack
sans placer de stabilisateurs avant et latéraux peut provoquer le basculement du
rack, et générer des blessures potentielles dans certaines situations. C'est
pourquoi il faut toujours installer les stabilisateurs avant d'installer les
composants du rack.
AVERTISSEMENT : Après avoir installé le système/les composants dans un rack,
ne tirez jamais plus d'un composant du rack sur les supports coulissants. Le
poids représenté par plus d'un composant étendu pourrait en effet provoquer le
basculement du rack et blesser l'utilisateur.
REMARQUE : Votre système Dell est certifié sur le plan de la sécurité en tant qu'unité
autonome et en tant que composant destiné à être utilisé dans une armoire rack Dell, à l'aide du
kit de rack client de Dell. L'installation du système et du kit de rack Dell dans un rack d'une
autre marque n'a reçu aucune homologation des organismes de certification de la sécurité. Il est
de votre entière responsabilité de faire évaluer par un organisme de sécurité agréé la
combinaison finale du système et du kit de rack Dell dans un rack d'une autre marque. Dell
décline toute responsabilité et toutes garanties liées à ce type de combinaisons.
2H982bk1.book Page 1 Monday, November 5, 2001 10:12 AM
2-2 Guide de conversion de rack en tour
www.dell.com | support.dell.com
Ne déplacez pas seul les racks volumineux. En raison de la hauteur et du poids du rack,
Dell recommande que cette tâche soit réalisée par deux personnes au minimum.
Avant de travailler sur le rack, assurez-vous que les stabilisateurs sont bien en place sur
le rack et au sol, et que tout le poids du rack repose sur le sol. Installez les
stabilisateurs avant et latéraux (pour un rack simple) ou les stabilisateurs avant (pour
les racks multiples) avant de travailler sur le rack.
Chargez toujours le rack du bas vers le haut, en plaçant toujours la plus forte charge en
premier.
Assurez-vous que le rack est bien de niveau avant de sortir l'un des composants à l'aide
des supports coulissants.
Agissez avec précaution lorsque vous appuyez sur les verrous des rails pour les libérer
et faire glisser un composant hors ou dans le rack. Les rails coulissants pourraient en
effet vous coincer les doigts.
Après avoir inséré un composant dans le rack, étendez le rail en position maximum
jusqu'à son verrouillage puis faites glisser le composant dans le rack.
Ne surchargez pas le circuit d'alimentation c.a. dérivé alimentant le rack en électricité.
La charge totale du rack ne doit pas excéder 80 % de la puissance du circuit dérivé.
Assurez-vous que l'air circule suffisamment entre les composants du rack.
Ne montez jamais sur l'un des composants du système lors de l'entretien.
Contenu du kit de conversion de rack en tour
Le kit de conversion de rack en tour comprend les éléments suivants (voir la figure 2-1) :
Un cache de tour, avec verrou et clés
Un panneau frontal de tour
Un capot latéral gauche
Un capot latéral droit
La base de la tour
Quatre vis à tête cylindrique à 6 pans ¼-20 x 0,5 pouces
Quatre rondelles plates ¼ x 1 x 0,08 pouces
Deux capuchons ronds
2H982bk1.book Page 2 Monday, November 5, 2001 10:12 AM
Guide de conversion de rack en tour 2-3
Figure 2-1. Contenu du kit de conversion de rack en tour
cache de la tour, base du
système et verrou
vis à tête cylindrique à 6
pans ¼-20 x 0,5 pouces (4)
panneau frontal de tour
capuchons ronds (2)
capots gauche et
droit
rondelles ¼ x 1 x
0,08 pouces
(4)
base
2H982bk1.book Page 3 Monday, November 5, 2001 10:12 AM
2-4 Guide de conversion de rack en tour
www.dell.com | support.dell.com
Avant de commencer
Avant de retirer le système du rack pour le convertir en tour, lisez attentivement les
“Instructions de sécurité”.
Retrait des portes du rack
Reportez-vous aux procédures de retrait des portes dans la documentation fournie avec le
rack.
Outils et fournitures recommandés
Vous devez utiliser les outils suivants pour effectuer la conversion :
Un tournevis Phillips n°2
Une clé mâle (Allen) 3/16 pouces
Un tournevis Torx T-10 (pour le retrait et l’installation des panneaux avant)
Opérations de conversion
Pour retirer un système de son rack ainsi que le support de montage en rack des rails
RapidRails™ ou VersaRails™, procédez comme suit :
Retrait des portes du rack
Retrait du système du rack
Retrait du panneau frontal
Installation du panneau frontal de la tour
Installation de la base, des capots et du cache
Retrait des rails de montage RapidRails ou VersaRails
Remise en place des portes du rack
2H982bk1.book Page 4 Monday, November 5, 2001 10:12 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Dell PowerVault 220S (SCSI) ユーザーガイド

タイプ
ユーザーガイド
このマニュアルも適しています