Contents
1 Important 4
Safety 4
2 Yourairpurier 6
Product Overview 6
Controls overview 7
3 Getting started 8
Install lters 8
4 Using the appliance 10
Understand the air quality light 10
Switch on 10
Change the fan speed 11
5 Cleaning 13
Cleaning schedule 13
Clean the body of the appliance 13
Clean the air outlet cover 13
Clean the air quality sensor 14
Clean the pre-lter 15
6 Replacingtheairpuricationlter16
Understand the healthy air protect
lock 16
Replace the air purication lter 16
7 Resettingthelterlifetime
counter 17
8 Troubleshooting 18
9 Guarantee and service 20
Order parts or accessories 20
10 Notices 20
Electromagnetic elds (EMF) 20
Recycling 20
4
EN
1 Important
Safety
Read this user manual carefully before you
use the appliance, and save it for future
reference.
Danger
Do not let water or any other liquid
or ammable detergent enter the
appliance to avoid electric shock and/or
a re hazard.
Do not clean the appliance with water,
any other liquid, or a (ammable)
detergent to avoid electric shock and/
or a re hazard.
Do not spray any ammable materials
such as insecticides or fragrance around
the appliance.
Warning
Check if the voltage indicated on the
appliance corresponds to the local
power voltage before you connect the
appliance.
If the power cord is damaged, you must
have it replaced by Philips, a service
center authorized by Philips, or similarly
qualied persons in order to avoid a
hazard.
Do not use the appliance if the plug,
the power cord, or the appliance itself
is damaged.
This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved. Child shall not play with the
appliance. Cleaning and maintenance
shall not be made by children without
supervision.
Do not block the air inlet and outlet,
e.g. by placing items on the air outlet or
in front of the air inlet.
Make sure that foreign objects do not
fall into the appliance through the air
outlet.
Caution
This appliance is not a substitute for
proper ventilation or regular vacuum
cleaning.
If the power socket used to power the
appliance has poor connections, the
plug of the appliance becomes hot.
Make sure that you plug the appliance
into a properly connected power
socket.
Always place and use the appliance
on a dry, stable, level, and horizontal
surface.
Leave at least 20cm free space behind
and on both sides of the appliance and
leave at least 30cm free space above
the appliance.
Do not place anything on top of the
appliance.
Do not sit or stand on the appliance.
The appliance is equipped with omni
wheels. Sitting or standing on the
appliance may lead to potential injuiry.
Do not place the appliance directly
below an air conditioner to prevent
condensation from dripping onto the
appliance.
Make sure all lters are properly
installed before you switch on the
appliance.
5
EN
Only use the original Philips lters
specially intended for this appliance.
Do not use any other lters.
Avoid knocking against the appliance
(the air inlet and outlet in particular)
with hard objects.
Always lift or move the appliance
by both handles at the sides of the
appliance.
Do not insert your ngers or
objects into the air outlet or the air
inlet to prevent physical injury or
malfunctioning of the appliance.
Do not use this appliance when
you have used indoor smoke-type
insect repellents or in places with oily
residues, burning incense, or chemical
fumes.
Do not use the appliance near gas
appliances, heating devices or replaces.
Always unplug the appliance after use
and before cleaning or carrying out
other maintenance.
Do not use the appliance in a room
with major temperature changes, as
this may cause condensation inside the
appliance.
To prevent interference, place the
appliance at least 2m away from
electrical appliances that use airborne
radio waves such as TVs, radios, and
radio-controlled clocks.
This appliance is only intended to be
used indoor under normal operating
conditions.
Do not use the appliance in wet
surroundings or in surroundings with
high ambient temperatures.
The appliance does not remove carbon
monoxide (CO) or radon (Rn). It
cannot be used as a safety device in
case of accidents with combustion
processes and hazardous chemicals.
If you need to move the appliance,
disconnect the appliance from the
power supply rst. The appliance is
equipped with omni wheels and is easy
to move.
When moving the appliance, do it
slowly and do not push it rapidly.
Do not move the appliance by pulling
its power cord.
6
EN
2 Your air purifier
Read this user manual carefully before you use the appliance, and save it for future reference.
Product Overview
Air outlet cover
Speed knob
Filter 2: Integrated Filter
for Tai series
Filter 1: Pre-lter
Side panels
Air outlet cover knob
Air quality sensor
Type number Filter
TY5089 Integrated Filter for Tai series*
*Hereinafter referred to as "air purication lter".
7
EN
Controls overview
: On/Off button : Turbo speed
: Silent speed : Pre-lter cleaning alert
: Speed 1 : Air purication lter replacement alert
: Speed 2 : Air quality light button
: Speed 3 : Auto button
8
EN
3 Getting started
Installlters
Remove the packaging of the lters
before using the appliance. Unpack them
and place them back into the appliance
described as follows:
Note
There is one set of lters on each
side of the appliance. Each side is
equipped with one pre-lter and one air
purication lter.
Insert the lters in the correct position.
Make sure that you place the air
purication lter in the appliance rst
and then the pre-lter.
Make sure that the side with the tag is
pointing towards you.
1 Unlock the side panel from the
appliance, and then gently pull the
bottom of the side panel towards you.
2 To take out the pre-lter, press the
two clips down and pull the lter
towards you.
3 Take out the air purication lter from
the appliance.
4 Remove the packaging materials of the
air purication lter.
9
EN
5 Put the unpacked air purication lter
back into the appliance.
6 Put the pre-lter back into the
appliance.
Note
Make sure that the side with the two
clips is pointing towards you, and that
all hooks of the pre-lter are properly
attached to the purier.
7 To reattach the side panel, mount
the panel onto the bottom of the
appliance rst (1). Then, gently push
the panel against the body of the
appliance (2).
8 Repeat all steps for the other side of
the appliance.
10
EN
4 Using the appliance
Understand the air quality
light
Color of the air quality
light
Air quality level
Blue Good
Dark purple Fair
Pink Unhealthy
Red Very unhealthy
The air quality light automatically goes on
when the appliance is switched on, and
lights up all colors in sequence. In a short
while the air quality sensor selects the
color that corresponds to the ambient air
quality.
Note
The built-in air quality sensor measures
the air quality and automatically selects
the appropriate color of the air quality
light. When the air is clean, the color of
the air quality light is in blue. When the
air quality deteriorates, the color of the
air quality light changes to dark purple,
purple or red.
Switch on
1
Put the plug of the appliance into the
wall socket.
» The appliance beeps.
» All lights go on once and then go
out again.
2 Press to switch on the appliance.
» After measuring the air quality
for a short time, the air quality
sensor automatically selects
the appropriate color of the air
quality light.
» The default fan speed is
(AUTO).
3 Press again to switch off the
appliance.
11
EN
Change the fan speed
(AUTO)
In auto mode, the appliance selects the
appropriate fan speed in accordance with
the ambient air quality.
1 Press to select the auto mode.
» and one of the fan speed
indicators light up.
2 Press again to deactivate the auto
mode.
» The appliance operates in manual
mode.
Note
You can also turn the speed knob and
select another fan speed to switch from
auto mode to manual mode.
Manual
You can mannually select the fan speed
you need.
1 Turn the speed knob to select the fan
speed:
(Speed 1)
(Speed 2)
(Speed 3)
(Silent speed)
(Turbo speed)
Tip
If the air quality light lights up blue, the
air quality is good, and you can select a
lower fan speed. On the other hand, if
the air quality light lights up pink or red,
the air quality is unhealthy, and you can
select a higher fan speed to purify the
air more quickly.
12
EN
Fan speed light Sensitivity level
Extra sensitive
Sensitive
Standard
2 Turn the speed knob to adjust the
sensitivity level of the air quality sensor.
3 When the desired sensitivity level is
selected, press and hold and for
3 seconds again to save the setting.
Note
When you are changing the sensitivity
level, if you do not change any setting
within 10 seconds, or do not press and
hold
and for 3 seconds after
you have changed the sensitivity level,
the appliance will resume normal work
without saving any changes.
After the sensitivity level is changed
and saved, the appliance operates at
the latest setting of the sensitivity level
whenever you switch on the appliance.
Set the sensitivity of the air
quality sensor
This appliance allows you to adjust the
sensitivity of the air quality sensor. There
are three sensitivity levels:
Extra sensitive (default setting)
Sensitive
Standard
You can adjust the sensitivity of the air
quality sensor in the following way:
Note
At higher sensitivity level, the purier
is more sensitive to air pollutants.
When the purier is in auto mode, it
is more likely to choose a higher fan
speed. The air quality sensor selects the
appropriate color of the air quality light
in accordance with the higher sensitivity.
1 Unplug the appliance rst, plug it in
again and switch it on. Within 5 to 30
seconds from the appliance is switched
on, press and hold and for 3
seconds.
» The corresponding fan speed
light ashes to show the current
sensitivity level of the air quality
sensor.
3
3S
13
EN
5 Cleaning
Note
Always unplug the appliance before you
clean it.
Never immerse the appliance in water
or any other liquid.
Never use abrasive, aggressive, or
ammable cleaning agents such as
bleach or alcohol to clean any part of
the appliance.
Only the pre-lter is washable. The
air purier lter is not washable nor
vacuum cleanable.
Cleaning schedule
Frequency Cleaning method
When necessary Wipe the surface of
the appliance with a
soft dry cloth.
Clean the air outlet
cover
Every two
months
Clean the air quality
sensor with a dry
cotton swab.
When the lter
cleaning indicator
lights up
Clean the pre-lter.
When the lter
replacement
indicator
starts ashing
Replace the air
purication lter.
Clean the body of the
appliance
Regularly clean the inside and outside
of the appliance to prevent dusts from
collecting.
1 Wipe away dust with a soft dry cloth
from the body of the appliance.
2 Clean the air inlet and the air outlet
with a soft dry cloth.
Clean the air outlet cover
1
To unlock the air outlet cover, turn the
cover knob clockwise, and pull up the
cover to remove.
2 Clean the cover with a brush.
14
EN
3 To reattach the cover, mount it onto
the top of the appliance rst, and then
turn the cover knob anti-clockwise to
lock the cover.
Clean the air quality sensor
Clean the air quality sensor every two
months for optimal functioning of the
appliance. Clean it more frequently if you
use the appliance in a dusty environment.
1 Clean the inlet and outlet of the air
quality sensor with a soft brush.
2 Open the cover of the air quality
sensor.
3 Clean the sensor, the dust inlet and
outlet with a lightly moistened cotton
swab, and nish with a dry cotton
swab.
4 Close the sensor cover.
15
EN
Cleanthepre-lter
Filter alert light status Follow this
lights up.
Clean the pre-lter
Note
Filter light
lights up approximately once a
month.
1 Call the Philips Consumer Care
Center (4009200180) immediately to
clean the pre-lter.
16
EN
6 Replacingtheair
purification filter
Understand the healthy air
protect lock
This appliance is equipped with the healthy
air protect lock to make sure that the
lters are in optimal condition when the
appliance is operating. When the lter is
almost full and has to be replaced, the air
purication lter replacement light ( )
starts to ash.
When you do not replace the lter in time:
» The air purication lter
replacement light ( ) remains
on.
» The appliance stops operating
and is locked. Call the Philips
Consumer Care Center
(4009200180) immediately to
replace the lter.
Replacetheairpurication
lter
Filter alert light
status
Follow this
lights up.
Replace the air
purication lter.
Note
The air purication lter is not washable
nor vacuum cleanable.
1 Take out the pre-lters on both sides
of the appliance.
2 Take out the air purication lter on
both sides of the appliance using the
tag on the lter and gently put them
into the trash bin.
17
EN
Note
Do not touch the pleated lter surface,
or smell the lter as it has collected
pollutants from the air.
Wash your hands after disposing of the
used lters.
3 Remove all packaging material of the
new lters.
4 Put the new lters into the appliance
on both sides.
5 After the pre-lters are properly put
back in the appliance, reset the lter
lifetime counter. (Refer to chapter 7
"Resetting the lter lifetime counter".)
7 Resetting the filter
lifetime counter
When you replace the lters, it is
important that you also reset the lter
lifetime counter afterwards. This allows
the appliance to be in sync with the lter
lifetime.
1 Press and hold for 3 seconds.
» The lter light goes out, and
the appliance resumes working
automatically.
3
3S
18
EN
8 Troubleshooting
This chapter summarizes the most common problems you could encounter with the
appliance. If you are unable to solve the problem with the information below, contact the
Consumer Care Center in your country.
Problem Possible solution
The appliance does
not work even
though it is plugged
in.
The lter replacement light has been on continuously but you did
not replace the corresponding lter, it is now locked. In this case,
replace the lter and reset the lter time.
No air comes out of
the air outlet.
Put the plug of the appliance into the power socket and switch on.
The airow that
comes out of the air
outlet is signicantly
weaker than before.
The pre-lter is dirty. Clean the pre-lter (see the chapter
"Cleaning").
Make sure that you have removed all packaging material from the
lters.
The air quality does
not improve, even
though the appliance
has been operating
for a long time.
One of the lters has not been placed in the appliance. Make
sure that all lters are properly installed in the following order,
starting with the innermost lter: 1) air purication lter; 2) pre-
lter.
The air quality sensor is wet. The humidity level in your room
is high and causes condensation. Make sure that the air quality
sensor is clean and dry (see the chapter "Cleaning").
The color of the air
quality light always
stays the same.
The air quality sensor is dirty. Clean the air quality sensor (see the
chapter "Cleaning").
The appliance
produces a strange
smell.
The rst few times you use the appliance, it may produce a plastic
smell. This is normal. However, if the appliance produces a burnt
smell, contact your Philips dealer or an authorized Philips service
centre. The appliance may also produce an unpleasant smell when
one of the lters is dirty. In this case, clean or replace the lter
concerned.
19
EN
Problem Possible solution
I need cleaner air
because I have an
allergy.
You can change the air quality sensor sensitivity (see the chapter
"Use the appliance, section "Set the sensitivity of the air quality
sensor") to make the appliance clean the air even better.
The appliance is
extra loud.
Please check if you have removed all the packaging material from
the lters.
If the appliance is still too loud, you can change the fan speed to a
lower fan speed level.
The appliance still
indicates that I need
to replace a lter, but
I already did.
Perhaps you did not reset the lter lifetime counter. Switch on the
appliance. Then press and hold
for 3 seconds.
20
EN
9 Guarantee and
service
If you need information or if you have
a question, please contact the Philips
Consumer Care Center in your country
(4009200180). If there is no Consumer
Care Center in your country, go to your
local Philips dealer.
Order parts or accessories
If you have to replace a part or want to
purchase an additional part, please contact
the Philips Consumer Care Center in your
country (4009200180).
10 Notices
Electromagneticelds(EMF)
This Philips appliance complies with all
applicable standards and regulations
regarding exposure to electromagnetic
elds.
Compliance with EMF
Koninklijke Philips N.V. manufactures and
sells many products targeted at consumers,
which, like any electronic apparatus, in
general have the ability to emit and receive
electromagnetic signals.
One of Philips' leading Business Principles
is to take all necessary health and safety
measures for our products, to comply with
all applicable legal requirements and to stay
well within the EMF standards applicable at
the time of producing the products.
Philips is committed to develop, produce
and market products that cause no
adverse health effects. Philips conrms
that if its products are handled properly
for their intended use, they are safe to use
according to scientic evidence available
today.
Philips plays an active role in the
development of international EMF
and safety standards, enabling Philips
to anticipate further developments in
standardization for early integration in its
products.
Recycling
Do not throw away the product with the
normal household waste at the end of its
life, but hand it in at an ofcial collection
point for recycling. By doing this, you help
to preserve the environment.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Philips TY5080/00 ユーザーマニュアル

カテゴリー
空気清浄機
タイプ
ユーザーマニュアル

他の言語で

その他のドキュメント