Dell PowerEdge T110 II クイックスタートガイド

カテゴリー
サーバー
タイプ
クイックスタートガイド
Dell PowerEdge
T110 II Systems
Getting Started
With Your System
系统使用入门
開始使用系統
Memulai Dengan Sistem Anda
はじめに
시스템 시작 안내서
Dell PowerEdge
T110 II Systems
Getting Started
With Your System
Regulatory Model E11S Series
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better
use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss
of data if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage,
personal injury, or death.
____________________
Information in this publication is subject to change without notice.
© 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc.
Intel
®
and Xeon
®
are registered trademarks of Intel Corporation in the U.S. and other countries.
Microsoft
®
and Windows Server
®
are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries. Red Hat
®
and Red Hat
Enterprise Linux
®
are registered trademarks of Red Hat, Inc. in the United States and other countries.
VMware
®
is a registered trademark of VMWare, Inc. in the United States or other countries.
Citrix
®
and XenServer
®
are registered trademarks of Citrix Systems, Inc. in the United States and/or
other countries. SUSE ™
is a trademark of Novell, Inc. in the United States and other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Model: E11S Series
December 2010 P/N DHY8H Rev. A01
Getting Started With Your System 3
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item.
Optional—Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable
to plug into each connector. Be sure to tighten the screws (if any) on the
monitor's cable connector.
4 Getting Started With Your System
Connecting the Power Cable
Connect the system’s power cable to the system and, if a monitor is used,
connect the monitor’s power cable to the monitor.
Securing the Power Cable
Bend the system power cable into a loop, as shown in the illustration,
and attach to the cable clasp.
Plug the other end of the power cable into a grounded electrical outlet or a
separate power source such as an uninterruptible power supply (UPS) or a
power distribution unit (PDU).
NOTE: Ensure that the system is connected to a stand-alone power source with
stable power supply for better performance.
Getting Started With Your System 5
Turning On the System
Press the power button on the system. The power indicator should light.
Complete the Operating System Setup
If you purchased a preinstalled operating system, see the operating system
documentation that ships with your system. To install an operating system for
the first time, see the installation and configuration documentation for your
operating system. Be sure the operating system is installed before installing
hardware or software not purchased with the system.
Supported Operating Systems
Microsoft Windows Small Business Server 2011 (x64) Standard and
Essential Editions
Microsoft Windows Server 2008 R2 SP1 (x64) Standard and
Foundation Editions
Microsoft Windows Server 2008 R2 (x64) Standard and
Foundation Editions
Microsoft Windows Server 2008 (x86) Standard Edition with SP2
Microsoft Windows Server 2008 (x64) Standard Edition with SP2
Microsoft Windows Server 2008 R2 SP1 (x64) with Hyper-V for
Standard Edition
6 Getting Started With Your System
Microsoft Windows Server 2008 SP2 (x64) with Hyper-V for
Standard Edition
Microsoft Windows Server 2008 R2 (x64) with Hyper-V for
Standard Edition
Red Hat Enterprise Linux Server 6.0 (x64)
•SUSE
Linux Enterprise Server 11 SP1 (x64)
VMware ESX Version 4.1 Update 1 (Classic)
VMware ESXi Version 4.1 Update 1 (Embedded)
Citrix XenServer v5.6 Feature Pack 1
NOTE: For the latest information on supported operating systems,
see support.dell.com.
Dell Software License Agreement
Before using your system, please read the Dell Software License
Agreement that came with your system.
You must consider any CD, DVD, or diskette set of Dell installed
software as BACKUP copies of the software installed on your
system’s hard-disk drive.
If you do not accept the terms of the agreement, please call the customer
assistance telephone number. For customers in the United States,
call 800-WWW-DELL (800-999-3355). For customers outside the
United States, visit
support.dell.com
and select your country or region
from the top of the page.
Getting Started With Your System 7
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document or
as a separate document.
The
Owner’s Manual
provides information about system features
and describes how to troubleshoot the system and install or replace
system components. This document is available online at
support.dell.com/manuals
.
Any media that ships with your system that provides documentation and tools
for configuring and managing your system, including those pertaining to the
operating system, system management, system updates, and system
components that you purchased with your system.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does not
perform as expected, see your Owner’s Manual. Dell offers comprehensive
hardware training and certification. See dell.com/training for more information.
This service may not be offered in all locations.
Información de la NOM (sólo para México)
La información que se proporciona a continuación aparece en el dispositivo
descrito en este documento, en cumplimiento de los requisitos de la Norma
Oficial Mexicana (NOM):
Importador:
Número de modelo: E11S
Voltaje de alimentación: 100 V CA–240 V CA
Frecuencia: 50 Hz/60 Hz
Consumo eléctrico: 9.0 A–4.5 A
8 Getting Started With Your System
Technical Specifications
Processor
Processor type One Intel Xeon processor E3-1200 product family
or
One Intel Core i3-2100 product family
or
One Intel Pentium processor (when available)
Expansion Bus
Bus type PCI Express Generation 2
Expansion slots Slot 1: PCIe x8 (x8 routing), half-length
Slot 2: PCIe x16 (x8 routing), full-length
Slot 3: PCIe x8 (x4 routing), half-length
Slot 4: PCIe x1 (x1 routing), half-length
Memory
Architecture 1066 MHz or 1333 MHz DDR3 unbuffered Error
Correcting Code (ECC) DIMMs
Memory module sockets Four 240-pin
Memory module capacities 1 GB, 2 GB, 4 GB, or 8 GB
Minimum RAM 1 GB
Maximum RAM 32 GB
Drives
Hard drives Up to four 3.5-inch, cabled SAS or SATA
internal drives
Optical drive Optional internal SATA DVD-ROM or
SATA DVD+/-RW
Optional external USB DVD-ROM
NOTE: DVD devices are data only.
Tape drive One optional internal half-height tape
backup device
Getting Started With Your System 9
Connectors
Back
NIC
One RJ-45 (for integrated 1 GB NIC)
Serial
9-pin, DTE, 16550-compatible
USB
Four 4-pin, USB 2.0-compliant
Video
15-pin VGA
eSATA
One 7-pin connector
Front
USB
Two 4-pin, USB 2.0-compliant
Internal
USB
Two 4-pin, USB 2.0-compliant
Video
Video type Matrox G200, integrated in Winbond WPCM450
Video memory 8 MB
Power
AC power supply (per power supply)
Wattage
305 W
Voltage
100 VAC–240 VAC, 50 Hz/60 Hz, 9.0 A–4.5 A
Heat dissipation
1300 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 35 A per power supply for
10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium coin cell
10 Getting Started With Your System
Physical
Height 42.03 cm (16.55 in)
Width 18.90 cm (7.44 in)
Depth 46.38 cm (18.25 in)
Weight 16.1 kg (35.49 lb)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Temperature
Operating
10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
Storage
–40 °C to 65 °C (–40 °F to 149 °F) with
a maximum temperature gradation
of 20 °C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 Grms at 5 Hz–350 Hz for 15 min
Storage
1.87 Grms at 10 Hz–500 Hz for 15 min
Getting Started With Your System 11
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms in
the operational orientation
Storage
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of 71 G for
up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 32 G faired square
wave pulse with velocity change at
270 inches/second (686 centimeters/second)
Altitude
Operating
–16 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
Storage
–16 m to 10,600 m (–50 ft to 35,000 ft)
Airborne contaminant level
Class
G1 as defined by ISA-S71.04-1985
Environmental (continued)
12 Getting Started With Your System
Dell PowerEdge
T110 II 系统
系统使用入门
管制型号
E11S
系列
注、小心和警告
注:“注”表示可以帮助您更好地使用计算机的重要信息。
小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据
丢失。
警告:
“警告”表示可能会导致财产损失、人身伤害甚至死亡。
____________________
本出版物中的信息如有更改,恕不另行通知。
© 2010 Dell Inc.
版权所有,翻印必究。
未经
Dell Inc.
书面许可,严禁以任何形式复制这些材料。
本文中使用的商标
Dell
DELL
徽标和
PowerEdge
Dell Inc.
的商标。
Intel
®
Xeon
®
Intel Corporation
在美国
和其它国家
/
地区的注册商标。
Microsoft
®
Windows Server
®
Microsoft Corporation
在美国和
/
或其它国家
/
地区的商标或注册商标。
Red Hat
®
Red Hat
Enterprise Linux
®
Red Hat, Inc.
在美国和其它国家
/
地区的注册商标。
VMware
®
VMWare, Inc.
在美国或其它国家
/
地区的注册商标。
Citrix
®
XenServer
®
Citrix
Systems, Inc.
在美国和
/
或其它国家
/
地区的注册商标。
SUSE
Novell, Inc.
在美国和其它
国家
/
地区的商标。
本出版物中述及的其它商标和商品名称是指拥有相应商标和商品名称的公司或其产品。
Dell Inc.
对其它公司的商标和产品名称不拥有任何所有权。
管制型号:
E11S
系列
2010
12
P/N DHY8H Rev. A01
系统使用入门 15
安装和配置
警告:
执行下列步骤之前,请查看系统随附的安全说明。
打开系统包装
打开系统包装并检查各个组件。
可选
连接键盘、鼠标和显示器
连接键盘、鼠标和显示器(可选)。
系统背面的连接器附有图标,这些图标指示了要插入每个连接器的电缆。
确保拧紧显示器的电缆连接器上的螺钉(如果有)。
16 系统使用入门
连接电源电缆
将系统电源电缆连接至系统,如果使用显示器,将显示器电源电缆连接至显
示器。
固定电源电缆
如图例所示,将系统电源电缆弯曲成环状,并连接至电缆挂钩。
将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设备
(UPS)
或配电装置
(PDU)
注:为获得最佳的性能,请确保使用稳定的电源设备将系统连接至独立的
电源。
系统使用入门 17
开启系统
按下系统上的电源按钮。电源指示灯将会亮起。
完成操作系统安装
如果购买了预安装的操作系统,请参阅系统随附的操作系统说明文件。第一
次安装操作系统时,请参阅操作系统的安装和配置说明文件。请确保先安装
操作系统,然后再安装未随系统一起购买的硬件或软件。
支持的操作系统
Microsoft Windows Small Business Server 2011 (x64) Standard
版及
Essential
Microsoft Windows Server 2008 R2 SP1 (x64) Standard
版及
Foundation
Microsoft Windows Server 2008 R2 (x64) Standard
版及
Foundation
Microsoft Windows Server 2008 (x86) Standard
版(附带
SP2
Microsoft Windows Server 2008 (x64) Standard
版(附带
SP2
具有
Hyper-V
Microsoft Windows Server 2008 R2 SP1 (x64) Standard
具有
Hyper-V
Microsoft Windows Server 2008 SP2 (x64) Standard
具有
Hyper-V
Microsoft Windows Server 2008 R2 (x64) Standard
Red Hat Enterprise Linux Server 6.0 (x64)
18 系统使用入门
SUSE
Linux Enterprise Server 11 SP1 (x64)
VMware ESX
版本
4.1 Update 1
(经典)
VMware ESXi
版本
4.1 Update 1
(嵌入式)
Citrix XenServer v5.6 Feature Pack 1
注:有关支持的操作系统的最新信息,请访问 support.dell.com
Dell
软件许可协议
在使用您的系统前,请阅读系统随附的
Dell
软件许可协议。
您必须将
Dell
安装的软件的任何
CD
DVD
或套装软盘视为您系统硬
盘驱动器上安装的软件的备份副本。
如果您不接受协议条款,请拨打客户帮助电话号码。美国地区的客
户,请致电
800-WWW-DELL (800-999-3355)
。美国以外的客户,请访
support.dell.com
并从页面顶部选择您的国家或地区。
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

Dell PowerEdge T110 II クイックスタートガイド

カテゴリー
サーバー
タイプ
クイックスタートガイド