Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury,
or death.
____________________
Information in this document is subject to change without notice.
© 2003 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, and Dell OpenManage are trademarks of Dell Computer Corporation;
Novell and NetWare are registered trademarks of Novell, Inc.; Intel is a registered trademark and Xeon is a trademark of
Intel Corporation; Red Hat is a registered trademark of Red Hat, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and
names or their products. Dell Computer Corporation disclaims any proprietary interest in trademarks and trade names
other than its own.
July 2003 P/N H0544 Rev. A05
H0544ebk5.book Page 2 Tuesday, July 8, 2003 9:14 AM
Information Update 1-1
This document provides updated information for your system on the following topics:
Processor
Flashing the system BIOS
Installing the Red Hat
®
Linux Advanced Server 2.1 operating system
COM2 availability
Teamed NIC addresses with the Novell
®
NetWare
®
6.0 operating system
Installing a processor
Installing or removing a ROMB backup battery
Connecting external SCSI devices
System message update
Processor
Your system contains up to two Intel
®
Xeon™ processors with a front-side bus speed of
either 400 or 533 MHz, and a minimum internal operating frequency of 2.4 GHz.
In systems with a 400-MHz front-side bus, the 266-MHz DDR SDRAM memory modules
run at 200 MHz.
Flashing the System BIOS
If you need to flash the system’s BIOS, go to the Dell Support website at support.dell.com
and download the most current BIOS available for your system. Do not use the system
BIOS that was provided on your Dell OpenManage Server Assistant CD.
Installing Red Hat Linux Advanced Server 2.1
Dell recommends installing Red Hat Linux Advanced Server 2.1 using the Server Assistant
CD, which ensures proper loading of all the drivers and avoids use of the driver update
diskette. If you intend to install Red Hat Linux using the driver update diskette instead of
the Server Assistant CD, ensure that you download the latest drivers for Red Hat Linux
Advanced Server 2.1 from the Dell Support website at support.dell.com.
H0544ebk5.book Page 1 Tuesday, July 8, 2003 9:14 AM
1-2 Information Update
www.dell.com | support.dell.com
The updated drivers on the Dell Support website include the latest script file, which
prevents future erroneous error messages by ensuring that the drivers for the embedded
SCSI controller are placed in the correct location.
Run the script file after installing the operating system. See the readme file included with
the updated drivers for more information about running the script file.
COM2 Availability
COM2 circuitry exists on the system board, but it is reserved for use by an optional ERA/O
controller. Although COM2 may be reported as available under certain operating systems,
COM1 is the only serial port that is available on your system.
Teamed NIC Addresses With Novell
NetWare 6.0
When two or more Gigabit Ethernet Channel or 802.3ad NICs are set up as a team when
running the Novell NetWare 6.0 operating system, the team is assigned a single media
access control (MAC) address that identifies the team to the network. The Broadcom
Advanced Server program driver that is used to form the team displays the MAC address as
FFFFFFFFFFFF rather than displaying the correct address of the team.
This issue does not affect the functionality of the team, since the team address is available
to the network.
Installing a Processor
Always use the new heat sink that ships with a processor upgrade kit. Thermal interface
grease on the underside of the heat sink is critical to maintaining optimum contact between
the heat sink and the processor. Used or older heat sinks may not have enough grease
remaining on it to ensure proper contact.
Installing or Removing a ROMB Backup
Battery
If an ERA/O controller is installed under the ROMB backup battery, remove the SCSI
backplane board before removing or installing the battery, and replace the SCSI backplane
board after removing or installing the battery.
H0544ebk5.book Page 2 Tuesday, July 8, 2003 9:14 AM
Information Update 1-3
CAUTION: Before you perform this procedure you must turn off the system and
disconnect it from its power source. See your System Information Guide for
complete information about safety precautions, working inside the computer,
and protecting against electrostatic discharge.
NOTE: The following two procedures assume that you have already removed the
system covers and performed the initial steps of "Installing a ROMB Card" or
"Removing a ROMB Card" in your Installation and Troubleshooting Guide.
Removing the SCSI Backplane Board
1 Pull each hard-drive carrier partially out of its slot, approximately 2.5 cm (1 inch).
2 Disconnect the diskette-drive interface cable from the FLOPPY connector on the
backplane board. See Figure 1-1.
3 Disconnect the CD drive interface cable from the CD_ROM connector on the
backplane board. See Figure 1-1.
4 Press the release latch in toward the backplane board and use the handle to pull the
board out of its connector and up out of the chassis. See Figure 1-1.
Installing the SCSI Backplane Board
1 Insert the SCSI backplane board into the chassis:
a Fit the metal tabs (one tab at each end of the backplane) into the slots in the
chassis wall and lower the backplane into the chassis, ensuring that the CD and
diskette drive interface cables are not caught under the backplane. See Figure 1-1.
b Press down firmly over the handle to seat the backplane in its connector.
2 Pivot the release latch out into the securing slot in the chassis.
3 Connect the CD drive interface cable to the CD_ROM connector on the backplane
board.
4 Connect the diskette-drive interface cable to the FLOPPY connector on the backplane
board.
5 Press all installed hard drives firmly back into the SCSI connectors on the backplane.
H0544ebk5.book Page 3 Tuesday, July 8, 2003 9:14 AM
1-4 Information Update
www.dell.com | support.dell.com
Figure 1-1. SCSI Backplane Board
Connecting External SCSI Devices
You can connect external SCSI devices to the external SCSI connector on the system’s back
panel or to an installed SCSI controller card.
CD drive interface
connector
diskette drive interface connector
handle
release latch
tabs (2)
H0544ebk5.book Page 4 Tuesday, July 8, 2003 9:14 AM
Information Update 1-5
System Message Update
The system messages shown in Table 1-1 have been added or updated.
Table 1-1. System Messages
Message Causes Corrective Actions
Caution! NVRAM_CLR
jumper is installed on
system board - please
run SETUP program.
NVRAM_CLR jumper is
installed.
Remove the NVRAM_CLR
jumper. See Figure A-2 in the
Installation and Troubleshooting
Guide for jumper location.
Invalid configuration
information - please
run SETUP program.
Invalid configuration settings in
the System Setup program, or
the system battery is faulty.
Check the System Setup
configuration settings. See
"Using the System Setup
Program" in your User’s Guide.
Replace the battery. See
"Replacing the System Battery"
in the Installation and
Troubleshooting Guide.
This processor system
bus speed is unknown.
System halted!
The installed processor is not
supported by the system.
Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace the installed processor(s)
with processor(s) supported by
your system. See "Processors" in
the Installation and
Troubleshooting Guide.
If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper locations.
H0544ebk5.book Page 5 Tuesday, July 8, 2003 9:14 AM
1-6 Information Update
www.dell.com | support.dell.com
Processor 1 is a
533-MHz system bus
processor.
Processor 2 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
Two 533-MHz processors are
installed. This system supports
only Intel Xeon 400-MHz front-
side-bus processors.
Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace both processors with
Intel Xeon 400-MHz front-side-
bus processors. See "Processors"
in the Installation and
Troubleshooting Guide.
If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper locations.
Processor 1 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
A 533-MHz processor is installed
in processor slot 1. This system
supports only Intel Xeon
400-MHz front-side-bus
processors.
Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace processor 1 with an Intel
Xeon 400-MHz front-side-bus
processors. See "Processors" in
the Installation and
Troubleshooting Guide.
If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper location.
Table 1-1. System Messages (continued)
Message Causes Corrective Actions
H0544ebk5.book Page 6 Tuesday, July 8, 2003 9:14 AM
www.dell.com | support.dell.com
Dell
系统
信息更新
H0544cbk5.book Page 1 Friday, July 11, 2003 12:47 PM
注意和警告
注表示可以帮助您更好地使用计算机的重要信息
注意
注意表示可能会损坏硬件或导致数据丢失 并告诉您如何避免此类问题
警告
警告
警告表示存在可能导致财产损失 人身伤害或死亡的潜在危险
____________________
本文件中的信息如有更改 恕不另行通知
© 2003 Dell Computer Corporation
版权所有 翻印必究
未经
Dell Computer Corporation
书面许可 不准以任何形式进行复制
本文件中使用的商标
Dell DELL
徽标和
Dell OpenManage
Dell Computer Corporation
的商标
Novell
NetWare
Novell, Inc.
的注册商标
Intel
Intel Corporation
的注册商标
Xeon
是其商标
Red Hat
Red Hat, Inc.
的注册商标
本文件中述及的其它商标和产品名称是指拥有相应商标和名称的公司或其制造的产品
Dell Computer
Corporation
对其它公司的商标和产品名称不拥有任何专利权
2003
7
P/N H0544 Rev. A05
H0544cbk5.book Page 2 Friday, July 11, 2003 12:47 PM
信息更新
2-1
本说明文件提供了有关系统的更新信息 涉及以下主题
处理器
刷新系统
BIOS
安装
Red Hat
®
Linux Advanced Server 2.1
操作系统
COM2
可用性
Novell
®
NetWare
®
6.0
操作系统下的组队
NIC
地址
安装处理器
安装或卸下
ROMB
备用电池
连接外部
SCSI
设备
系统信息更新
处理器
您的系统包含多达两个
Intel
®
Xeon
处理器
前侧总线速率为
400
533MHz
最低
内部操作速率为
2.4GHz
在前侧总线速率为
400MHz
的系统中
266MHz DDR SDRAM
存储器模块以
200MHz
的速率运行
刷新系统
BIOS
如果您需要刷新系统的
BIOS
请访问
Dell
支持
Web
站点
support.dell.com
然后下载
适用于您的系统的最新
BIOS
请勿使用随
Dell OpenManage Server Assistant CD
附带
的系统
BIOS
安装
Red Hat Linux Advanced Server 2.1
Dell
建议使用
Server Assistant CD
来安装
Red Hat Linux Advanced Server 2.1
这样可以
确保正确载入所有驱动程序
并且无需使用驱动程序更新软盘 如果您希望使用驱动
程序更新软盘而不是
Server Assistant CD
来安装
Red Hat Linux
请确保从
Dell
支持
Web
站点
support.dell.com
下载适用于
Red Hat Linux Advanced Server 2.1
的最新驱动
程序
H0544cbk5.book Page 1 Friday, July 11, 2003 12:47 PM
2-2
信息更新
www.dell.com | support.dell.com
Dell
支持
Web
站点上的更新驱动程序包含最新的脚本文件
可以确保将嵌入式
SCSI
控制器的驱动程序放置在正确的位置
从而避免将来出现不正确的错误信息
安装操作系统之后 请运行该脚本文件 有关运行该脚本文件的详情 请参阅更新驱
动程序中附带的自述文件
COM2
可用性
COM2
电路存在于主机板上
但是已保留为由可选
ERA/O
控制器使用 尽管
COM2
在某些操作系统中可能会被报告为可供使用
COM1
仍然是系统上唯一可供使用的
串行端口
Novell NetWare 6.0
下的组队
NIC
地址
Novell NetWare 6.0
操作系统下运行时 如果安装了两个或更多
Gigabit Ethernet
Channel
802.3ad NIC
则会为该组队分配一个在网络中对其进行识别的单个介质访
问控制
(MAC)
地址
用于形成组队的
Broadcom Advanced Server
驱动程序会将
MAC
地址显示为
FFFFFFFFFFFF
而不是显示正确的组队地址
此问题不会影响组队的功能 因为组队地址将供网络使用
安装处理器
务必使用随处理器升级套件附带的新散热器 散热器底部的散热膏对确保散热器与处
理器之间的接触良好起着至关重要的作用
已用过的或旧的散热器可能没有足够的散
热膏
无法确保正确接触
安装或卸下
ROMB
备用电池
如果
ROMB
备用电池下方安装了
ERA/O
控制器 请在拆卸或安装电池之前先卸下
SCSI
底板
然后在卸下或安装电池之后装回
SCSI
底板
警告
执行此过程之前 必须先关闭系统并断开其电源连接 有关安全预防措施 拆装计
算机内部组件以及防止静电损害的完整信息
请参阅 系统信息指南
以下两个过程假设您已卸下主机盖 并且已执行 安装与故障排除指南 中的 安装
ROMB
卸下 ROMB 所介绍的初始步骤
H0544cbk5.book Page 2 Friday, July 11, 2003 12:47 PM
信息更新
2-3
卸下
SCSI
底板
1
将每个硬盘驱动器托盘从其插槽中部分拉出 大约拉出
2.5
厘米
1
英寸
2
从底板上的
FLOPPY
连接器中断开软盘驱动器接口电缆的连接 请参阅图
2-1
3
从底板上的
CD_ROM
连接器中断开
CD
驱动器接口电缆的连接 请参阅图
2-1
4
将释放闩锁朝底板方向按下 然后使用手柄将底板从连接器中拉出并从机箱中取
请参阅图
2-1
安装
SCSI
底板
1
SCSI
底板插入机箱
a
将金属卡舌 底板每端各一个 套入机箱壁上的槽孔中 然后将底板向下放入
机箱
并确保
CD
和软盘驱动器接口电缆不会被压在底板下 请参阅图
2-1
b
稳定地向下按压手柄 使底板在其连接器中
2
将释放闩锁向外入机箱上的定槽孔中
3
CD
驱动器接口电缆连接至底板上的
CD_ROM
连接器
4
将软盘驱动器接口电缆连接至底板上的
FLOPPY
连接器
5
将所有已安装的硬盘驱动器稳定地按入底板上的
SCSI
连接器中
H0544cbk5.book Page 3 Friday, July 11, 2003 12:47 PM
2-4
信息更新
www.dell.com | support.dell.com
2-1
SCSI
底板
连接外部
SCSI
设备
您可以将外部
SCSI
设备连接至系统背面板上的外部
SCSI
连接器 连接至已安装
SCSI
控制器卡
CD 驱动器接口连接器
软盘驱动器接口连接器
手柄
释放闩锁
卡舌
2
H0544cbk5.book Page 4 Friday, July 11, 2003 12:47 PM
信息更新
2-5
系统信息更新
2-1
中所示的系统信息已添加或更新
2-1
系统信息
信息 原因 纠正措施
Caution! NVRAM_CLR
jumper is installed on
system board - please
run SETUP program.
警告
NVRAM_CLR
跳线已
安装在主机板上
-
请运行系统
设置程序
已安装
NVRAM_CLR
跳线 卸下
NVRAM_CLR
跳线 有关
跳线位置
请参阅 安装与故障
排除指南
中的图
A-2
Invalid configuration
information - please
run SETUP program.
无效的配置信息
-
请运行系
统设置程序
系统设置程序中的配置设置
无效
或者系统电池出现
故障
检查系统设置程序的配置设置
请参阅 用户指南 中的 使用
系统设置程序
更换电池
参阅
安装与故障排除指南
更换系统电池
This processor system
bus speed is unknown.
System halted!
此处理器系统总线速率未知
系统停机
系统不支持已安装的处理器 重新引导系统 如果出现哔声代
4-4-3
处理器频率不符
将已安装的处理器更换为系统支
持的处理器
请参阅 安装与故
障排除指南
中的 处理器
如果系统引导时未出现哔声代
请关闭系统并安装
NVRAM_CLR
跳线
然后重新
引导系统
有关跳线位置 请参
安装与故障排除指南
的图
5-2
H0544cbk5.book Page 5 Friday, July 11, 2003 12:47 PM
2-6
信息更新
www.dell.com | support.dell.com
Processor 1 is a
533-MHz system bus
processor.
Processor 2 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
处理器
1
533MHz
系统
总线处理器
处理器
2
533MHz
系统总线处理器
本系统仅支持
400MHz
系统
总线速率
系统停机
安装了两个
533MHz
处理器
本系统仅支持
Intel Xeon
400MHz
前侧总线处理器
重新引导系统 如果出现哔声代
4-4-3
处理器频率不符
请将两个处理器均更换为
Intel
Xeon 400MHz
前侧总线处理器
请参阅 安装与故障排除指南
中的 处理器
如果系统引导时未出现哔声代
请关闭系统并安装
NVRAM_CLR
跳线
然后重新
引导系统
有关跳线位置 请参
安装与故障排除指南
的图
5-2
Processor 1 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
处理器
1
533MHz
系统
总线处理器
本系统仅支持
400MHz
系统总线速率
系统
停机
处理器插槽
1
中安装了一个
533MHz
处理器
本系统仅支
Intel Xeon 400MHz
前侧总
线处理器
重新引导系统 如果出现哔声代
4-4-3
处理器频率不符
请将处理器
1
更换为
Intel Xeon
400MHz
前侧总线处理器
请参
安装与故障排除指南
处理器
如果系统引导时未出现哔声代
请关闭系统并安装
NVRAM_CLR
跳线
然后重新
引导系统
有关跳线位置 请参
安装与故障排除指南
的图
5-2
2-1
系统信息
信息 原因 纠正措施
H0544cbk5.book Page 6 Friday, July 11, 2003 12:47 PM
www.dell.com | support.dell.com
Systèmes Dell™
Mise à jour des
informations
H0544fbk5.book Page 1 Tuesday, July 8, 2003 9:19 AM
Remarques, mises en garde et avertissements
REMARQUE : Une REMARQUE contient des informations importantes destinées à vous aider à
mieux utiliser votre ordinateur.
MISE EN GARDE : Une MISE EN GARDE vous avertit d'un dommage ou d'une perte de
données potentiels et vous indique comment éviter ce problème.
ATTENTION : Le message ATTENTION indique une situation potentiellement
dangereuse qui, si elle n'est pas évitée, peut provoquer une détérioration du
matériel ou des blessures pouvant entraîner la mort.
____________________
Les informations fournies dans ce document sont susceptibles d'être modifiées sans préavis.
© 2003 Dell Computer Corporation. Tous droits réservés.
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Computer Corporation
est strictement interdite.
Marques commerciales utilisées dans ce document : Dell, le logo DELL et Dell OpenManage sont des marques
commerciales de Dell Computer Corporation ; Novell et NetWare sont des marques déposées de Novell, Inc. ; Intel est une
marque déposée et Xeon est une marque commerciale d'Intel Corporation ; Red Hat est une marque déposée de Red Hat, Inc.
Tous les autres noms de marques et marques commerciales utilisés dans ce document se rapportent aux sociétés propriétaires
des marques et des noms de ces produits. Dell Computer Corporation décline tout intérêt dans l'utilisation des marques
déposées et des noms de marques ne lui appartenant pas.
Juillet 2003 Réf H0544 Rév. A05
H0544fbk5.book Page 2 Tuesday, July 8, 2003 9:19 AM
/