Use the Optional Ionizer
2
Before using
For note and safety, refer to the instruction manual of UJF-
3042MkIIseries/6042MkIIseries printer. Before using, be sure
to read “Warning and Note” of this manual and fully
understand its contents.
Unauthorized reproduction of any portion of this document is
strictly prohibited.
© 2016 MIMAKI ENGINEERING Co., Ltd.
It is recommended to check the effect of removing electricity
in advance.
Setting the Ionizer
When set the ionizer "ON" in the MACHINE SETUP, it will
perform the static elimination operation before print.
1Press
(MENU) (>>
) in local.
2Press to select “MACHINE SETUP”
and press the key.
• MACHINE SETUP MENU will be displayed.
3Press to select “IONISER” and
press the key.
• “IONISER” setting will be selected.
4Press to select “ON” and press the
key.
• When set to “ON” , the table moves the entire surface
according to the print data in order to eliminate static
prior to print.
5Press the key several times to
end the setting.
About daily care
Tools required for maintenance
• Electrode Probe Cleaning Kit (SPA-0237/SPA-0239)
• Goggles
• Alcohol
•Gloves
Cleaning the Electrode Probe
Check the electrode probe before operation and clean it if it is
dirty.
1Remove the electrode probe from the ionizer.
• By using the attached electrode probe replacement
kit, you can remove it easily.
(1) Put the replacement kit to the electrode probe.
(2) Remove the electrode probe.
2Wipe off the electrode probe and around it
with a cotton swab immersed in alcohol.
• Recommended: ethyl alcohol
• It is possible that enough effect cannot be achieved
depending on your using environment or the media.
• Do not touch directly on the electrode probe during
use or in the middle of static elimination. There is a
risk of injury. Please working with care.
• Do not touch the electrode probe in hard material,
such as a tool during use or in the middle of static
elimination. This may cause a malfunction or
accident.
• Before taking care of it, be sure to turn off the main
power switch of the main body.
You may get an electric shock. Also, you may get
injured collaterally.
• Do not touch the electrode probe directly. You may
get injured. Be careful to work.
• After cleaning, fully dry it and then attach it to the
ionizer to use.
• When washing liquid remains on the electrode probe,
it may cause an accident or failure of the
machine.The cleaning alcohol may touch your skin or
get in your eyes.
• Do not touch the electrode probe with a hard thing
such as a tool. It may cause an accident or failure of
the machine.
• Do not touch the electrode probe directly. You may
get injured. Be careful to work.
• Do not touch the electrode probe with a hard thing
such as a tool. It may cause an accident or failure of
the machine.
When it is very dirty
• Use an ultrasonic bath.
Also, you can use alcohol as washing liquid.