JQG7505

FOTILE JQG7505 ユーザーマニュアル

  • FOTILE 30in Slant Vent Series レンジフードの取扱説明書の内容を読み終えました。このレンジフードの設置、使用方法、メンテナンスに関するご質問にお答えできます。安全な設置と使用のために、設置高さ、排気ダクトの仕様、その他の注意事項について説明されています。
  • レンジフードの推奨設置高さは?
    排気ダクトの推奨仕様は?
    設置時に注意すべきことは?
1. In order to secure the safe use of the range hood and maximize its ability to
ventilate cooking fumes, the installation height is suggested as follows: The
distance from the countertop of the gas stove to the top board of the range
hood shall not be less than 29 9/16"(750 mm) and shall not be more than
32 1/2"(825 mm). Where there are relevant laws stipulating the mounting
height of range hood in the state or region, the laws shall prevail. However,
the effect of cooking fumes ventilation might be affected.
2. When drilling into the wall or ceiling, be careful not to damage electrical
wiring, water pipes, gas lines, or other hidden utilities.
3. The wall should be strong enough to support the range hood. As for hollow
wall or hollow plate, the minimum thickness of the lumber should be 13/16"
(30 mm).
4. Shorten the length of ducting run to the hole on the outside wall and
decrease the turns to the minimum when designing the ducting run.
The requirements of the ducting run are:
1) the diameter of the ducting run is at least 6 inches;
2) iron sheet tube is the firstly suggested option for the ducting run and
then secondly the aluminum pipe;
3) the length of the ducting run is suggested no more than 8 feet and three
turns to ensure the best effect of oil suction.
Only operate the gas burners with cookware on them after installing the
range hood.
3) Installation Instructions for the Decorative Cover Without Upper Cabinet
110100051153F
󴇲󲵭󽶯
󱺞󳶤󳤚󰰗󸍧󶍄󷜹󳟘󳶤󳤚󷜹󹕴󳢐󼶳󴆨󴣣󳠭󲍨󷜹󱋦󼶳󷵵󱫈󽶵󹎗󽶳󽶲󽶴
󽶳󽶵󽶳󽶸󽶷󽶹󽶲󷕙󸵠󸽮󸎥󰹥󳅻󳶤󳤚󷜹󹕴󳢐󹟗󲤳󱍷󵮢󹟗󵌴󳠓
󱬊󼶳󰵕󱅧󷕙󸵠󵾨󱩿󳘒󰸴󴆨󴣣󳠭󱶡󰷯󱕡󵂠󱕪󲪭󶔢󲑘󶤛󵂿󱎂󳇡󳠽󳗱󴇐󲿓
󲧰󲽞󳗱󴇐󱆪󸼋󱊾󰷥󷤸󲍨󷜹󱪃
Note:
If a decoration board is installed at the lower edge of the cabinet,
a wood block at same height as decoration board near three
#10×2 13/16"(M5×70mm) bolts before installation of a range
hood, so as to avoid electric jogger's failure to open or close
properly caused by deformation of range hood shell during fas-
tening of the bolts. (See the installation diagram)
󳠓󱬊

󳶤󳤚󷜹󹕴󳢐


Installation Instruction:
1) Installation Instructions for FOTILE Range Hood with Upper Cabinet
2) Installation Instructions for the Decorative Plate with Upper Cabinet
7 11/16"(194.4mm)
or
5 11/16"(143.6mm)
6"(152.4mm)
or
4"(101.6mm)


󳖢󱸂󲎈󶎡

󽶺󽶺󽶺󽶵󽶳󽶷󽶲󽶵󽶸󽶸
󶐈󱪂󲬮󰻕󲎚󳟝
󶐈󱪂󳟝󱍸󵂿󷵛󽶺󽶺󽶺󽶵󽶳󽶷󽶲󽶵󽶸󽶸

󽶺󽶶󽶶󽶵󽶳󽶷󽶲󽶵󽶳󽶷
󱍷󳃎󱷼󲬮󰻕󲎚󳟝
󱍷󳃎󱷼󳟝󱍸󵂿󷵛󽶺󽶶󽶶󽶵󽶳󽶷󽶲󽶵󽶳󽶷
Please scan the QR code for more details
30in Slant Vent Series Installation Template
Center line
Rear wall
Upper-cabinet template
Stick this sheet beneath
bottom of the cabinet with
this side down.
Cut off the shadow area.
Please cut the 'Rear wall' side
according to the thickness of
the batten, if there is .
Rear wall
3/8"
8"
3 1/16"
12 1/16"
10 1/4"
1 3/8" 9 5/16"
15 9/16"
5 5/16" 3 5/8"
2 3/16"
/