Bitspower BPTA-WDPO11DXLA-P5D インストールガイド

  • Bitspower Sedna O11DXL水冷システムの取扱説明書の内容を読み込みました。この製品の付属品、組み立て手順、使用方法、トラブルシューティングなどについてご質問があれば、お気軽にお尋ねください。
  • ポンプの電源供給方法は?
    エア抜き方法を教えてください。
    推奨される冷却液は何ですか?
    漏水テストの方法を教えてください。
[ 1 ]
instruction manual
Digital RGB PIN on 1motherboard
or 2other equipment.
motherboard DRGB Multi Function Controller
(Not included)
BPTA-DRGBMFC
12
Accessories
1
5
6
7
8
9
10
11
12
13
14
15
16
3
4
2
BPTA-WDPO11DXLA-P5D
Inside Ba󼴬e(Dowm)
Outer Ba󼴬e(Up)
M3x12 Screw
M3x8 Screw
Panel
BPTA-EFW
TA-EXAIR
M2.5x6 Screw
M3x10 Screw
M3 Nut
Nut
Washer
Outer Ba󼴬e(Dowm)
Inside Ba󼴬e(Up)
1 SET
1 PC
1 PC
6 PCS
2 PCS
1 PC
1 PC
1 PC
9 PCS
6 PCS
6 PCS
2 PCS
6 PCS
1 PC
1 PC
Bitspower Sedna O11DXL for
LIAN LI O11 DYNAMIC (front)-P5D V1
1 2
3PIN/4PIN Transfer4PIN 1 PC
[ 2 ]
Power Supply and Pump
Other then from the
motherboard, the
P5D pump can be
powered from the
power supply via a
patch cord.
Pump Spec
Rated voltage:12V DC
Power consumption:20W
Maximum 󼴪ow:14.5±15% L/min
Noise:≤ 40dBA
Ambient temperature:-25~70℃
PWM:Yes
MTBF:15,000 hours
Warranty:2 years
Press the button to release the
air.
It is recommended to install
the air-exhaust fitting on the
reservoir, above the water line.
It is recommended to install
the water-exhaust fitting at
the lowest point of the water
cooling system.
Replace with the water-
exhaust part. When screwing
in the part, water will start to
discharge, it is recommended
to connect tubing beforehand
to control the water out󼴪ow.
Unscrew the top of the water-
exhaust 󼴩tting.
BP-ETWTA-EXAIR
A:Negative electrode -
B:Positive electrode +
C:Speed signal
D:Speed control signal
A B C D
[ 3 ]
Water
Choose your desired dye color and mix it with pure
distilled water. Pour the water mix into the reservoir
via the water filling hole. Once the reservoir is 90%
full, turn on the power supply for the pump to run
and let the air exit the loop. Turn off the power
supply when the reservoir is near empty. Repeat until
all the air has exited the loop.
(In order to power the pump only, connect the power
switch connector to the 24 pin cable of the power
supply. This will allow the power supply to bypass
the motherboard and make the pump work alone.)
The warranty will be void if any of the situations below happen.
Water Block
- The CPU block and the screws in it has any trace of disassemble.
- The top plate inlet and outlet ports, due to improper use of external forces, are cracked.
Radiator
- The 󼴩n of the radiator are broken or deformed due to improper use of external forces.
- The inlet and outlet of the radiator are cracked due to improper use of external forces.
Fitting
- There are signs of damage caused by instrument clamping on the 󼴩ttings.
PUMP
- Pump damage from pump operation without any liquid.
- Pump damage caused by water leak on the pump's PCB.
- Water tank has been separated from the pump.
Fan
- Fan damaged by water leak.
Product Warranty Rules
[ 4 ]
Assembly steps
step 1
for BPTA-WDPO11DXLA-P5D
step 4
step 3
step 2
PC-O11 Dynamic XL
(Not included)
TOP
Dust shield
Glass plate
Front plate
Side plate
12
7
2
3
5
7
4
8 6
[ 5 ]
Recommended installation method for BPTA-WDPO11DXLA-P5D
BP-NLXF360-F4PB
BPTA-CPUMS-SKI
BP-VG2080RD
BP-EML14
BP-90R
BPTA-EXAIR
BP-WTP-C06
BPTA-DRGBMFC
BP-PFANMFH
BP-NCCLT14AC-L500
BP-WTP-C61
Accessories(additional purchases)
A
B
C
D
E
F
G
H
J
K
L
I
1PC
1PC
1PC
14PCS
8PCS
1PC
3PCS
1PC
1PC
4PCS
1PC
A
D
BI
E
E
E
E
E
F
F
F
H
H
H
G
E
IF
F
F
BP-DG14AALPII 2PCS
C
J
K
L
[ 6 ]
for BPTA-WDPO11DA-P5D
step 1
step 4
step 3
step 2
PC-O11 Dynamic
(Not included)
TOP
Dust shield
Glass plate
Front plate
Side plate
Panel
BPTA-WDPO11DA
The circled rivet need to
be removed manually
with a 3mm drill bit.
14
15
16
12
13
[ 7 ]
BPTA-NLSS360-F2PB
BPTA-CPUMS-DRGB
BP-VG2080RD
BPTA-FX2212
BP-DG14AALPII
BP-EML14
BP-90R
BP-TB
BP-WTP-C06
BP-WTP-C60
BP-NCCLT14AC-L500
BP-PFANMFH
BPTA-DRGBMFC
BP-RG
Accessories(additional purchases)
A
B
C
D
E
F
G
H
J
K
L
M
N
I
1PC
1PC
1PC
3PCS
2PCS
10PCS
6PCS
1PC
3PCS
1PC
4PCS
1PC
1PCS
1PC
A
B
C
D
E
F
G
H
I
J
K
L
N
M
Recommended installation method for BPTA-WDPO11DA-P5D
Notice
Before filling in the water, please make sure all the components are
installed correctly. To prevent any leakage which may damage the PC
components, please perform a 24-hour leaking test with only the pump
connected to the power supply.
Bitspower reserves the right to change the product design and
interpretations. These are subject to change without notice. Product
colors and accessories are based on the actual product.
When using leak tester on water cooling loop, in order to avoid product
damage due to excessive pressure, the input pressure should not exceed
0.5kg/cm2 (Bar). If the product is damaged due to
excessive pressure, it will be borne by the customer. Forbidden to use the
leak teser when there is water in the loop or the pump is runing.
Bitspower recommends that consumers add the Bitspower dye to distilled
water or purified water for their water-cooling liquid. If the consumer
chooses di󼴨erent water-cooling liquids, the resulting impurities may cause
peeling of the coating on some of the hardware, water channels blockage
by built-up residue, improper operation of the water pump, water tank
tube breakage, and o-rings deformation leading to leakage. Any issues
related to the use of inappropriate water-cooling liquid will be the
responsibility of the consumer.Do not turn on the pump if the reservoir is
empty.
[ 8 ]
記得上角要放對應的 LOGO!
[ 9 ]
記得上角要放對應的 LOGO!
使用說明書
Bitspower Sedna O11DXL for
LIAN LI O11 DYNAMIC (front)-P5D V1
請接 1主版或 2 其他設備的 DRGB 插槽
主版
DRGB 控制器 ( 不包括 )
BPTA-DRGBMFC
12
配件
1
5
6
7
8
9
10
11
12
13
14
15
16
3
4
2
BPTA-WDPO11DXLA-P5D
內固定夾板 ( 下 )
外固定夾板 ( 上 )
M3x12 螺絲
M3x8 螺絲
面板
洩水接頭
排氣接頭
M2.5x6 螺絲
M3x10 螺絲
M3 螺帽
手轉螺帽
墊片
外固定夾板 ( 下 )
內固定夾板 ( 上 )
1 組
1 個
1 個
6 支
2 支
1 片
1 個
1 個
9 支
6 支
6 個
2 個
6 個
1 個
1 個
1 2
大 4PIN 供電線材 1 個
[ 10 ]
供電與馬達
P5D 馬達除了可由主
機板供電外,亦可透
過轉接線由電源供應
器直接供電。
將按鈕按下即可排氣
建議將排氣接頭安裝於
水箱且在水位之上。
建議將洩水接頭安裝於水冷系統
的最低點。
換上洩水配件,旋入配件過程中
即會逐漸洩水,建議外接管線以
利洩水。
將洩水接頭上蓋旋起。
BP-ETWTA-EXAIR
水泵規格
額定電壓:12V DC
功耗:20W
最大流量:14.5±15% L/min
噪音:≤ 40dBA
環境溫度:-25~70℃
PWM:有
使用壽命:15,000 小時
保固:2 年
A
A: 電源負極 -
B: 電源正極 +
C: 轉速信號
D: 調速信號
B C D
[ 11 ]
水泵規格
額定電壓:12V DC
功耗:20W
最大流量:14.5±15% L/min
噪音:≤ 40dBA
環境溫度:-25~70℃
PWM:有
使用壽命:15,000 小時
保固:2 年
注水
選擇喜好的水冷濃縮液顏色以純淨水調合由”填水孔”
注入至水箱九分滿接著利用”24PIN 跳線開關”啟動電源
讓水路中的空氣集中至水箱排出再依水量繼續添加至
水箱九分滿左右即可
24PIN 跳線開關用途需無經主板開啟 ATX 電源時使
電源直接開啟供電
質保期時效,送修的產品凡有以下狀況,不在保修範圍內。
水冷頭
- 冷頭自體螺絲,有拆裝痕跡,整套產品失保。
- 頂部的進出口,因為外力使用不當導致開裂。
冷排
- 因為外力使用不當導致冷排水道破裂漏水。
- 進出水孔因為外力使用不當導致開裂。
接頭
- 有器械夾持導致的損傷痕跡。
水泵
- 無水通電導致水泵燒毀。
- 底部 pcb 進水燒毀。
- 水箱底座與水泵不可拆解,一經拆解即不保固。
風扇
- 進水燒毀。
產品保修規範
[ 12 ]
組裝步驟
步驟 1
步驟 4
步驟 3
步驟 2
PC-O11 Dynamic XL
( 不包括 )
頂蓋
防塵罩
玻璃板
前面板
側板
BPTA-WDPO11DXLA-P5D 參考
12
7
2
3
5
7
4
8 6
[ 13 ]
BPTA-WDPO11DXLA-P5D 建議安裝方式
BP-NLXF360-F4PB
BPTA-CPUMS-SKI
BP-VG2080RD
BP-EML14
BP-90R
BPTA-EXAIR
BP-WTP-C06
BPTA-DRGBMFC
BP-PFANMFH
BP-NCCLT14AC-L500
BP-WTP-C61
A
B
C
D
E
F
G
H
J
K
L
I
1PC
1PC
1PC
14PCS
8PCS
1PC
3PCS
1PC
1PC
4PCS
1PC
A
D
BI
E
E
E
E
E
F
F
F
H
H
H
G
E
IF
F
F
BP-DG14AALPII 2PCS
C
J
K
L
主件說明 ( 需另購 )
[ 14 ]
步驟 1
步驟 4
步驟 3
步驟 2
PC-O11 Dynamic
( 不包括 )
頂蓋
防塵罩
玻璃板
前面板
側板
面板
BPTA-WDPO11DA
紅圈處拉釘 , 需用 3mm
鑽頭手動電鑽去除
BPTA-WDPO11DA-P5D 參考
14
15
16
12
13
[ 15 ]
BPTA-NLSS360-F2PB
BPTA-CPUMS-DRGB
BP-VG2080RD
BPTA-FX2212
BP-DG14AALPII
BP-EML14
BP-90R
BP-TB
BP-WTP-C06
BP-WTP-C60
BP-NCCLT14AC-L500
BP-PFANMFH
BPTA-DRGBMFC
BP-RG
主件說明 ( 需另購 )
A
B
C
D
E
F
G
H
J
K
L
M
N
I
1PC
1PC
1PC
3PCS
2PCS
10PCS
6PCS
1PC
3PCS
1PC
4PCS
1PC
1PCS
1PC
BPTA-WDPO11DA-P5D 建議安裝方式
A
B
C
D
E
F
G
H
I
J
K
L
N
M
注意
跑水前,請先確認所有零件已安裝在正確的位置上,在不開主機,單開水泵的
情况下,進行 24 小時的跑水測試, 確保無漏水情况後再開主機,避免發生漏
水而導致電腦零件的損壞。
本公司保留對產品的設計更改以及解釋的權力,如有更動恕不另行通知,產品
顏色與配件以實物為準。
當使用測氣產品測試水路時 , 為避免由于壓力過大導致產品損壞 , 輸入的壓力
過 0.5kg/cm2 (Bar), 如因壓力過大造成產品損壞 , 將由客戶自行承
擔 . 嚴禁客戶在水路有水及水泵開啟的情況下進行氣體飽壓測試。
Bitspower 建議消費者使用蒸餾水、純凈水,加入 Bitspower 的染劑作為水冷
液使用;如客戶自行選購的水冷液導致電鍍層剝落、水道堵塞、水泵轉動不正
常、水箱管破裂或密封圈變型以致漏水等及其它不可抗力之問題時,消費者自
行承擔相關產品責任。未注水前,請勿啟動水泵電源。
[ 16 ]
記得上角要放對應的 LOGO!
[ 17 ]
記得上角要放對應的 LOGO!
使用说明书
Bitspower Sedna O11DXL for
LIAN LI O11 DYNAMIC (front)-P5D V1
请接 1主版或 2 其他设备的 DRGB 插槽
主版
DRGB 控制器 ( 不包括 )
BPTA-DRGBMFC
12
配件
1
5
6
7
8
9
10
11
12
13
14
15
16
3
4
2
BPTA-WDPO11DXLA-P5D
內固定夹板 ( 下 )
外固定夹板 ( 上 )
M3x12 螺丝
M3x8 螺丝
面板
泄水接头
排气接头
M2.5x6 螺丝
M3x10 螺丝
M3 螺帽
手转螺帽
垫片
外固定夹板 ( 下 )
內固定夹板 ( 上 )
1 组
1 个
1 个
6 支
2 支
1 片
1 个
1 个
9 支
6 支
6 个
2 个
6 个
1 个
1 个
1 2
大 4PIN 供电线材 1 个
[ 18 ]
供电与马达
P5D 水泵除了可由主
机板供电外,亦可透
过转接线由电源供应
器直接供电。
將按鈕按下即可排氣
建议将排气接头安装于
水箱且在水位之上。
建议将泄水接头安装于水冷系统
的最低点。
换上泄水配件,旋入配件过程中
即会逐渐泄水,建议外接管线以
利泄水。
将泄水接头上盖旋起。
BP-ETWTA-EXAIR
水泵規格
额定电压:12V DC
功耗:20W
最大流量:14.5±15% L/min
噪音:≤ 40dBA
环境温度:-25~70℃
PWM:有
使用寿命:15,000 小时
保固:2 年
A
A: 电源负极 -
B: 电源正极 +
C: 转速信号
D: 调速信号
B C D
[ 19 ]
注水
选择喜好的水冷浓缩液颜色以纯净水调合由”填水孔”
注入至水箱九分满接着利用”24PIN 跳线开关”启动电源
让水路中的空气集中至水箱排出再依水量继续添加至
水箱九分满左右即可
24PIN 跳线开关用途需无经主板开启 ATX 电源时 使
电源直接开启供电
质保期时效,送修的产品凡有以下状况,不在保范围内。
水冷头
- 冷头自体螺丝,有拆装痕迹,整套产品失保。
- 顶部的进出口,因为外力使用不当导致开裂。
冷排
- 因为外力使用不当导致冷排水道破裂漏水。
- 进出水孔因为外力使用不当导致开裂。
接头
- 有器械夹持导致的损伤痕迹。
水泵
- 无水通电导致水泵烧毁。
- 底部 pcb 进水烧毁。
- 水箱底座与水泵不可拆解,一经拆解即不保固。
风扇
- 进水烧毁。
产品保修规范
水泵規格
额定电压:12V DC
功耗:20W
最大流量:14.5±15% L/min
噪音:≤ 40dBA
环境温度:-25~70℃
PWM:有
使用寿命:15,000 小时
保固:2 年
[ 20 ]
组装步骤
步骤 1
步骤 4
步骤 3
步骤 2
PC-O11 Dynamic XL
( 不包括 )
顶盖
防尘罩
玻璃板
前面板
侧板
BPTA-WDPO11DXLA-P5D 参考
12
7
2
3
5
7
4
8 6
/