Edge-Core EPS122 ユーザーマニュアル

タイプ
ユーザーマニュアル

このマニュアルも適しています

1
Quick Start Guide
1. Reset button
2. System — Green (OK), Amber (fault detected)
PSU1/2 — Green (OK), Amber (fault)
FAN — Green (OK), Amber (fault)
LOC — Blinking Amber (switch locator)
PoE — Green (OK), Amber (near PoE budget)
3. RJ-45 Port LEDs: Green (link), Amber (link with PoE)
4. SFP+ Port LEDs: Green (10G), Amber (1G)
5. RJ-45 Management Port LEDs: Left (link), Right (activity)
3
2
55
1
4
E072023-CS-R01
150200002546A
Ethernet Switch
AS4625-54T | AS4625-54P
1.
AS4625-54T/AS4625-54P (includes 2 PSUs)
2. Rack Mounting Kit—2 brackets and 8 screws
3. USB Micro-B to USB-A cable
4. Four adhesive rubber feet
5. Console cable—RJ-45 to DE-9
6. (Optional) AC power cord
7. Documentation—Quick Start Guide (this document) and Safety
and Regulatory Information
Package Contents
Overview
FRU Replacement
1
Status LEDs
1. 40 x 1G RJ-45 PoE ports (30 W per port)
2. 8 x 1G RJ-45 PoE ports (90 W per port)
3. 6 x 1G/10G SFP+ ports
4. 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
5. 2 x AC PSUs
6. 2+1 fixed redundant fans
7. Grounding screw
1. 48 x 1G RJ-45 ports
2. 6 x 1G/10G SFP+ ports
3. 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
4. 2 x AC PSUs
5. 2+1 fixed redundant fans
6. Grounding screw
11 2
2
4
33 4
45
6556
7
AS4625-54T AS4625-54P
www.edge-core.com

2 5 6 7
PSU Replacement
1. Remove the power cord.
2. Press the release latch and
remove the PSU.
3. Install replacement PSU.
PSU Replacement
1. Remove the power cord.
2. Press the release latch and
remove the PSU.
3. Install replacement PSU.
AS4625-54PAS4625-54T
43
Quick Start Guide
2
Mount the Device in a Rack
1. Use the included flathead M4x8 screws to attach the brackets.
2. Use the screws and cage/clip nuts supplied with the rack to
secure the device in the rack.
Ground the Device
Verify Rack Ground
Ensure the rack is properly grounded and in compliance with
international and local standards. Verify that there is a good electrical
connection to the grounding point on the rack (no paint or isolating
surface treatment).
Attach Grounding Wire
Attach a grounding wire (#14 AWG/1.5 mm2, green with yellow stripe)
to the grounding point on the device’s rear panel or side panel. Then
connect the other end of the wire to rack ground.
Connect Power
Install one or two AC PSUs in the device, if they are not already installed
in the factory. Then connect an external AC power source to the PSUs.
Make Network Connections
RJ-45 Ports
Connect Category 5, 5e or better twisted-pair cable.
SFP+ Ports
Install transceivers and then connect fiber optic cabling to the transceiver
ports. Alternatively, connect AEC/AOC/DAC cables directly to the SFP+
slots.
The following transceivers are supported in the SFP+ ports:
10GBASE-SR, LR, CR, T
1000BASE-SX, LX, T
Warning:
For a safe and reliable installation, use only
the accessories and screws provided with the device. Use
of other accessories and screws could result in damage to
the unit. Any damages incurred by using unapproved
accessories are not covered by the warranty.
Avertissement:
Pour une installation sûre et fiable,
utilisez uniquement les accessoires et les vis fournies avec
l’appareil. L’utilisation d’autres accessoires et vis pourrait
endommager l’appareil. Les dommages causés par
l’utilisation d’accessoires non approuvés ne sont pas
couverts par la garantie.
Caution:
The device must be installed in a restricted-access
location.
Attention:
L’appareil doit être installé dans un emplacement
à accès restreint.
Note:
The device has the Open Network Install Environment
(ONIE) software installer preloaded, but no software image.
Information about compatible software can be found at
www.edge-core.com.
Note:
The drawings in this document are for illustration only
and may not match your particular model.
Note:
The device can also be installed on a desktop or shelf
using the included adhesive rubber feet.
1
Caution:
The earth connection must not be removed unless
all supply connections have been disconnected.
Attention:
Le raccordement à la terre ne doit pas être retiré
sauf si toutes les connexions d’alimentation ont é
débranchées.
2
3
4
Installation
Quick Start Guide
3
Make Management Connections
Micro-USB Port
Use the included Micro-USB cable to connect to an external storage
device.
Mgmt RJ-45 Port
Connect Category 5, 5e or better twisted-pair cable.
RJ-45 Console Port
Use the included RJ-45-to-DE-9 null-modem console cable to connect to
a PC running terminal emulator software. Use a USB-to-male DE-9
adapter cable (not included) for connections to PCs that do not have a
DE-9 serial port.
Configure the serial connection: 115200 bps, 8 characters, no parity,
one stop bit, 8 data bits, and no flow control.
Console cable pinouts and wiring:
Device’s RJ-45 Console Null Modem PC’s 9-Pin DTE Port
6 RXD (receive data) <---------------- 3 TXD (transmit data)
3 TXD (transmit data) ----------------> 2 RXD (receive data)
4,5 SGND (signal ground) ------------------ 5 SGND (signal ground)
5Hardware Specifications
Size (WxDxH) 440 x 350.35 x 44 mm (17.32 x 13.79 x 1.73 in.)
Weight AS4625-54T: 5.8 kg (12.77 lb), includes two PSUs
AS4625-54P: 6.6 kg (14.55 lb), includes two PSUs
Temperature Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power
Consumption
(at 25° C)
AS4625-54T: 150 W max.
AS4625-54P:
Low-line (90–136 VAC): 2000 Watts max.
High-line (180–264 VAC): 2400 Watts max.
System Input
Rating (per
PSU)
AS4625-54T:
100–120 VAC, 50/60 Hz, 4 A max.
200–240 VAC, 50/60 Hz, 2 A max.
AS4625-54P:
100–120 VAC, 50/60 Hz, 12 A max.
200–240 VAC, 50/60 Hz, 8.5 A max.
PoE Budget AS4625-54P:
Low-line: 850 W for 1 PSU, 1850 W for 2 PSUs
High-line: 1050 W for 1 PSU, 1920 W for 2 PSUs
Regulatory Compliances
Emissions EN 55032
EN 61000-3-2
EN 61000-3-3
FCC Title 47, Part 15, Subpart B, Class A
VCCI-CISPR 32
BSMI Class A
IECS-003 Issue 7
AS/NZS CISPR 32
KS C 9832
Immunity EN 55024/EN 55035
KS C 9835
IEC 61000-4-2/3/4/5/6/8/11
Safety UL (CSA 22.2 No 62368-1 & UL 62368-1)
CB (IEC/EN 62368-1, 2nd & 3rd Ed)
BSMI CNS 15598-1
Taiwan RoHS CNS 15663
Warranty Information and Technical Support
Registering your product enables you to receive a more efficient warranty service. Be sure to register at www.edge-core.com.
4
1. 重設按鈕
2. 系統綠燈 (良好)、黃燈 (偵測到故障)
PSU1/2綠燈 (良好)、黃燈 (故障)
風扇綠燈 (良好)、黃燈 (故障)
LOC閃黃燈 (交換器定位器)
PoE綠燈 (良好)、黃燈 (接 PoE 預算)
3. RJ-45 LED:綠燈 (連接)、黃燈 (連接 PoE
4. SFP+ LED:綠燈 (10G)、黃燈 (1G)
5. RJ-45 管理連接埠 LED:左 (連結 )、右 (活動 )
3
2
55
1
4
乙太網路交換器
AS4625-54T | AS4625-54P
1.
AS4625-54T/AS4625-54P ( 包括 2 PSU)
2. 機櫃安裝套件 —2 個托架和 8 個螺絲
3. USB Micro-B USB-A 纜線
4. 四個黏性橡膠腳墊
5. 主控台纜線 —RJ-45 DE-9
6. (選配) AC 電源線
7. 文件-快速入門指南 (本文件)及安全及法規資訊
包裝內容物
簡介
更換 FRU
1
LED 狀態
1.
40 x 1G RJ-45 PoE 連接埠 ( 每埠 30 W)
2. 8 x 1G RJ-45 PoE 連接埠 ( 每埠 90 W)
3. 6 x 1G/10G SFP+ 連接埠
4. 1000BASE-T RJ-45RJ-45 控制埠、微型 USB 儲存埠
5. 2 x AC PSU
6. 2+1 固定備援風扇
7. 接地螺絲
1.
48 x 1G RJ-45 連接埠
2. 6 x 1G/10G SFP+ 連接埠
3. 1000BASE-T RJ-45RJ-45 控制埠、微型 USB 儲存埠
4. 2 x AC PSU
5. 2+1 固定備援風扇
6. 接地螺絲
11 2
2
4
33 4
45
6556
7
AS4625-54T AS4625-54P
www.edge-core.com
2 5 6 7
更換 PSU
1.
取下電源線。
2. 按住釋放桿並取出 PSU
3. 安裝更換的 PSU
更換 PSU
1.
取下電源線。
2. 按住釋放桿並取出 PSU
3. 安裝更換的 PSU
AS4625-54PAS4625-54T
43
快速入門指南
5
將裝置裝到機櫃中
1.
使用內附的平頭 M4x8 螺絲安裝托架。
2. 使用機櫃隨附提供的螺絲與支架/彈簧夾螺帽將裝置固定於
機櫃上。
將裝置接地
確認機架接地
請確保機櫃正確接地,並符合國際與當地標準。確認與機櫃接地點間
有良好的電氣連接性 (無油漆或絕緣表面處理)
安裝接地線
將接地線 (#14 AWG/1.5 mm2,綠色及黃色條紋)安裝在裝置後面
板或側面板接地點上。接下來,將接地線另一端連接至機櫃接地。
連接電源
若尚未在原廠中安裝,請在裝置中安裝一或兩部 AC PSU。然後將外
AC 電源連接至 PSU
進行網路連線
RJ-45
連接 Category 55e 或更好的雙絞線。
SFP+
安裝收發器,然後將光纖電纜連接至收發器連接埠。或可將 AEC/
AOC/DAC 電纜直接連接至 SFP+ 插槽。
SFP+ 連接埠支援下列收發器:
10GBASE-SRLRCRT
1000BASE-SXLXT
警告:
為確保安全且可靠的安裝,請使用裝置隨附的配件
與螺絲。使用其他來源的配件與螺絲可能導致配件損壞。
使用未經許可配件所造成之損壞,不在保固範圍內。
注意:
裝置必須安裝在限制出入地點。
附註:
本裝置預先安裝了 「開放網路安裝環境 (Open
Network Install EnvironmentONIE」軟體安裝程式,
但沒有軟體圖示。關於相容軟體的資訊,可上此網站:
www.edge-core.com
附註:
本文件中的示意圖僅供參考,可能與特定型號有
所差異。
附註:
亦可利用內附之黏性橡膠腳墊,將此裝置安裝在
桌上或層架上。
1
注意:
在切斷所有電源接線前,不得移除接地連接。
2
3
4
安裝
快速入門指南
6
進行管理連接
微型 USB 連接埠
利用隨附的微型 USB 纜線連接外部儲存裝置。
Mgmt RJ-45 連接埠
連接 Category 55e 或更好的雙絞線。
RJ-45 控制埠
利用隨附的 RJ-45- -DE-9 虛擬數據機電纜線來連接至執行虛擬終
端機軟體的電腦。使用 USB- - DE-9 轉接纜線 (未隨附)來連
接至未配備 DE-9 序列埠的電腦。
設定序列連線:115200 bps8 個字元、無奇偶 (檢驗碼)1 個停
止位元、8 個資料位元,並且無流量控制。
主控台纜線接腳輸出及配線:
裝置的 RJ-45 主控台 虛擬數據機 電腦 9 接腳 DTE 連接埠
6 RXD (接收資料) <---------------- 3 TXD (傳送資料)
3 TXD (傳送資料) ----------------> 2 RXD (接收資料)
4,5 SGND (訊號接地) ------------------ 5 SGND (訊號接地)
5硬體規格
尺寸(寬 x
x 高)
440 x 350.35 x 44 毫米 (17.32 x 13.79 x 1.73 英吋 )
重量 AS4625-54T5.8 公斤 (12.77 磅),含兩部 PSU
AS4625-54P6.6 公斤 (14.55 磅),含兩部 PSU
溫度 操作:0° C 45° C 32° F 113° F
儲存:-40° C 70° C -40° F 158° F
濕度 操作:5% 95% (無冷凝)
功耗 (25° C
時)
AS4625-54T:最大 150 W
AS4625-54P
低壓線路 (90–136 VAC):最大 2000
高壓線路 (180–264 VAC):最大 2400
系統輸入額定
( PSU)
AS4625-54T
100–120 VAC50/60 Hz,最大 4 A
200–240 VAC50/60 Hz,最大 2 A
AS4625-54P
100–120 VAC50/60 Hz,最大 12 A
200–240 VAC50/60 Hz,最大 8.5 A
PoE 預算 AS4625-54P
低壓線路:850 W 適用於 1 PSU1850 W 適用
2 PSU
高壓線路1050 W 適用於 1 PSU1920 W 適用
2 PSU
符合法規
輻射 EN 55032
EN 61000-3-2
EN 61000-3-3
FCC Title 47, Part 15, Subpart B, Class A
VCCI-CISPR 32
BSMI Class A
IECS-003 Issue 7
AS/NZS CISPR 32
KS C 9832
電磁耐受性 EN 55024/EN 55035
KS C 9835
IEC 61000-4-2/3/4/5/6/8/11
安全性 UL (CSA 22.2 No 62368-1 & UL 62368-1)
CB (IEC/EN 62368-1, 2nd & 3rd Ed)
BSMI CNS 15598-1
臺灣 RoHS CNS 15663
保固資訊及技術支援
註冊產品可讓您收到更有效的保固服務資訊。請確定前往 www.edge-core.com 註冊。
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Edge-Core EPS122 ユーザーマニュアル

タイプ
ユーザーマニュアル
このマニュアルも適しています

他の言語で