3631101000

Blueair 3631101000 ユーザーマニュアル

  • こんにちは!Blueair 3610空気清浄機の取扱説明書を読み込みました。この空気清浄機の特徴であるHEPA Silent™フィルターや、自動運転モード、フィルター交換インジケーターなどについて、ご質問にお答えします。どうぞお気軽にご質問ください!
  • フィルター交換時期はどうやって分かりますか?
    プレフィルターのお手入れ方法は?
    推奨使用面積はどのくらいですか?
    運転モードはどのようなものがありますか?
󻕻󻭸󻗳󺽔󻗫
󰾫󵈾󳅜󱍂
Blue 3610
User Manual
取扱説明書
3
EN
Blue 3610 4
Safety instructions 6
Get started 8
Filters 11
Care and maintenance 15
Disposal and recycling 17
Help and support 17
Warranty information 17
Specifications 18
Contents
Please read this user manual carefully and keep it for future reference.
The latest version of this user manual can be found on www.blueair.com
Note: There may be local variations of these models.
Product name: Model number:
Blue 3610 3631101000
4
Blue 3610
The air purifier has a pre-filter and a HEPASilentTM main filter to purify air. It has control
functions and a built-in sensor.
The air purifier is mainly composed of a motor, a fan and filters. The air purifier removes
contaminants from the air in a room to improve indoor air quality.
You can change the air purifier settings at any time, using the control panel on the air purifier.
Recommendations for best performance
Use the air purifier in a room that does not exceed the room size recommendation.
Place the air purifier in a location where air can circulate freely in, out and around the air
purifier.
Do not place the air purifier closer than 10cm to another object.
During operation, keep doors and windows in the room with the air purifier closed.
Only use genuine Blueair filters.
Change the main filter when the filter replacement indicator appears on the control
panel.
Follow the maintenance instructions in this user manual.
5
A Air quality indicator F Air quality sensor
B Touch button G Release button
C Air outlet H Pre-filter
D Fan and motor I Power cable (not in picture)
E Main filter J User Manual (not in picture)
B
C
D
A
E
F
H
G
6
Safety instructions
Blue 3610 air purifier is an electrical appliance for indoor use only,
take the necessary precautions to reduce the risk of fire, electric
shock or injury.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Supervise children to ensure that they do not play with the
appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Always disconnect the appliance from the power supply before
maintenance.
Do not attempt to open or service the appliance yourself. Service
must be done by the manufacturer, service agent or similarly
qualified personnel using only original Blueair spare parts.
Ensure that the power cable and the power plug are not at risk of
getting damaged. To avoid hazard, a damaged power cable must
always be replaced by the manufacturer, service agent or similarly
qualified person.
If the appliance is damaged or malfunctions, turn it o, disconnect
it from the power supply and contact Blueair.
The power plug must be firmly inserted in the power socket.
When disconnecting the unit from the power supply, do not pull on
the power cord, pull on the power plug.
Use the power cable provided with your Blueair air purifier to plug
7
directly and firmly into an appropriate, electrical outlet.
Do not use an extension cord or a power strip. Refer to the rating
label on your appliance.
Do not alter the power plug in any way. If the plug does not fit into
the outlet, contact qualified personnel to install the proper outlet.
Do not use the included power cord for anything else but the
appliance.
Do not allow objects to enter or block the air inlets and air outlets
as this can cause electric shock or damage the appliance.
Do not place any objects on top of or directly against the
appliance.
Do not sit on, stand, climb onto or hang from the appliance.
Keep the appliance, including the power cable, at a safe distance
from heated surfaces and open fire.
Keep the appliance and power plug away from water and other
liquids.
Keep the appliance and power plug away from chemicals such as
pesticides and deodorants.
Place the appliance on the floor. The appliance must be placed on
a stable surface.
Do not use the appliance outdoors or in wet environments such as
bathrooms, laundry rooms or pool areas.
8
Get started
Step 1
Plug the power cable
into a wall outlet.
Step 2
Press the button to
turn the air purifier
on and adjust the fan
speed mode.
The autostart feature automatically restarts the air purifier at the last set speed if it has
been unplugged, used with a power switch timer, or if a power failure occurs.
In auto mode the air purifier automatically controls the airflow based on air quality
information from the sensor.
Autostart
Auto mode
Available settings: Auto, Night, Everyday, Boost and O.
The indicator lights on the touch button indicate the selected fan speed. The lights
automatically dim down completely 5 seconds after pressing the touch button, indicating a
deactivated fan speed control mode. Press the touch button once to reactivate on/o and
fan speed control. The indicator lights light up and you can adjust the fan speed mode again.
On/O and fan speed controls
9
Press once to turn the unit On and to set it to Auto mode.
On/Auto mode
Press twice to set to Night mode (low fan speed).
All lights on the unit dim down after 5 seconds.
Night mode
Press three times to set to Everyday mode (medium fan speed).
Everyday mode
Press four times to set to Boost mode (high fan speed).
Press five times to turn the unit O.
Boost mode
O
10
Air quality information
The air quality levels for particulate matter (PM) are indicated using a color scale on the air
quality indicator. The air quality indicator is completely dimmed in Night mode.
Air quality level (PM 2.5)
PM2.5, Particulate matter, particles with diameter of size 2.5 micrometers or less.
Polluted
Moderate
Good
11
Button control functions
Filters
The air purifier is delivered with a fabric pre-filter and a main filter. The filters purify the
air from both particles and gases. For best performance, clean the pre-filter regularly and
change the main filter when the air purifier indicates filter change.
To find the right main filter for your air purifier, use the Blueair app or visit www.blueair.com.
The model number of your air purifier can be found on the rating label on the air purifier.
Change filter
When the indicator
light turns red (after 6
months of operation)
you should change
the main filter.
Filter replacement
indicator
Press the button
down for 7 seconds
to reset the filter
replacement
indicator.
Blueair filter subscription program
Use the Blueair app or visit www.blueair.com to sign up for the Blueair filter subscription
program. (Not available in all markets)
Important! Always turn o and disconnect the appliance from the power supply before
changing filters, cleaning or carrying out maintenance procedures.
Note: Using a fabric pre-filter is optional.
12
Clean and change the pre-filter
For best performance, clean the pre-filter regularly. Vacuum the exterior of the fabric pre-
filter with a soft brush attachment to remove dust. If the pre-filter requires a deeper clean,
wash it in the washing machine, according to instructions on the pre-filter´s label.
Important! Press the Velcro strips together on the pre-filter before machine wash.
Step 5
Wash the pre-filter in
the washing machine,
according to instructions
on the pre-filter´s label.
Step 1
Turn the unit o and
unplug it.
Step 3
Remove the top part from
the unit.
Step 2
Gently press the buttons
on both sides of the unit
simultaneously.
Step 6
Place the pre-filter back
onto the unit.
Adjust the pre-filter and
the panel to hide the
power cord in the back.
Step 7
Place the top back onto
the unit and press until
you hear a click.
Step 8
Plug in the unit.
Step 4
Open the pre-filter panel
and remove the pre-filter.
13
Change the main filter
When changing the filter, vacuum any dust that may have accumulated inside the unit.
Important! Use only genuine Blueair filters suitable for the model to ensure proper function
and performance of the air purifier, and to qualify for full warranty coverage.
Step 5
Remove the old main filter
from the unit.
Unfold the new main filter
and insert into the unit.
Step 1
When the indicator light
glows red, its time to
change the main filter.
Step 3
Gently press the buttons
on both sides of the unit
simultaneously.
Step 2
Turn the unit o and
unplug it.
Step 4
Remove the top part
from the unit.
Step 6
Place the top part onto
the bottom part of the
unit. Firmly press the top
part onto the metal filter
frame until you hear a
click.
14
Step 7
Plug in the unit.
Step 8
Press the touch button
for a duration of 7
seconds to reset the filter
replacement timer.
This lets the air purifier
know that you have
changed the filter.
The indicator light flashes
for 4 seconds, and then
changes from red to white.
15
Care and maintenance
General
Disconnect the air purifier from the power supply before maintenance.
Do not allow foreign objects to enter the air inlets or air outlets. This may cause electric
shock or damage the air purifier.
Never clean with gasoline, chemical solvents or corrosive materials as these agents may
damage the air purifier.
Make sure the air purifier is completely dry before connecting it to power.
Do not wash the main filter. The main filter is not washable or reusable.
Cleaning
Wash the pre-filter according to the instructions on the pre-filter´s label or vacuum the
pre-filter with a soft brush attachment.
Wipe the exterior of the air purifier with a soft, clean, damp cloth.
Clean and check the power cable and power plug for wear or damages.
Clean the sensor when changing the main filter.
16
Clean the air quality sensor
The inlet for the air quality sensor is located at the back of the air purifier.
Important! Do not use fingers or any unrecommended objects to clean inside the sensor inlet.
Step 3
Remove the top part from
the unit.
Step 4
Press the button on
the inside of the unit to
open the lid covering
the sensor and remove
the lid.
Step 5
Using circular motions,
gently clean the sensor
with a cotton swab, and
attach the sensor lid.
Step 2
Gently press the buttons
on both sides of the unit
simultaneously.
Step 6
Place the top part onto
the bottom part of the
unit. Firmly press the top
part onto the metal filter
frame until you hear a
click.
Step 7
Plug in the unit.
Step 1
Turn the unit o and
unplug it.
17
Warranty information
The Blueair Limited Warranty applies only if the air purifier is installed, used and maintained
according to the instructions in this manual.
For warranty conditions, please visit www.blueair.com/warranty
Warranty and returns
If you purchased the air purifier at one of our authorized retailers, please contact the same
store to request assistance.
Help and support
If you have questions about your product, please visit www.blueair.com or contact your local
Blueair retailer.
To contact Blueair for personalized support, please visit www.blueair.com/customer-support
This air purifier should be disposed or recycled as electrical waste and the filter may be
recycled as plastic. If you have questions regarding the disposal and recycling of this air
purifier, please contact your local recycling facility for availability or Blueair dealer and ask for
the correct method of recycling.
Disposal and recycling
18
Specifications
Blue 3610
Input Power, Frequency 100-240VAC 50/60Hz
Power consumption/
Rated input power 4-38W
Sound level (min/max)1 23-56 dB(A)
Recommended room size2550 ft2 (51 m2)
CADR Smoke2353 cfm (600 m3/h)
CADR Dust2347 cfm (590 m3/h)
CADR Pollen2380 cfm (650 m3/h)
1 Sound pressure according to GB/T18801 and GB4214.1
2According to ANSI/AHAM AC-1-2019. Tested without pre-filter.
JP
 20
 21
安全上のご注意 22
初めて使うとき 27
フィルターについて 30
お手入れをする 36
本体を廃棄するときは 38
アフターサービスについて 38
保証について 38
主な仕様 39
目次
ご使用の前に、本書を必ずよくお読みください。
本書は紛失しないよう、大切に保管してください。
本書の最新版データは、www.blueair.jp に掲載されています。
注意 :国により取扱モデルが異なります。
商品名 :品番 :
3610 3631101000
Blue3610は
各部名称
19
20
Blue 3610 とは
空気清浄機を正しく使用すると、室内空気から有害物質を除去して、きれいな空気の中
で生活することができます。
空気清浄性能を最大限に発揮するためには
• 推奨フロア面積を目安とした広さの空間でご使用ください。
• 本体周辺に空気が循環できるスペースを空けてご使用ください。
• 本体の周辺 10 cm 以内には物を置かないでください。
• 部屋の窓やドアを閉めた状態でご使用ください。
Blueair の純正フィルターをご使用ください。
• 操作パネルにフィルター交換お知らせランプが点灯したら、メインフィルターを交
換してください。
• 本書の内容に従って、定期的にお手入れをしてください。
/