Pro'sKit MT-7071N 取扱説明書

タイプ
取扱説明書
1
MT-7071N
LCD Cable Length Toner & Probe Kit
Users Manual
1st Edition, 2023
©2023Copyright by Prokit’s Industries Co., Ltd.
2
1. OVERVIEW
Thank you for purchase Pro’sKit MT-7071N LCD Cable Length
Toner & Probe Kit. The Toner and Probe set is used to measure
cable length and quickly trace and identify cables or wires within a
group and also check the operation of telephone lines. With proper
use and care, this instrument will provide many years of reliable
service.
MT-7071N is a new high-frequency filter circuit technology, with the
elimination of noise and anti-interference line tracker, LCD display
screen. Users can select display language in Chinese or English.
Suitable for ordinary network, PoE network, UTP / STP cable search
and positioning. The interface on the network can be located through
the port flashing function. Network Cable and BNC coax map test.
This product can perform the network wire length testing. This
product is suitable for telecommunications, network communication,
monitoring, CATV and other indoor and outdoor wiring construction
or maintenance projects.
Caution
!This product uses 9V 6LR61 or 6F22 battery power supply, and
6LR61 battery is recommended.
!To save the battery, please shut down immediately after use. If it
is not in use for a long time, please remove the battery in the
transmitter and receiver to avoid damage to the product caused by
battery liquid from leaking out.
!This product is strictly prohibited to access the live lines above
voltage DC 60V or any AC voltage.
!Please do not perform related operations on the communication
line during thunderstorms to prevent lightning strikes and personal
safety.
!Do not place this product in dusty, wet and temperatures above
40.
!Please do not disassemble the device. Repair and maintenance
should be done by a professional staff.
3
2.Diagram
Transmitter and Remote Unit Diagram
RJ45(with LED) connectorFor Cable Length and Port Flash test
RJ45 connectorFor Cable mapCable Tracing.
BNC connector: For Coax mapCoax Tracing
LCD display.
keyENTER key: Press this key for a test choose or setting.
keyPress this key to move arrow cursor up or left on LCD
to choose function.
keyPress this key to return to previous menu.
Press this key to power on, and long push again for power
off.
Press this key to move arrow cursor down or right on LCD
to choose function.
Battery cover.
4
Receiver Diagram
ProbeUsed for cable tracing and NCV detection.
LED light
Power ON/OFF indicator
NCV indicator
Signal status indicator
Sensitivity control
Earphone socket (Φ3.5mm)
Function switch (LED light/NCV/OFF/SCAN mode)
Speaker
Locating and tracing cables function button
RJ45(8 pin)/ RJ11 (6/4/2 pin) cable mapping test
socket.
Battery cover
5
3.Operation
Do not connect with DC voltage over 60V or any AC
voltage live circuit equipment or it will result damage.
Press “ ”key to power on, as show blow. Press“ ” or“ ”key
to choose function. Press“ ”key to test. Press“ ”key to return.
Note: The arrowon the LCD display indicates the test port
location of the network cable to be tested.
graph 1 graph 2
Graph 1: The cable shall be inserted into the middle RJ45 connector.
Graph 2: The cable shall be inserted into the left RJ45(with LED)
connector .
3.1 Cable map test
Ø Insert the pending network cable into the transmitter RJ45 socket in
the middle and the other end into the receiver socket or remote unit,
BNC coax into BNC socket.
Ø Select the “CONT” menu and press “ ” to test with test results
shown below:
UTP STP
!"#$%
Type:Ca t5e/6/6a
Press ENTER Test
Type:Cat.5e/6/6a
Start Test
Un it : Meter
Le ngth
6
Short disconnection crossover
Ø Telephone cable test results shown below:
6p6c 6p4c 6p2c
Ø BNC coax test results shown below:
Ø If the display "cable open " indicates that the network jumper is all
open or the other end of the network cable is not inserted in the test
remote or receiver, or the test interface is wrong.
3.2 Measure Cable Length
During the test, the power consumption is large and the
battery power decline is fast. the test time should be interval
until the battery power is restored.
Ø Insert the pending network cable into the transmitter socket in the
left. Do not plug in any socket at the other end.
Ø Select the “Length” menu and press “ ” to test with test results
shown below:
CONT
7
Ø Units of length can select “Meter“Yard”Footunder the Units
menu.
Ø Because each pair of wire has different twisted density, it is normal
to measure the numbers slightly different, which can be measured
many times to get the same measurement value.
Ø From the image, it means there exists problem at 12.1m. To make
sure it is short or broke there, you can test it continuity to know
details.
NOTE: Kind reminds when measuring cable length.
1. The network cable to be tested must be de-energized.
2. Disconnect the cable at the far end, no remote, no other
devices connected!
3. The range must be 2.5m200m, otherwise , it would be
display 0 meter.
3.3 Cables tracking
Ø Connect one end of the target cable to the RJ45 socket in the
middle of the transmitter, BNC coax into BNC socket.
Ø Select the “SCAN” menu and press “ ” to transmit and shown
below:
Typ e:Cat.5e/6/6a
Start Te st
Un it : Meter
Le ngth
8
Ø The receiver function switch is switched on to the "Scan" or
"lighting" position.
Ø The receiver sensitivity knob is rotated clockwise to the maximum
(the arrow tail is above).
Ø Press and hold the "SCAN" button in the middle of the receiver,
while the probe is close to the network cable to be measured, the
speaker emits a clear "beep-beep " sound, and the network cable
contacted by the receiver probe is the target network cable to find.
Ø When tracking a cable in the working network, due to the network
switch, there may be audio signals adjacent to the target cable,
each cable can be removed to find the target cable or try to rotate
the receiver sensitivity knob counterclockwise to reduce the
reception sensitivity to find the target cable.
3.4 Port Flash & Switch details testing:
This function transmits the pulsing signal through the transmitter to
flashing the LED indicator of the network switch, then can locate the
interface of the network cable on the switch. At the same time, the
network switch working performance can be tested.
Do not connect with DC voltage over 60V or any AC
voltage live circuit equipment or it will result damage.
9
Ø Insert the network cable into the transmitter socket in the left.
Ø Select the “Flash” menu and press “ ” to start testing.
Ø The 2 indicators on the RJ45 jack port will be lit and flash. Then
observe the ports on switch, if there is a port whose flash frequency
is 3 secs, and slower than all the other ports, it tells you the port is
target one you’re looking for.
Ø Also, the device can tell you the connected switch’s information,
such as its speed (10M/100M/1000M), transmitting modes (FDX:
full duplex/ HDX: half duplex) Protocol (Auto- Nego / Non-Auto-
Nego). See the graph for ref. as below.
Ø If "Check Port" is displayed, the reasons may be: 1. Network cable
insertion error and test interface; 2. Network cable is not connected
to the switch; 3. Network cable fault. 4. Switch, router fault or
incompatibility with the instrument. 5. This instrument fails.
3.5 Setting:
This function can set the language (Chinese / English), backlight time,
automatic shutdown time, contrast, etc.
Ø Select the “Setting” menu and press “ ” to start setting.
Ø Backlight setting:
Adjust the backlight time among 5S, 10S, 15S, on and off.
Ch eck Port
&'(()*+
,
10
Ø Auto-off time setting:
Adjust the Auto-off time among 15mins, 30mins, 1hour, off.
Ø Contrast setting:
Press the ” to setting. And press or
key to adjust the contrast to suit yourself.
Ø Version information:
To c he c k v e rs io n in f or ma t io n o f so ftw a re a n d ha r dw a re . a s a bo v e.
3.6 Non-contact Voltage detection (NCV)
This function is used to determine whether the wire or equipment has
an AC voltage, the detection range AC90-1000V (50 / 60Hz).
Ø Push the receiver function switch to the NCV position, put the
receiver probe close to the target body, if the AC voltage is
detected, the speaker emits an alarm sound of different frequency,
the speaker rapid sound indicates a high voltage or fire line, the
slow sound may be low voltage or zero line.
-
./0
11
Note:
l This function is for reference, the voltage may still remain even
there is no detection showed up. There are many possible
factors might block the detection.
l There are external sources (like flashlight and motor) may trigger
non-contact voltage detection.
3.7 Flashlight
Ø Push the receiver switch to the position, and the front LED
auxiliary lighting LED is turned on for lighting with insufficient light.
Ø Only for lighting in the case of insufficient light, do not use it for a
long time to save the battery.
4. Battery Replacement
Ø When the battery symbol on the transmitter display is low, replace
the battery. When the receiver power indicator flashes, the battery
is low, replace the battery.
Ø The battery is 6F22 or 6LR61 9V battery, and the better
performance 6LR61 alkaline battery is recommended.
Ø Turn off the Transmitter or Receiver and disconnect all test
leads before replacing the battery.
Ø Properly install in the case to power the Transmitter and
Receiver.
12
5. Accessories
Parts
QTY
Parts
QTY
Transmitter
1
RJ45RJ45 Cable
2
Receiver
1
RJ45- alligator clips
1
Remote Unit
1
User Manual
1
Earphone
1
Storage bag
1
6.Specification
MT-7071N Transmitter Specifications
LCD 128×64 Dots (50×27.5mm)
ChineseEnglish
RJ45 × 2BNC × 1
9V: 6LR61 or 6F22
Cable Type
CAT.5E; CAT.6; CAT.6A; CAT.7
cableTelephone cableBNC coax
Max range
300m
Display
LCD: R&M 1-8/G
Cable Type
CAT.5E; CAT.6;cableTelephone
cable
Range
2.5m200m
Unit
meters/ yards / feet, selectable
option
Accuracy
±5%
Cable Type
CAT.5E; CAT.6; CAT.6A; CAT.7
cable; telephone cableBNC coax
Scan range
600 m
Frequency
455KHz
Max.
Signal
9±1Vp-p
13
Voltage
Flash
frequency
3sec/time
Link test
10M/100M/1000M; FDX/HDX; Auto-
Nego/Non-Auto Nego.
5s/10s/15s/on/off
15min/30min/1 hour/off
≤150mA
≤60V DC
138 × 80 × 35mm
MT-7071N Receiver Specifications
4 positions
1
455KHz
≥85dB
Elimination of noise
1 mode
knob-operated control
LED ×3
LED×1
RJ45× 1
Φ3.5mm×1
9V: 6LR61 or 6F22
≤100mA
14
202 × 50 × 32mm
Remote Unit Specification
RJ45× 1BNC× 1
106×32×30mm
7. MAINTENANCE & TROUBLE SHOOTING
Warning:
• Turn off the Transmitter or Receiver and disconnect all test leads
before replacing the battery.
Caution:
• To avoid damaging the case, do not use solvents or abrasive
cleansers. Clean the case with a soft cloth dampened with water or
a mild soap solution.
Trouble shooting
Possible Problems
Trouble shooting
The signal from
Transmitter can not be
detected by receiver
1. Shortage of battery power: Check
the battery on both Transmitter and
receiver. If the battery voltage is less
than 7.0V, please replace new battery
2. Make sure the switch position on
receiver is “SCAN” or “LED”. The
SCAN function will not work if the
switch is at “NCV” position.
3. Device damaged: please return the
product to the place you purchased
the product for maintenance
No signal received
from Transmitter on
Live
There might be conflict between the
signal from telephone office and the
15
telecommunication
device testing
signal from Transmitter. Please turn
off the telephone exchange device.
Incorrect cable
mapping result
LCD display broken: please return the
product to the place you purchased
the product for maintenance.
Improper connection of networking or
telephone cables: please reconnect
the cables to RJ45 or BNC individual
jacks.
Others
Device damaged: please return the
product to the place you purchased
the product for maintenance.
16
MT-7071N LCD 音頻線長查線器使用說明書
感謝購買和使⽤ MT-7071N LCD ⾳頻線⾧查線器,使⽤本儀器前請仔細
閱讀說明書並注意如下事項,閱後請妥善保存,以備⽇後查閱。
注意事項:
●本產品使⽤ 9V 6LR61 或 6F22 電池供電,推薦使⽤ 6LR61 電池。
●為節省電池,使⽤完畢請⽴即關機。如⾧時間不使⽤,請取出發射器
和接收器內的電池,以免電池漏液造成產品損壞。
●本產品嚴禁接⼊超過保護電壓 DC 60V 或任何交流電壓的帶電線路使⽤
●雷⾬天切勿進⾏通信線路操作,以防雷擊,造成設備或⼈⾝傷害。
●不要將此產品⾧時間暴露在陽光直射之下。
●不要將此產品放置在多塵、潮濕及超過 40℃溫度的地⽅。
●請勿隨便拆卸此產品,維修應由專業⼈員進⾏。
⼀、产品特点概述:
MT-7071N LCD ⾳頻線⾧查線器,LCD 液晶顯⽰,中⽂/英⽂語⾔選
介⾯。具有抗⼲擾⾳頻尋線對線測試導通、 短路、斷路、交叉)
網線線⾧測試(2.5-200 ⽶)端⼜閃爍並檢測網絡交換機性能等功能;可
設置:背光點亮時間、⾃動關機時間、⾧度單位 ⽶/英呎/碼等,可以接
⼊普通網絡交換機、PoE 網絡交換機帶電尋線。本產品適⽤於網絡
線、網絡維護與故障排查等
17
⼆、產品⽰意圖
發射器及測試端產品⽰意
RJ45(LED)插座:網線線⾧測試、端⼜閃爍測試插座
RJ45 插座對線、尋線測試插座
BNC 同軸尋線、對線測試插座
LCD 顯⽰
“ ” 確定ENTER進⾏測試選擇或設
“ ”向上向左
“ ”返回 RETURN
“ ”開/關機機;⾧,關機
“ ”鍵下或向右移
電池
18
發射器及測試端產品⽰意
⾳頻接收探頭
輔助照LED
源指
NCV 觸驗
尋線功能
靈敏調旋鈕
⽿插座
關:從上到依次 LED /NCV/OFF/SCAN
揚聲
SCAN:尋線時按住,接收信鬆開,不接收信
RJ45:對線測試使⽤
電池
19
三、使⽤說明
按“ ”鍵開機,進⼊如下⾯,按“ ”鍵選擇單,
進⾏測試,按“ ”鍵返回
注意:LCD 顯⽰屏上箭頭“”指⽰測試網線接位置:
測網線應⼊中間插座 測網線應左側插座
對線:⽤於檢測網絡情況故障判斷,如斷路”“交叉”“
等。
⾧度:⽤於檢測網線、電線⾧度,測量範圍 2.5-200 ⽶,只需網線
⼊發射器左側 RJ45 插座另外⼀端不可接測試端、接
收器或任何網絡接⼜,不可帶電測否則可能燒毀儀器
尋線:需配合⾳頻接收器⼀起使⽤,⽤於尋找⽬標網線發射器發射⾳
頻信,接收器接收信
閃爍:⽤於查找⽬標網線另外⼀端在交換機對應的接⼜,發射信使
交換機接⼜閃爍,時測試交換機作性能:10M/100M/1000M
半雙⼯/全雙⼯;⾃協商/協商等。
設置:設置發射器功能參數,可設置語⾔(中⽂/英⽂),背光時間,⾃
動關機時間,對度等。
类型:网络线
按下ENTER测试
20
3.1 對線測試:
Ø 測網絡線或電話跳分別插⼊發射器中間 RJ45 插座
和測試端或接收器 RJ45 插座BNC 跳線插入 BNC 插座。
Ø ⾳頻發射器選擇對線”菜單,按“ 進⼊測試單,按“
”鍵選擇測試類型網絡線 BNC ,確認按“ 進⾏測
試,測試結果如下顯⽰:
正常連 UTP STP
短路 斷線 交叉
Ø 網絡故障顯⽰,優先顯⽰短路狀況有短路故障時,斷線及交
故障不顯⽰,斷線和交叉故障時顯⽰。
Ø 接如下
6P6C 6P4C 6P2C
Ø BNC 接如下
Ø 如顯⽰纜開路或未連”表⽰網絡全部開路或網線另外⼀
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Pro'sKit MT-7071N 取扱説明書

タイプ
取扱説明書

他の言語で