Notes and Warnings
NOTE:
A NOTE indicates important information that helps you make better use of your software.
DANGER:
A DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
WARNING:
A WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or
injury.
CAUTION:
A CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury or in property damage incidents.
DANGER:
Observe the following instruction to help prevent an imminently hazardous situation which, if not
avoided, will result in death or serious injury:
S
The U PS contains LETHAL VOLTAGES. All repairs and service should be performed by
AUTHORIZED SERVICE PERSONNEL ONLY.ThereareNO USER SERVICEABLE PARTS
inside the UPS or EBM.
Information in this document is subject to change without notice.
E 2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.; ENERGY STAR name is a registered trademark owned
by the U.S. Environmental Protection Agency.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their
products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
December 2012
3
System Features
|
System Features
Providing outstanding performance and reliability, the UPS's unique benefits include:
S
Online UPS design with pure sine wave output.
S
True online double-conversion technology with high power density, utility frequency
independence, a nd generator compatibility.
S
Buck and Boost voltage regulation that ensures regulated voltage to your load by correcting voltage
fluctuations.
S
The UPS filters and regulates incoming AC power and provides consistent power to your
equipment without draining the battery.
S
Selectable High Efficiency mode of operation.
S
5U UPS height.
S
Start-on-battery capability for powering up the UPS even if utility power is not available.
S
Maintenance is simplified by allowing the safe replacement of batteries without powering down the
UPS.
S
Dell service tag information can be read from the front panel LCD display.
S
Extended runtime with an optional Extended Battery Module (EBM).
S
Emergency shutdown control through the Remote Emergency Power-off (REPO) ports.
S
Two standard communication ports (USB and RS-232 serial port).
S
Optional Dell Network Management Card (also known as the NMC) with enhanced
communication capabilities for increased power protection and control.
S
Optional Environmental Monitoring Probe (EMP) for collecting temperature and humidity
readings in the frame environment and monitoring the environmental data remotely. You can also
collect and retrieve the status of two user-provided contact devices.
S
Advanced power management with the Dellt Multi-UPS Management Console (MUMC) and
Dellt UPS Local Node Manager (ULNM) Web-based software applications for graceful
shutdowns and power monitoring.
S
Sequential shutdown and load management through separate receptacle groups called load
segments.
S
Firmware that is easily upgradable without a service call.
S
Backed by worldwide agency approvals.
S
ENERGY STAR
®
certified UPSs.
4
|
Finding Information
Finding Information
CAUTION:
The Safety, Environmental, and Regulatory Information document provides important safety and
regulatory information.
What are You Looking For?
Find It Here
S The user's guide for my UPS
S The user's guide for the Dell Network Management
Card
S Dell MUMC and Dell ULNM User's Guides
NOTE:
Documentation and software updates can be
found at www.support.dell.com and at
www.dellups.com.
Dell UPS Disc
S Specifications
S How to configure UPS settings
S How to troubleshoot and solve problems
S How to install REPO control
Dell UPS User's Guide
The user's guide is available on the Dell UPS disc and
on www.support.dell.com.
S Safety instructions
S Regulatory information
S Recycling information
Safety, Environmental, and Regulatory Information
S Warranty information
S Terms and Conditions (U.S. only)
S End User License Agreement
Dell Warranty and Support Information
S Support information Dell Support Website www.support.dell.com
NOTE:
Select your region or business segment to view
the appropriate support site.
5
Installation and Startup
|
Installation and Startup
CAUTION:
Before performing the procedures in this document, read and follow the safety instructions and
important regulatory information in your Safety, Environmental, and Regulatory Information document.
CAUTION:
Unpacking the cabinet in a low-temperature environment may cause condensation to occur in and
on the cabinet. Do not install the cabinet until the inside and outside of the cabinet are absolutely dry (hazard
of electric shock).
CAUTION:
Installing or removing the battery trays should be performed or supervised by personnel
knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from
batteries.
6
|
Installation and Startup
CAUTION:
The cabinet is heavy (99 kg/218 lb): Always remove both battery trays from the UPS before lifting
the cabinet. Lifting the cabinet into the rack requires a minimum of two people.
CAUTION:
The batteries are heavy (32 kg/71 lb). Use proper lifting techniques when removing the batteries.
NOTE:
Use care when moving and opening the carton. Leave the components packaged until ready to install.
This section describes the steps to set up your system for the first time.
Unpacking the Cabinet
To unpack the system:
1
Using a forklift or pallet jack, move the shipping carton and pallet near the rack where you will
install the UPS.
2
Detach and remove the outer carton.
7
Installation and Startup
|
3
Remove the two accessory boxes tucked into the channels in the top Styrofoam section.
4
Open the accessory boxes and set them on a flat, stable surface nearby.
NOTE:
The Dell Online Rack UPS 10 kW User's Guide provides unpacking and installation procedures. To refer
to it, remove it from the accessory box before you set the accessory boxes aside.
5
Remove the top Styrofoam section and set it on a flat, stable surface nearby.
8
|
Installation and Startup
NOTE:
The battery retaining brackets are labeled L (Left) and R (Right) to indicate where they must be installed.
6
Remove both retaining brackets from the UPS:
Locate the left (labeled L) retaining bracket. On the left side of the chassis, turn the thumbscrew
counter-clockwise to release the left retaining bracket.
Push the bracket toward the center post to disengage it from the chassis. Swing the bracket toward
you and pull the bracket to the left to remove it. Set the bracket aside.
Locate the right (labeled R) retaining bracket. On the right side of the chassis, turn the
thumbscrew counter-clockwise to release the right retaining bracket.
Push the bracket toward the center post to disengage it from the chassis. Swing the bracket toward
you and pull the bracket to the right to remove it. Set the bracket aside.
7
Ensure all battery connectors are disconnected.
9
Installation and Startup
|
CAUTION:
The batteries are heavy (32 kg/71 lb). Use proper lifting techniques when removing the batteries.
8
Remove the battery trays from the UPS:
Move the disconnected UPS battery connectors at the top of the battery compartment out of the
way.
Grip the two plastic loop tabs on the front of the battery tray. Pull the tray toward you to remove.
NOTE:
The orange PULL HERE labels indicate where to grasp the loop tabs.
Set the battery tray on the Styrofoam section you removed from the top of the UPS.
Repeat with the second battery tray.
10
|
Installation and Startup
CAUTION:
The cabinet is heavy (46 kg/101 lb) with the batteries removed. Lifting the cabinet from the
shipping carton requires a minimum of two people.
9
With one person on each side, carefully lift the cabinet out of the styrofoam using the handles on
the cardboard.
10
Place the cabinet on a flat, stable surface in a protected area near the rack where you will install it.
NOTE:
Ensure that the area has adequate airflow and is free of humidity, flammable gas, and corrosion.
11
Installation and Startup
|
Rackmount Setup
CAUTION:
The cabinet is heavy (99 kg/218 lb). Always remove both battery trays from the UPS before lifting
the cabinet and installing the UPS on the rails in the rack. Lifting the cabinets into the rack requires a
minimum of two people.
CAUTION:
Installing or removing the batteries should be performed or supervised by personnel
knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from
batteries.
CAUTION:
The batteries are heavy (32 kg/71 lb). Use proper lifting techniques when removing the batteries.
CAUTION:
If installing an optional EBM, the EBM must be located below the UPS with no U space between
the UPS and EBM. This provides better weight distribution in the rack, easier access to the UPS control panel,
and easier routing for the battery cable connections. This also prevents strain between the EBM cord and the
UPS connection and possible connection failure.
WARNING:
For Rack-Mounted Systems: When installing multiple systems in a rack, complete all of the
procedures for the current system before attempting to install the next system.
NOTE:
Mounting rails are required for each individual cabinet.
NOTE:
The cabinet is shipped without the front cover bezel attached.
NOTE:
The following instructions are the same for square-hole racks and unthreaded, round-hole racks. The
rails fit both rack styles.
To install the UPS in a rack:
1
Ensure that the following are placed on a flat, stable surface near the rack where you will install
the UPS:
S
cabinet
S
two UPS accessory boxes
S
two battery trays (UPS only)
S
two battery retaining brackets (UPS only)
12
|
Installation and Startup
Installing the Rails
2
Remove the rails from the rail kit accessory box.
3
Select the proper holes in the rail for positioning the cabinet in the desired location in the rack.
Locate the rails at the bottom of the 5U space allocated for the UPS.
CAUTION:
If installing an optional EBM, make provision for installing the EBM directly below the UPS with
no U space between the UPS and EBM.
NOTE:
Observe the labels on the rails for right front (labeled RIGHT FRONT) and left front (labeled LEFT
FRONT). This is the way the rails should be positioned for installation.
4
Position the left and right rails as illustrated. Attach the the left and right rails to the rack:
Engage the back end of the rail until it fully seats on the vertical rack flange and the hook latch
locks i n place.
Pulltherailjustpastthefrontoftherack.
Push the front end of the rail until it fully seats on the vertical rack flange and the hook latch locks
in place.
13
Installation and Startup
|
Installing and Securing the Cabinet
CAUTION:
The cabinet is heavy (46 kg/101 lb) with the batteries removed. Lifting the cabinet into the rack
requires a minimum of two people.
5
Slide the cabinet onto the rails and into the rack.
6
Secure the front of the cabinet to the rack using the four thumbscrews on the mounting brackets.
Tighten the thumbscrews clockwise by hand; do not use power tools.
Installing the Battery Trays
7
Locate the battery trays you placed near the rack.
14
|
Installation and Startup
CAUTION:
The batteries are heavy (32 kg/71 lb). Use proper lifting techniques when installing the batteries.
NOTE:
The battery trays can be installed in either battery compartment.
NOTE:
Insert the tray with the caution label arrow pointing upward.
8
Install the battery trays:
Move the UPS battery connectors at the top of the battery compartment out of the way.
Slide the battery tray into the battery compartment completely.
Repeat to install the second battery tray.
9
Tuck the loop tabs into the plastic sleeve on the front of each battery tray to move them out of the
way.
Connecting Internal Battery Connectors
10
Connect the internal battery connectors:
Connect the far-left battery tray connector to the f ixed UPS connector. Connect the far-right
battery tray connector to the fixed UPS connector.
NOTE:
A small amount of arcing may occur when connecting the batteries. This is normal and does not
damage the unit or present any safety concern.
Locate and connect the battery jumpers located on either side of the center post. Place the
connectors on the small shelf at the top of the center post.
NOTE:
Connecting the center battery jumpers connects the two battery trays serially.
15
Installation and Startup
|
Replacing the Battery Retaining Brackets
Center Post Side Channel
Chassis Side Channel
NOTE:
The battery retaining brackets are labeled L (Left) and R (Right) to indicate where they must be installed.
11
Replace the left (L)and right (R) battery retaining brackets:
For the first battery retaining bracket, insert the bracket tab into the channel on the side of the
center post. Fit the connected battery cables snugly behind the retaining bracket.
Align the end of the battery retaining bracket wi th the channel on the side of the chassis. Push the
bracket until it is firmly seated into the side channel.
Turn the thumbscrew clockwise to secure the bracket.
Repeat to replace the second battery retaining bracket.
Installing the UPS Front Cover
12
Remove the front cover f rom the accessory box.
16
|
Installation and Startup
NOTE:
Keep the software CD, communication cable, and (if needed) REPO connectors in the accessory box
until you install the UPS.
1
2
13
Install the UPS front cover:
Align the front cover with the front of the chassis.
Insert the right-side tabs on the front cover into tab openings on the right-side chassis.
Push the left side of the cover forward and snap it to the chassis.
NOTE:
Ensure that the LCD panel on the UPS chassis aligns with the LCD window on the front cover before
securing the cover to the chassis.
14
Discard or recycle the packaging in a responsible manner, or store it for future use.
17
Installation and Startup
|
Connecting the Equipment
To install the UPS:
1
If you plan to use Dell MUMC and Dell ULNM software, establish communication in one of the
following ways:
S
using the Dell Network Management Card (if installed)
S
using the supplied cable to connect your computer to the USB port
NOTE:
For more information about communication options, refer to the Dell Online Rack UPS 10 kW User's
Guide.
2
If your rack has conductors for grounding or bonding of ungrounded metal parts, connect the
ground cable (not supplied) to the ground bonding screw. See “UPS Rear Panels” on page 24 for
the l ocation of the ground bonding screw for each of the three models.
3
If an emergency power-off (disconnect) switch isrequiredbylocalcodes, refer to “Installing
Remote Emergency Power-off” in the Dell Online Rack UPS 10 kW User's Guide.
4
If you are installing an optional EBM, refer to the Dell Online Rack EBM 10 kW Getting Started
Guide for installation instructions.
CAUTION:
If the UPS is stored or used without an EBM, the battery connector cover on the rear panel of the
UPS must be installed as a safety precaution.
5
Plug the equipment to be protected into the UPS output receptacles, but do not turn on the
protected equipment.
6
Make any necessary provisions for cord retention and strain relief.
NOTE:
Verify that the total equipment ratings do not exceed the UPS capacity to prevent an overload alarm.
18
|
Installation and Startup
Hardwiring the UPS Input
WARNING:
Risk of electrical shock. Only qualified service personnel (such as a licensed electrician) shall
perform the electrical installation.
The Dell Online Rack hardwired models require a dedicated branch circuit that meets the following
requirements:
S
Protection device requires a two-pole disconnection device between the UPS input and the mains
S
Breaker must be wall-mounted and be readily accessible to the operator
S
For Europe. Breaker must meet the IEC/EN 60934 standard and at least 3 mm contact air gap
S
200–240 Vac
S
Single-phase
S
50/60 Hz
S
Flexible metal conduit (recommended for ease of service and maintenance)
AC Mains
Wall
2-pole
Breaker
UPS
Line
Neutral/L2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244

Dell UPS 10000R クイックスタートガイド

タイプ
クイックスタートガイド