Philips Thermometer SCH540 ユーザーマニュアル

カテゴリー
デジタル体温計
タイプ
ユーザーマニュアル

このマニュアルも適しています

SCH540
2
3
1 2 3 4
5
6 7 8
4
SCH540
ENGLISH 6
繁體中文 19
简体中文 30
6
Introduction
Congratulations on your purchase and welcome to Philips AVENT! To
fully benet from the support that Philips AVENT offers, register your
product at www.philips.com/welcome.
The Philips AVENT Digital Thermometer Set accurately and conveniently
measures your baby’s body temperature orally, axially and rectally. The
regular soother and the soother thermometer are suitable for use with
children aged 0-12 months. The digital exible-tip thermometer is suitable
for children and adults of all ages.
The unique combination of a soother thermometer and a digital, exible-
tip thermometer offers you the choice of adapting the temperature
measurement method to suit your baby.
The storage box contains three items:
- A soother thermometer to reliably measure your baby’s temperature.
It is very convenient to use and comfortable for your baby.
- A regular Freeow soother to let your baby get used to the shape.
- A digital exible-tip thermometer to measure your baby’s body
temperature axially or rectally if you want additional reassurance.
Make sure you follow the safety guidelines when using these items so that
you do not expose your child to any risk.
Use the soother thermometer to obtain a temperature indication. Use
the exible-tip thermometer to determine the actual body temperature.
If in any doubt, consult your doctor.
Important
General
- The symbols on the thermometers have the following meaning:
1 This symbol indicates that you have to read the user manual carefully
before you use the appliance. Save the user manual for future
reference (Fig. 1).
2 This symbol is to identify a type BF applied part complying with
IEC60601-1 (Fig. 2).
For your child’s safety WARNING!
- Never attach ribbons or cords to a soother, your child may be
strangled by them.
ENGLISH
- Inspect carefully before each use, especially when the child has teeth.
Pull the soother in all directions. Throw away at the rst signs of
damage or weakness.
- Do not leave a soother in direct sunlight or near a source of heat, or
leave in disinfectant (“sterilising solution”) for longer than
recommended, as this may weaken the teat.
- Keep the removable protection (cap) for the teat away from children
to avoid suffocation.
- Before rst use, place in boiling water for 5 minutes, allow to cool,
and squeeze out any trapped water from the soother. This is to
ensure hygiene.
- Clean before each use.
- Never dip teat in sweet substances or medication, your child may get
tooth decay.
- Replace the soother after 4 weeks of use, for safety and hygiene
reasons.
- In the event that the soother becomes lodged in the mouth, DO
NOT PANIC; it cannot be swallowed and is designed to cope with
such an event. Remove from the mouth with care, as gently as
possible.
- Always use this product under adult supervision. Keep in a dry
covered container. Soothers and caps are suitable for all commonly
used forms of sterilisation. Wash your hands thoroughly and ensure
surfaces are clean before contact with sterilised components.
- The soother can be cleaned by washing with warm water.
- DO NOT use abrasive cleaning agents or anti-bacterial cleaners on
the soothers. Excessive combinations of detergents may eventually
cause plastic components to crack. Should this occur, replace your
soother immediately.
- DO NOT sterilise the display case.
- For further advice on cleaning see chapter ‘Cleaning’.
Warning
- Do not immerse the measurement unit of the soother thermometer
in water or any other liquid. Never sterilise or boil the measurement
unit.
ENGLISH 7
- Never leave your child when you are measuring its temperature with
the soother thermometer or the exible-tip thermometer.
- The thermometers are not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given
supervision or instruction concerning use of the thermometers by a
person responsible for their safety.
- Children should be supervised to ensure that they do not play with
the thermometers.
- Never use the soother thermometer measurement unit separately to
avoid injury.
- Never use the soother thermometer as a regular soother.
- Battery compartment covers must be replaced properly if removed. If
loose, they may choke your child.
Caution
- Do not leave the soothers in disinfectant (‘sterilising solution’) for
longer than recommended, as this may weaken the teat.
- Do not drop the thermometers or expose them to shocks.
- Do not bend or disassemble the measurement unit of the
soother thermometer or the tip of the exible-tip thermometer
- Do not use the thermometer if the display shows the battery symbol.
This means that the battery is low and the measurements will be
inaccurate.
- Only use these thermometers to measure human body
temperatures.
- When not in use, store the soother, the soother thermometer and
the exible-tip thermometer in the storage box supplied.
- Do not use this Philips AVENT soother thermometer in combination
with parts of the old Philips soother thermometer (SCH530).
Electromagnetic elds (EMF)
These Philips AVENT thermometers comply with all standards regarding
electromagnetic elds (EMF). If handled properly and according to the
instructions in this user manual, the thermometers are safe to use based
on scientic evidence available today.
ENGLISH8
Before rst use
Clean the soother, soother thermometer and the exible-tip
thermometer before rst use. See chapter ‘Cleaning’.
Using the appliance
Ways to use the thermometers
The most convenient way to measure your baby’s temperature is to use
the soother thermometer according to this user manual. This method
gives a reliable indication. If you need additional reassurance (for example
if the rst measured temperature is above 38°C), you can then use the
digital exible-tip thermometer to take an axial (underarm) or a rectal
(anal) measurement.
Note: Oral measurements are usually 0.5 to 1°C lower than the actual body
temperature.
Childrens’ temperature
The temperature of a child is normally between 36.5 and 37.5°C.
However, you have to keep in mind that a child’s temperature varies
depending on age, activity, time of day, etc. Also remember that some
illnesses do not have high temperature as a symptom.Temperature
measurement should not be a substitute for consulting your physician.
When reporting your child’s temperature to a professional, state the
measurement method.
Soother thermometer
The most convenient way to measure your baby’s temperature is to use
the soother thermometer. This is also the most comfortable method for
the baby.
Do not use the soother thermometer for 30 minutes after the baby
has had hot or cold drinks, as this causes an inaccurate measurement.
Never use the soother thermometer as a regular soother.
ENGLISH 9
1 Check if the measurement unit of the soother thermometer is
rmly attached to the soother (i.e. turned completely to the closed
lock position).
If the measurement unit is not rmly attached to the soother, the
measurement may be inaccurate and the measurement unit
may become a suffocation hazard.
2 Place the soother in the baby’s mouth for approx. 3 minutes to let
the thermometer warm up.
If you do not do this, the measured temperature may be inaccurate.
3 Press the on/off button I to switch on the thermometer.
Note: You can either press the on/off button while the soother is still in your
baby’s mouth, or you can remove the soother, press the on/off button and
place the soother back into your baby’s mouth.
4 Leave the soother in the baby’s mouth until the thermometer
beeps.
See section ‘Audible signals’ at the end of this chapter for the meaning of
the beeps.
, The display now shows the measured temperature and the °C
indication lights up continuously.
Note: If for some reason the temperature cannot be measured, the display
shows ‘Lo’ or ‘Hi’. This means that the temperature is outside the temperature
range. Switch off the thermometer, check if it is correctly positioned and
switch it on again to restart the measurement.
5 Remove the soother thermometer from the baby’s mouth.
Do not leave the child alone with the soother thermometer.
6 Press the on/off button I to switch off the thermometer.
Note: Switch off thermometer after use to save battery power. If you do not
switch off the thermometer, it switches off automatically: - after 1 minute if
the temperature measured is <32°C; - or after 10 minutes if the
temperature measured is >32°C.
ENGLISH10
Digital exible-tip thermometer
Do not insert the exible-tip thermometer into the ear or nose.
The soother thermometer is just as accurate as the digital exible-tip
thermometer and is more convenient to use. However, because rectal
measurement is inherently more accurate than oral measurement, the
digital exible-tip thermometer gives you an opportunity to reassure
yourself.
For a rectal measurement of a baby’s temperature, proceed as follows:
1 Remove the protection cap from the digital exible-tip
thermometer.
Make sure that the metal probe of the exible tip is still rmly attached to
the thermometer.
Tip: If available, use special plastic hygienic covers to cover the tip of the
thermometer (these are available from most chemists).
2 Lubricate the tip of the thermometer (or hygienic cover) with a
water-soluble jelly.
Water-soluble jelly is available from most chemists.
Note: Do not use petroleum jelly.
3 Press the on/off button I to switch on the thermometer.
4 Lie the baby on its stomach or its side.
5 With one hand, separate the baby’s buttocks. With the other hand,
gently slide the tip of the thermometer no more than 12mm (1/2
inch) into the rectum. If you detect any resistance, stop immediately.
Hold the baby rmly so that it cannot turn while the thermometer is
inserted.
Never push the exible tip too far into the anus.
6 Keep the thermometer in place until it beeps.
See section ‘Audible signals’ at the end of this chapter for the meaning of
the beeps.
ENGLISH 11
Note: If for some reason the temperature cannot be measured, the display
shows ‘Lo’ or ‘Hi’. This means that the temperature is outside the temperature
range. Switch off the thermometer, check if it is correctly positioned and
switch it on again to restart the measurement.
7 Remove the thermometer and read the display.
8 Press the on/off button I to switch off the thermometer.
Note: Switch off thermometer after use to save battery power. If you do not
switch off the thermometer, it switches off automatically: - after 1 minute if
the temperature measured is <32°C; - or after 10 minutes if the
temperature measured is >32°C.
Measuring the temperature of older children
For older children and adults, the digital exible-tip thermometer can also
be used to measure temperature orally (in the mouth) or axially (in the
armpit).
Do not use the exible-tip thermometer for oral temperature
measurements on babies.
If the thermometer has been used rectally or in the armpit without
hygienic covers, do not use it for oral measurement anymore for
hygienic reasons, not even after cleaning.
Audible signals
Signal Meaning
10 beeps in 10 seconds Measured temperature is normal
(below 37.8°C)
3 sets of short beeps in 10
seconds
Possible fever (measured temperature
above 37.8°C)
ENGLISH12
Features
Last temperature recall
Both the soother thermometer and the digital exible-tip thermometer
have a memory function. When the soother thermometer and the digital
exible-tip thermometer are switched on, the display automatically shows
the last measured temperature for approx. 2 seconds. The display then
shows the normal body temperature of 37°C.
Battery-low indication
Both the soother thermometer and the digital, exible-tip thermometer
have a long-life battery which should last for about 2 to 3 years. If the
display shows a battery symbol, the battery is low. Replace the battery of
the exible-tip thermometer (see chapter ‘Replacing the battery’).
Note: The battery of the soother thermometer cannot be replaced. If the
battery is empty, discard the soother thermometer.
Automatic shut-off
Both the soother thermometer and the digital exible-tip thermometer
switch off automatically: - after 1 min if the temperature measured is
<32°C; - or after 10 min if the temperature measured is >32°C.
Error function
Both the soother thermometer and the digital exible-tip thermometer
have an error function. In case of malfunction, the display shows an ‘Err’.
Proceed as follows if this happens:
1 Press the on/off button I to switch off the thermometer.
2 Press the on/off button I to switch on the thermometer again.
Cleaning
Do not use abrasive cleaning agents, anti-bacterial cleaning agents or
chemical solvents. Excessive concentration of cleaning agents may
eventually cause plastic components to crack. Do not use cracked
parts.
ENGLISH 13
Clean the regular soother, the soother thermometer and the exible-tip
thermometer after each use to ensure optimal hygiene.
Be careful not to damage the parts when you clean them.
Cleaning the soother thermometer
Before rst use, wash and rinse the soother thoroughly.
Clean the soother before each use.
Before cleaning, always remove the measurement unit from the teat
and shield.
1 Turn the measurement unit 90° anticlockwise with respect to the
shield.
2 Pull the measurement unit straight out of the teat and shield.
Note: Be careful not to bend the tip of the measurement probe.
3 Clean the thermometer measurement unit with a soft damp cloth.
Do not immerse the measurement unit in water.
Do not sterilise or boil the measurement unit.
Do not clean the measurement unit in the dishwasher, in
the microwave or in a microwave steriliser.
4 Sterilise or boil the soother and protection cap (not the
measurement unit!).
The soother and cover are suitable for all forms of sterilisation.
Sterilise using a Philips AVENT Steam Steriliser or boil in water for 5
minutes.
If you use a sterilising solution, follow the instructions on the package. Do
not leave the soother in the sterilising solution for longer than
recommended, as this may weaken the teat.
Wash your hands thoroughly and ensure surfaces are clean before
contact with sterilised components.
5 After sterilisation, let the soother cool down for 5 minutes and
squeeze out any trapped water from the teat. This is to ensure
hygiene.
ENGLISH14
To reassemble the soother thermometer:
1 Align the blocks of the measurement unit with the matching slots
in the back of the shield.
2 Insert the measurement unit into the shield. Make sure that the tip
of the probe goes into the pocket inside the teat. (Fig. 3)
3 Turn the measurement unit 90° clockwise to lock it into position.
Cleaning the exible-tip thermometer
Do not sterilise or boil the thermometer.
Do not clean the exible-tip thermometer in the dishwasher, in the
microwave or in a microwave steriliser.
1 Clean the exible-tip thermometer with a soft damp cloth.
Cleaning the regular soother
Before rst use, wash and rinse the soother thoroughly.
Clean the soother before each use.
1 Sterilise or boil the soother.
The soother and cover are suitable for all forms of sterilisation.
Sterilise using a Philips AVENT Steam Steriliser or boil in water for 5
minutes.
If you use a sterilising solution, follow the instructions on the package. Do
not leave the soother in the sterilising solution for longer than
recommended, as this may weaken the teat.
Wash your hands thoroughly and ensure surfaces are clean before
contact with sterilised components.
2 After sterilisation, let the soother cool down for 5 minutes
and squeeze out any trapped water from the teat. This is to
ensure hygiene.
Cleaning the storage box
Do not sterilise the storage box.
ENGLISH 15
1 Wipe the storage box with a damp cloth.
Storage
You can use the storage box to store the soother, the soother
thermometer and the exible-tip thermometer or to take them with you
when you travel.
1 Put the protection caps on the soother, the soother thermometer
and the exible-tip thermometer after use to keep them clean.
2 Put the soother, the soother thermometer and the exible-tip
thermometer in the storage box.
3 Put the storage box in a safe, dry place away from direct sunlight
and heat sources.
Replacing the battery
Swallowing a button battery is extremely dangerous.
Batteries may explode if exposed to high temperatures or re.
Never attempt to recharge the battery.
If the display shows a battery symbol, the battery is low.
Replace the battery of the exible-tip thermometer as described below.
Note: The battery of the soother thermometer cannot be replaced. If the
battery is empty, discard the soother thermometer.
1 Remove the battery compartment cover (Fig. 4).
2 Use an insulated probe to remove the battery (e.g. a toothpick).
3 Insert a new battery (LR41) with the + pole facing upwards (Fig. 5).
4 Reattach the battery compartment cover (Fig. 6).
5 Dispose of the empty battery in the proper way (see chapter
‘Environment).
ENGLISH16
Environment
- Non-rechargeable batteries contain substances that may pollute the
environment. Do not throw away non-rechargeable batteries with the
normal household waste, but dispose of them at an ofcial collection
point for batteries. Always remove the non-rechargeable batteries
before you discard and hand in the thermometers at an ofcial
collection point (Fig. 7).
- Do not throw away the thermometers with the normal household
waste at the end of their life, but hand them in at an ofcial collection
point for recycling. By doing this, you help to preserve the
environment (Fig. 8).
Guarantee & service
If you need service or information or if you have a problem, please visit
the Philips AVENT website at www.philips.com/AVENT or contact the
Philips Consumer Care Centre in your country (you nd its phone
number in the worldwide guarantee leaet). If there is no Consumer
Care Centre in your country, go to your local Philips dealer.
ENGLISH 17
Technical specications
Digital exible-tip
thermometer
Soother
thermometer
AVENT
soother
Battery 1.55VDC (LR41) Battery not
replaceable
-
Battery life > 100 operating
hours
> 100 operating
hours
-
Measurement
range
32°C to 42.9°C 32°C to 42.9°C -
Accuracy ± 0.1°C for 35°C
to 42°C range
± 0.1°C for 35°C
to 42°C range
-
Teat size - Suitable for
newborn babies
Suitable for
newborn
babies
Compliance Conforms to
MDD93/42/EEC
Conforms to
MDD93/42/EEC
Conforms
to EN1400
ENGLISH18
19
簡介
恭喜您購買本產品並歡迎加入飛利浦 AVENT!請於 www.philips.
com/welcome 註冊您的產品,以善用飛利浦 AVENT 提供的支
援。
飛利浦 AVENT 數位體溫計組合可讓您準確輕鬆地測量寶寶的口
溫、腋溫和肛溫。其中的普通安撫奶嘴與安撫奶嘴型體溫計適合 0
至 12 個月大的嬰幼兒使用。數位彈性尖頭體溫計則適合所有年齡
的孩童與成人使用。
此特殊組合包含安撫奶嘴型體溫計與彈性數位尖頭體溫計,您可
選擇適合寶寶的體溫測量方式。
收納盒中含有三個配件:
- 安撫奶嘴型體溫計可確實測量寶寶的體溫,不但使用方便,對
寶寶也很舒適。
- Freeflow 安撫奶嘴可讓寶寶習慣體溫計的形狀。
- 若想更安心,您可使用數位彈性尖頭體溫計,測量寶寶的腋溫
或肛溫。
使用這些配件時,請務必遵循安全守則,避免讓寶寶暴露於任何
危險中。
請使用安撫奶嘴型體溫計取得溫度標示,而使用彈性尖頭體溫計
來判定實際體溫。若有疑問,請諮詢您的醫師。
重要事項
一般
- 體溫計上所標示的各種符號意義如下:
1 此符號表示使用本產品前需詳閱使用說明。請保存使用說明以
供日後參考。 (圖 1)
2 此符號為識別 BF 型零件符合 IEC60601-1 標準。 (圖 2)
維護孩童的安全警示!
- 切勿在安撫奶嘴上綁繫絲帶或繩索,以免纏繞勒住孩童。
- 每次使用時安撫奶嘴時,特別是孩童長牙時,請詳加檢查。請
將安撫奶嘴往各個方向輕拉,若有損壞或變質的現象,請立即
丟棄。
- 請勿將安撫奶嘴直接曝曬在陽光下、接近高溫熱源或置於消毒
劑 (「殺菌溶液」) 中超過建議時間,以避免奶嘴脆弱變質。
- 請勿讓孩童把玩奶嘴的可拆式保護 (蓋),以免發生窒息危險。
繁體中文
- 第一次使用前,請浸泡於滾水中 5 分鐘,冷卻後將奶嘴裡的所
有水分擠出,確保衛生。
- 使用前務必清潔產品。
- 切勿將奶嘴浸泡在糖水或藥物中,這可能會讓孩童罹患蛀牙。
- 基於孩童的安全與衛生考量,安撫奶嘴使用 4 週後,便需更
換。
- 萬一安撫奶嘴卡在口腔中,切勿驚慌。此狀況已在設計的考量
範圍內,孩童無法吞食奶嘴。請從口腔中小心移除安撫奶嘴,
動作盡量輕柔。
- 此產品必須在成人監督下使用。請保存在乾燥加蓋的容器中。
安撫奶嘴和保護蓋適用於所有一般常用的殺菌方式。觸碰已消
毒的零件之前,請徹底洗手,確保雙手表面是乾淨的。
- 安撫奶嘴可用溫水清洗。
- 請勿使用具有磨蝕性的清潔劑或殺菌清潔劑清潔安撫奶嘴。濃
度過高的清潔劑最後可能會造成塑膠零件碎裂。若發生這種情
形,請立即更換奶嘴。
- 請勿消毒展示盒。
- 如需更多清潔建議,請參閱「清潔」單元。
警示
- 請勿將安撫奶嘴型體溫計的測量組件浸泡於水中或任何液體
中,切勿對測量組件進行殺菌或煮沸消毒。
- 當您使用安撫奶嘴型體溫計或彈性尖頭體溫計為孩童測量體溫
時,切勿離開。
- 本體溫計不適合供下列人士 (包括小孩) 使用:身體官能或心智
能力退化者,或是經驗與使用知識缺乏者。他們需要有負責其
安全的人員在旁監督,或教導體溫計的使用方法,方可使用。
- 請看管孩童,避免他們將體溫計當成玩具。
- 請勿單獨使用安撫奶嘴型體溫計測量組件,避免受傷。
- 請勿將安撫奶嘴型體溫計當作普通安撫奶嘴使用。
- 電池槽蓋若被移除,請務必妥善裝回。脫落的電池槽蓋可能會
哽塞孩童的喉嚨。
警告
- 請勿將安撫奶嘴置於消毒劑中 (「消毒溶液」) 超過建議時間,
以避免奶嘴頭脆弱變質。
- 請勿讓體溫計掉落地面或受到重擊。
繁體中文20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Philips Thermometer SCH540 ユーザーマニュアル

カテゴリー
デジタル体温計
タイプ
ユーザーマニュアル
このマニュアルも適しています

他の言語で