Bitspower BPTA-WDPGR701 インストールガイド

  • Bitspower Sedna GR701水冷システムの取扱説明書について、ご質問にお答えします。この説明書には、インストール手順、メンテナンス方法、トラブルシューティングガイドなどが記載されています。ご不明な点がありましたら、お気軽にご質問ください。
  • 冷却液は何を使用すれば良いですか?
    取り付け前に確認すべきことはありますか?
    水路の空気抜きはどうすれば良いですか?
[ 1 ]
instruction manual
Digital RGB PIN on 1motherboard or 2other equipment.
motherboard DRGB Multi Function Controller
(Not included)
BPTA-DRGBMFC
12
Accessories
1M4x6 Screw 10 PCS
Bitspower Sedna GR701 for
ASUS ROG HYPERION GR701 V2
BPTA-WDPGR701
2BPTA-EFW-GS 1 PCS 3Fitting + soft tube 1 PCS
4BP-BB2WP-P02 1 PCS 5C32-WTP 1 PCS
[ 2 ]
Power Supply and Pump
SPECIFICATION
Rated voltage:12V DC
Power consumption:15W
Maximum 󼴪ow:11±15% L/min
Noise:≤ 40dBA
PWM:Yes
MTBF:15000 hours
Warranty:2 years
Dimension: 62 x 62 x 46.7mm
Maximum lift of the water pump: 5.5±0.5m
※ The position of the Hole position o󼴨set block can
be adjusted to correspond to the CPU installation
position of di󼴨erent motherboards.
If need be
O-Ring(54×50×2mm)
Water conduit modules
Hole o󼴨set block(CPU)
M4×16mm Screw
O-Ring(60×56×2mm)
※When installing the GPU, it is necessary to
remove the conduit module, and then install the
corresponding 󼴩ttings.
G1/4 Screw plug
All tube connect hole sare G 1/4 threaded holes.
Conduit
G1/4 thread plug
M4×16mm Screw When installing the radiator, it is necessary to
remove the conduit module, and then install the
corresponding 󼴩ttings.
[ 3 ]
Water
Choose your desired dye color and mix it with pure
distilled water. Pour the water mix into the reservoir
via the water filling hole. Once the reservoir is 90%
full, turn on the power supply for the pump to run
and let the air exit the loop. Turn off the power
supply when the reservoir is near empty. Repeat until
all the air has exited the loop.
(In order to power the pump only, connect the power
switch connector to the 24 pin cable of the power
supply. This will allow the power supply to bypass
the motherboard and make the pump work alone.)
The warranty will be void if any of the situations below happen.
Water Block
- The CPU block and the screws in it has any trace of disassemble.
- The top plate inlet and outlet ports, due to improper use of external forces, are cracked.
Radiator
- The 󼴩n of the radiator are broken or deformed due to improper use of external forces.
- The inlet and outlet of the radiator are cracked due to improper use of external forces.
Fitting
- There are signs of damage caused by instrument clamping on the 󼴩ttings.
PUMP
- Pump damage from pump operation without any liquid.
- Pump damage caused by water leak on the pump's PCB.
- Water tank has been separated from the pump.
Fan
- Fan damaged by water leak.
G1/4 Screw plug
- If the plug, screw speci󼴩cation or thread are not up to standard, the screw can not be
locked. If you tighten the screw violently, the device will be damaged.
Product Warranty Rules
Not included
Both the front and the back
side of the reservoir have
a fill hole, choose the one
that suits you.
[ 4 ]
Assembly steps
step 1
step 3
step 2
ROG Hyperion GR701
(Not included)
Remove the side panels.
Method 1
Open the back cover.
Attach the Reserviors lock to the
reference position in the above
picture.
It is recommended to install
the water-exhaust fitting at
the lowest point of the water
cooling system.
Step 1
Unscrew the top of
the water-exhaust
󼴩tting.
Step 2
Replace with the water-exhaust part. When screwing in the
part, water will start to discharge, it is recommended to
connect tubing beforehand to control the water out󼴪ow.
Drain
BPTA-WDPGR701
M4x6 Screw
✓ ✓
✓ ✓
✓ ✓
✓ ✓
BPTA-EFW BPTA-EFW
Fitting+ Soft Tube
[ 5 ]
Accessories(additional purchases)
Recommended installation method
BPN-NLS360-F2PB
A
BPTA-CPUMS-SKI
B
BPTA-FX1812NT-3
C
BPTA-DOTFH1622
D
BP-NCCLT16AC-L500
E
A
B
C
D
EC
A
D
E
E
DE
D
D
DD
F
F
F
D
D
F
G
BPTA-90RE
F
GPU Water Block
G
H
I
D
E
BPTA-F95
H
BPTA-F64
I
H
D
F
[ 6 ]
Assembly steps
step 1
step 3
step 2
ROG Hyperion GR701
(Not included)
Remove the stand
Method 2
Attach the Reserviors lock to the reference
position in the above picture.
It is recommended to install
the water-exhaust fitting at
the lowest point of the water
cooling system.
Step 1
Unscrew the top of
the water-exhaust
󼴩tting.
Step 2
Replace with the water-exhaust part. When
screwing in the part, water will start to
discharge, it is recommended to connect tubing
beforehand to control the water out󼴪ow.
Drain
BPTA-WDPGR701
M4x6 Screw
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Fitting + soft tube BPTA-EFW
✓ ✓
C32-WTP
[ 7 ]
Accessories(additional purchases)
Recommended installation method
BPN-NLS360-F2PB
A
BPTA-CPUMS-SKI
B
BPTA-FX1812NT-3
C
BPTA-DOTFH1622
D
BP-NCCLT16AC-L500
E
A
B
C
D
E C
D
DE
F
F
G
BPTA-90RE
F
GPU Water Block
G
H
I
BPTA-F95
H
TA-GFALP4169-GS
I
F
F
BPTA-PAM
J
J
A
D
D
D
[ 8 ]
記得上角要放對應的 LOGO!
Notice
Before filling in the water, please make sure all the components are
installed correctly. To prevent any leakage which may damage the PC
components, please perform a 24-hour leaking test with only the pump
connected to the power supply.
Bitspower reserves the right to change the product design and
interpretations. These are subject to change without notice. Product
colors and accessories are based on the actual product.
When using leak tester on water cooling loop, in order to avoid product
damage due to excessive pressure, the input pressure should not exceed
0.5kg/cm2 (Bar). If the product is damaged due to excessive pressure, it
will be the fault of the customer. DO NOT use the leak teser when there is
water in the loop or the pump is running.
Bitspower recommends that customers use Bitspower Pellucid Coolant
for their coolant fluid. It is also recommended to use Bitspower Dye to
create any desired color. If the customer chooses di󼴨erent liquid coolants,
the resulting impurities may cause peeling of the coating on some of the
hardware, water channel blockage by built-up residue, improper operation
of the water pump, water tank tube breakage, and o-ring deformation
leading to leakage. Any issues related to the use of inappropriate liquid
coolants will be the responsibility of the customer.
[ 9 ]
記得上角要放對應的 LOGO!
使用說明書
配件
請接 1主板或 2 其他設備的 DRGB 插槽
主板
DRGB 控制器 ( 不包括 )
BPTA-DRGBMFC
12
Bitspower Sedna GR701 for
ASUS ROG HYPERION GR701 V2
BPTA-WDPGR701
1M4x6 螺絲 10 PCS 2BPTA-EFW-GS 1 PCS 3接頭 + 軟管 1 PCS
4BP-BB2WP-P02 1 PCS 5C32-WTP 1 PCS
[ 10 ]
供電與水泵
如果有需要
規格
額定電壓:12V DC
功耗:15W
最大流量:11±15% L/min
噪音:≤ 40dBA
PWM:有
平均壽命:15000 hours
保固:2 years
尺寸 : 62 x 62 x 46.7mm
水泵最大揚程 : 5.5±0.5m
※ 可通過調整孔位偏移塊的位置,以對應不同主機板的
CPU 安裝位置。
O 圈 (54×50×2mm)
水路導通模組
孔位偏移塊 (CPU)
M4×16mm 螺絲
O 圈 (60×56×2mm)
安裝 GPU 冷頭時,需要把水路導通模組拆除,然後安
裝相應的接頭即可使用。
G1/4 堵頭
所有管子連接孔均為 G 1/4 螺牙
導通
G1/4 螺牙堵頭
M4×16mm 螺絲 ※ 安裝冷排時,需要把導通模組拆除,然後安裝相應的接
頭即可使用。
[ 11 ]
注水
選擇喜好的水冷濃縮液顏色以純淨水調合由”填水孔”
注入至水箱九分滿接著利用”24PIN 跳線開關”啟動電源
讓水路中的空氣集中至水箱排出再依水量繼續添加至
水箱九分滿左右即可
24PIN 跳線開關用途需無經主板開啟 ATX 電源時使
電源直接開啟供電
質保期時效,送修的產品凡有以下狀況,不在保修範圍內。
水冷頭
- 冷頭自體螺絲,有拆裝痕跡,整套產品失保。
- 頂部的進出口,因為外力使用不當導致開裂。
冷排
- 因為外力使用不當導致冷排水道破裂漏水。
- 進出水孔因為外力使用不當導致開裂。
接頭
- 有器械夾持導致的損傷痕跡。
水泵
- 無水通電導致水泵燒毀。
- 底部 pcb 進水燒毀。
- 水箱底座與水泵不可拆解,一經拆解即不保固。
風扇
- 進水燒毀。
堵頭
- 堵頭、螺絲規格或牙紋不達標,會鎖不了孔位,暴力裝配致使破裂。
產品保修規範
未包括
正反面皆有注水孔,選擇適
用即可。
[ 12 ]
組裝步驟
步驟 1
步驟 3
步驟 2
步驟 4
ROG Hyperion GR701
( 不包括 )
拆下側面板
方法 1
打開後蓋
參考上圖鎖附水道板
建議將洩水接頭安裝於水冷系
統的最低點。
步驟 1
將洩水接頭上蓋旋起。
步驟 2
換上洩水配件,旋入配件過程中即會逐漸洩
水,建議外接管線以利洩水。
洩水
BPTA-WDPGR701
M4x6 螺絲
✓ ✓
✓ ✓
✓ ✓
✓ ✓
BPTA-EFW BPTA-EFW
接頭 + 軟管
[ 13 ]
主件說明 ( 需另購 )
建議安裝方式
BPN-NLS360-F2PB
A
BPTA-CPUMS-SKI
B
BPTA-FX1812NT-3
C
BPTA-DOTFH1622
D
BP-NCCLT16AC-L500
E
A
B
C
D
EC
A
D
E
E
DE
D
D
DD
F
F
F
D
D
F
G
BPTA-90RE
F
GPU Water Block
G
H
I
D
E
BPTA-F95
H
BPTA-F64
I
H
D
F
[ 14 ]
組裝步驟
步驟 3
ROG Hyperion GR701
( 不包括 )
拆下支架
方法 2
參考上圖鎖附水道板
建議將洩水接頭安裝於水冷系
統的最低點。
步驟 1
將洩水接頭上蓋旋起。
步驟 2
換上洩水配件,旋入配件過程中即會逐漸洩
水,建議外接管線以利洩水。
洩水
BPTA-WDPGR701
M4x6 螺絲
✓ ✓
✓ ✓
✓ ✓
✓ ✓
接頭 + 軟管 BPTA-EFW
✓ ✓
C32-WTP
步驟 1 步驟 2
BPTA-EFW
[ 15 ]
BPN-NLS360-F2PB
A
BPTA-CPUMS-SKI
B
BPTA-FX1812NT-3
C
BPTA-DOTFH1622
D
BP-NCCLT16AC-L500
E
A
B
C
D
E C
D
DE
F
F
G
BPTA-90RE
F
GPU Water Block
G
H
I
BPTA-F95
H
TA-GFALP4169-GS
I
F
F
BPTA-PAM
J
J
A
D
D
D
主件說明 ( 需另購 )
建議安裝方式
[ 16 ]
記得上角要放對應的 LOGO!
注意
跑水前,請先確認所有零件已安裝在正確的位置上,在不開主機,單開水
泵的情况下,進行 24 小時的跑水測試 確保無漏水情况後再開主機,避
免發生漏水而導致電腦零件的損壞。
本公司保留對產品的設計更改以及解釋的權力,如有更動恕不另行通知
產品顏色與配件以實物為準。
當使用測氣產品測試水路時,為避免由於壓力過大導致產品損壞,輸入的
壓力請不要超過 0.5kg/cm2 (Bar),如因壓力過大造成產品損壞,將由客戶
自行承擔,嚴禁客戶在水路有水及水泵開啟的情況下進行氣體飽壓測試。
Bitspower 使Bitspower 液。外,
Bitspower 染料到透明冷卻液中以滿足顏色要求。如果消費者選擇不同的
水冷液,可能會引起水路配件中的塗層剝落、積垢堵塞水道、水泵磨損
水箱管破裂、破壞 O 型圈密封性導致漏水等。任何因使用不當水冷液導致
相關的問題將由消費者自行負責。
[ 17 ]
記得上角要放對應的 LOGO!
使用说明书
配件
请接 1主板或 2 其他设备的 DRGB 插槽
主板
DRGB 控制器 ( 不包括 )
BPTA-DRGBMFC
12
Bitspower Sedna GR701 for
ASUS ROG HYPERION GR701 V2
BPTA-WDPGR701
1M4x6 螺丝 10 PCS 2BPTA-EFW-GS 1 PCS 3接头 + 软管 1 PCS
4BP-BB2WP-P02 1 PCS 5C32-WTP 1 PCS
[ 18 ]
供电与水泵
如果有需要
規格
额定电压:12V DC
功耗:15W
最大流量:11±15% L/min
噪音:≤ 40dBA
PWM:有
平均寿命:15000 hours
保固:2 years
尺寸 : 62 x 62 x 46.7mm
水泵最大扬程 : 5.5±0.5m
※ 可通过调整孔位偏移块的位置,以对应不同主机板的
CPU 安装位置。
O 圈 (54×50×2mm)
水路导通模组
孔位偏移块 (CPU)
M4×16mm 螺丝
O 圈 (60×56×2mm)
安装 GPU 冷头时,需要把水路导通模组拆除,然后安
装相应的接头即可使用。
G1/4 堵头
所有管子连接孔均为 G 1/4 螺牙
导通
G1/4 螺牙堵头
M4×16mm 螺丝 ※ 安装冷排时,需要把导通模组拆除,然后安装相应的接
头即可使用。
[ 19 ]
注水
选择喜好的水冷浓缩液颜色以纯净水调合由”填水孔”
注入至水箱九分满接着利用”24PIN 跳线开关”启动电源
让水路中的空气集中至水箱排出再依水量继续添加至
水箱九分满左右即可
24PIN 跳线开关用途需无经主板开启 ATX 电源时 使
电源直接开启供电
质保期时效,送修的产品凡有以下状况,不在保修范围内
水冷头
- 冷头自体螺丝,有拆装痕迹,整套产品失保。
- 顶部的进出口,因为外力使用不当导致开裂
冷排
- 因为外力使用不当导致冷排水道破裂漏水。
- 进出水孔因为外力使用不当导致开裂
接头
- 有器械夹持导致的损伤痕迹
水泵
- 无水通电导致水泵烧毁。
- 底部 pcb 进水烧毁。
- 水箱底座与水泵不可拆解,一经拆解即不保固。
風扇
- 进水烧毁
堵頭
- 堵頭、螺絲規格或牙紋不達標,會鎖不了孔位,暴力裝配致使破裂。
产品保修规范
未包括
正反面皆有注水孔,选择适
用即可。
[ 20 ]
组装步骤
步骤 1
步骤 3
步骤 2
步驟 4
ROG Hyperion GR701
( 不包括 )
拆下侧面板
方法 1
打开后盖
参考上图锁附水道板
建议将泄水接头安装于水冷系
统的最低点
步骤 1
将泄水接头上盖旋起。
步骤 2
换上泄水配件,旋入配件过程中即会逐渐泄
水,建议外接管线以利泄水。
洩水
BPTA-WDPGR701
M4x6 螺丝
✓ ✓
✓ ✓
✓ ✓
✓ ✓
BPTA-EFW BPTA-EFW
接头 + 软管
/