EcoFlow 110W Solar Panel ユーザーガイド

タイプ
ユーザーガイド
SOLAR PANEL
Contact Us:
support@ecoflow.com
www.ecoflow.com
In The Box
How It Works
Protective Case
and kickstand
MC4 Output Controller
EcoFlow RIVER
(Sold Separately)
EcoFlow RIVER
(Sold Separately)
EcoFlow DELTA
(Sold Separately)
EcoFlow DELTA
(Sold Separately)
Solar Charging Cable
(Sold Separately)
XT60
INPUT PORT
Solar Panel
Solar Panel
Solar Panel
User Manual
& Warranty Card
Snap Hook
x 4
Your Solar Setup
1
2
3
4
5
6
To harvest solar energy most eciently,
try to ensure that the sun's rays hit the
panel at a 90°angle and that the panel
is not shaded.
For improved charging results, the Protective Case can also beused as a kickstand to propup the
solar panel at a 25°–80°angle.
Adjust The Angle By Shooting
Solar Panel
MC4
Adapter Cable
1. Connect the positive poles of the two solar panels with the MC4
  parallel cable and repeat the step for the negative poles.
2. Connect the parallel cable connectors (output side) with the   
  MC4 connectors of the Solar Charging Cable (MC4 to XT60  
  cable) respectively.
3. Connect the XT60 connector on the Solar Charging Cable(MC4  
  to XT60 cable) to the XT60 port on the portable power station  
  to recharge the unit.
(refer to the figure below)
Wire solar panels in parallel
Speed Up Solar Charging
Solar MC4 parallel connection cable
Solar Panel A Solar Panel B
MC4
* Users have to buy the solar panels and other
parallel connection accessories seperately.
7
The kickstand feature should only be
used before 10:00am or after 2:00pm.
To use the product during the midday
sun, simply place the solar panel flat on
the ground.
1 1
1 1
2
2
3
*For more information and methods about solar charging,please
refer to the user manual of the specific portable power station.
1. Snap the male connector of one solar panel into the female
 connector of the other respectively to wire the three solar panels
 
 in series.
2. Wire the two connectors that are unwired in step 1 with the Solar
 Charging Cable (MC4 to XT60 cable) respectively.
3. Connect the XT60 connector on the Solar Charging Cable (MC4
 to XT60 cable) to the XT60 port on the portable power station
 to recharge the unit.
(refer to the figure below)
Wire solar panels in series
Avoid
Behaviors above that demage the solar panel, will cause the cell inside the solar panel to crack and ecien-
cy drop, or even unusable. The free warranty period does not cover damage resulting from improper use of
the product.
Supported
Product 110W
RIVER mini
RIVER Series
DELTA mini
DELTA
DELTA Max
DELTA Pro
1
1
4
6
3
3
Max. No. Of Panels Connected in
Series to Supported Products
1
2
3
2
1
*For more information and methods about solar charging,please
refer to the user manual of the specific portable power station.
MC4
Things to Remember When Using Solar Panel
1. As the eciency of solar panels depends upon light intensity and the tilt angle used, the charging power
of the panel may be aected by a number of factors such as weather conditions, seasonal changes and
location. The installation and connection of this product should be carried out strictly in accordance with
the instructions found in the User Manual.
2. Only the main body of this product is waterproof. The junction box and connection points should not be
immersed in water.
3. This product must not come into contact with highly corrosive substances, or be immersed in corrosive
liquids.
4. To avoid damaging the product, do not use sharp objects on the surface of the panel, and do not knock or
impact the product.
5. Do not apply pressure to the panel or allow the panel to be dropped on any of its corners, sides or faces.
Such actions may result in damage to the solar panel.
6. The panel must not be knocked, exposed to heavy pressure, or bent during transport, rotation or installa-
tion. We recommend that the panel is kept in a vertical position when being moved or stored.
7. When storing the panel, always ensure that the positive and negative terminals of the junction box are not
exposed to sunlight.
8. To avoid the risk of injury, this product and its junction box must only be opened or disassembled by
qualified personnel.
9. Unwanted solar panels must be disposed of in accordance with the local legal requirements.
4. Panel Shading. The surface of the solar panel should not be shaded during use. Shading caused by
shadows, foreign objects and glass can all greatly reduce power output.
What should I know about the operating temperature, storage and use of the 110W Solar
Panel?
The operating temperature of the Solar Panel is -20°C–85°C (-4°F–185°F). The panel should be
folded into its original shape and stored in its Protective Case (Kickstand), which provides sucient
protection for the product. To extend the service life of the panel, ensure that the product is not exposed to
external forces/impacts when not in use. The solar panel must not be dropped, pierced, bent, or sat on.
These actions may break the cell and render the panel unusable. Any such damage will not be covered by
the free warranty.
Performance Issues Caused by Malfunctioning Panels: If the panel still isn’t generating power or its output
remains far below expected nominal power figures after addressing the issues above, there may be an issue
with the panel itself. Please contact Customer Support for assistance.
FAQs
Does the 110W Solar Panel generate a full 110W of power?
In most cases, it is normal for a solar panel not to deliver its full nominal power. Some of the reasons why
this happens, as well as some suggestions for getting closer to the nominal power figure, are given below.
1. Light Intensity. The amount of light shining on the panel will result in fluctuations to the power output.
You are more likely to achieve nominal power output figures closer to those obtained under test conditions
when using the product on a clear day during the midday sun, than when using the product in the morning
or later in the afternoon. Weather conditions will also aect the amount of sunlight that shines on the
panel. For example, you are much less likely to achieve the figures for nominal power in hazy, cloudy or
rainy conditions.
2. Surface Temperature. The temperature of the solar panel surface will also aect the amount of power
generated. The lower the surface temperature of the panel, the more power will be produced. For
example, solar panels generate more power when used during the winter than during the summer, and
this is completely normal. Solar panels generally reach temperatures close to 60°C (140°F) during
summer. This reduces nominal power by 13%, despite the higher levels of light shining on the panel.
3. Sunlight Angle. In optimal light conditions, the sun’s rays should remain perpendicular to the surface
of the panel for best performance. The dierence of ± 10 degrees of 90 degrees of sunlight hitting the
panels has little eect on the power.
How much power can the 110W Solar Panel generate under normal conditions?
This depends first and foremost on weather conditions. Generally speaking, on a clear day with no clouds in
the sky, sunlight hitting the panel at a 90° angle usually generates 88W–90W of power in the 110W panel.
(Current light conditions are normally 800W–900W/m² (74.3W–83.6W/ft²) with a panel temperature of 50°C (122°F)
under test conditions. Nominal power ratings are based on 1000W/m² (92.9W/ft²) in AM1.5 conditions with a panel
temperature of 25°C (77°F) under test conditions. Power output figures close nominal values were normally observed in
the midday sun during the winter.)
Can I use non-EcoFlow branded power stations with the 110W Solar Panel?
Yes, but only certain types. The power station used must be compatible with MC4 standards in order to
work properly. In addition, other brands of power station may not oer the same levels of compatibility as
EcoFlow-branded power stations, may have lower nominal power ratings, and may not oer the same levels
of performance.
Can I connect 110W Solar Panels in parallel?
Yes, but this is not recommended. Parallel connections will double the total current of the input power.
110W solar panels can be connected in parallel, but the current may exceed the input current limitation of
the power station. Only two 110W panels should be used in parallel connection.
If you want to connect more than two 110W panels with parallel connection, ensure the maximum solar input
current of your power station is higher than 20A.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
FCC STATEMENT
Can I connect 110W Solar Panels with another size of solar panels in series?
Yes, but this is not recommended. Even if the voltage of the two panels are identical, the current ratings are
not. This means that when the panels are connected in series, the current will be limited to that of the lower
solar panel which cause the power of 110W solar panel can’t be released entirely, resulting in a 1+1<2 scenario.
Please purchase panels of the same size if you intend to connect multiple panels in series.
Technical Specifications
110W Solar Panel
General
Rated Power: 110W(+/-5W)*
Open Circuit Voltage: 21.8V
Running Voltage: 18.4V
Short Circuit Current: 6.5A
Running Current: 6.0A
Efficiency: 22.4%-22.8%
Cell Type: Monocrystalline silicon
Connector type: MC4
Weight: Approximately 13.2 lbs (6KG)
Solar Panel: Approximately 8.8lbs (4KG)
Unfolded Dimensions:
16.5*70.3*1.0 in(42.0*178.5*2.5 cm)
Folded Dimensions:
16.5*18.9*1.0 in(42.0*48*2.5 cm)
Warranty: 12 months
*Warranty period may vary according to local laws and regulations.
*Standard Test Conditions:1000W/m2, AM1.5, 25°C
Temperature Coecient Specifications
TKPower -(0.39±0.02)%/k
TKVoltage -(0.33±0.03)%/k
TKCurrent +(0.06±0.015)%/k
お問い合わせ :
support.jp@eco󼵡ow.com
https://jp.eco󼵡ow.com
ソーラーパネル
同梱物
ソーラーパネルの使用方法
保護ケース
( キックスタンド )
MC4 出力コントローラ
ソーラーパネル EcoFlow RIVER
( 別売り )
EcoFlow RIVER
( 別売り )
EcoFlow DELTA
( 別売り )
EcoFlow ポータブル電源を充電する方法
デバイスを充電する方法
EcoFlow DELTA
( 別売り )
ソーラー充電ケーブル
(EcoFlow ポータブル電
源の同梱物です )
XT60
入力ポート
製品本体 ユーザーマニュアル
& 保証書
ソーラーパネル
スナップ
フック x4
ソーラーパネルの設置方法
1
2
3
4
5
6
太陽エネルギーを最も効率的集めるために 、 ソー
ラーパネルに影がかからず 、 太陽光線が 90º の角
度で当たるようにすることをご確認ください 。
充電効率を向上させるために、保護ケースをキックスタンドとして使用し 25º ~ 80º の角度でソーラーパネル
を支えることは可能です。
ジッパーでキックスタンドの角度を調節します
ソーラー
パネル
ソーラーパネル
充電ケーブル
ソーラーパネル用
二股ケーブル ( 別売り )
ソーラーパネル A ソーラーパネル B
1、ソーラーパネル用二股ケーブルでソーラーパネル A とソーラーパネル B の MC4 コネクタ
を接続する ( 下図➀をご参照 )。
2、EcoFlow ポータブル電源に同梱のソーラーパネル充電ケーブルの MC4 コネクタをソーラーパネ
ルと接続済みの二股ケーブルの MC4 コネクタに繋げる ( 下図➁をご参照 )。
3、ソーラーパネル充電ケーブルの XT60 コネクタを EcoFlow ポータブル電源の XT60 端子に接続し、
EcoFlow ポータブル電源に給電する ( 下図➂をご参照 )。
( 下記画像ご参考 )
並列接続方法
充電速度を速くする
7
キックスタンド機能は 、 午前 10 時より前または
午後 2 時以降にのみ使用してください 。
正午の太陽の下で本製品を使用するには 、 ソーラ
ーパネルを平にして地面に置きます 。
sw
1 1
1 1
2
2
3
*EcoFlow 社以外のソーラーパネルをご利用の場合、お使いの製品のユーザーガイドをご参考ください。
MC4 コネクタ
1、ソーラーパネル本体に付属している MC4 出力ケーブルでソーラーパネル同士を接続する
( 下図➀をご参照 )。
2、EcoFlow ポータブル電源に同梱のソーラーパネル充電ケーブルの MC4 コネクタをソーラ
ーパネル側の MC4 出力ケーブルに繋げる ( 下図➁をご参照 )。
3、ソーラーパネル充電ケーブルの XT60 コネクタを EcoFlow ポータブル電源の XT60 端子に
接続し、EcoFlow ポータブル電源に給電する ( 下図➂をご参照 )。
(下記画像ご参考)
直列接続方法
*EcoFlow 社以外のソーラーパネルをご利用の場合、お使いの製品のユーザーガイドをご参考く
ださい。
110W
対応可能な製品
RIVER mini
RIVER シリーズ
DELTA mini
DELTA
DELTA Max
DELTA Pro
1
1
3
4
3
6
対応可能な製品に直列で接続できる
ソーラーパネルの最大枚数
禁止事項
以上の行為は製品を損傷して使用できなくなり、内蔵セルの破損と発電効率の低下の原因になります。無償保証は、製
品の不適切な使用による損傷には適用されません。予めご了承ください。
1
2
3
2
1
MC4 コネクタ
ソーラーパネル使用時の注意事項
1. ソーラーパネルの効率が光強度と傾きの角度によって異なるため、発電量は天候条件、季節の変化、場所などのさま
ざまな要因によって影響を受ける場合があります。ソーラーパネルの設置と接続はユーザーマニュアルに記載されて
いる手順に厳密に従って行う必要があります。
2. 本製品は本体のみが防水仕様になっています。MC4 出力コントローラの部分は、水に浸さないでください。
3. 本製品は腐食性の高い物質との接触や腐食性の液体への浸漬を避けてください。
4. 製品の損傷を防ぐため、刃物など鋭利なもので突き刺したり、製品を叩いたり、衝撃を与えたりしないでください。
5. 損傷のおそれがありますので、製品に圧力をかけたり、製品を落としたりしないでください。
6. 輸送または設置を行うときに、製品をぶつけたり、強い圧力をかけたり、曲げたりしないでください。移動または保
管するときは、製品を垂直ににすることをお勧めします。
7. 保管する時、必ずジャンクションボックスのプラス・マイナス端子を日光に当たらないように納めてください。
8. けがするおそれがありますので、製品を開いたり、分解したりしないでください。
9. 製品を廃棄する際、お住まいの自治体に廃棄方法をお問い合わせください。
FAQ
EcoFlow 110W ソーラーパネルが 110W の出力で発電できますか?
通常、ソーラーパネルが完全な公称電力を供給しないのは正常です。公称電力が供給されない理由と公称電力値に近づ
けるためのいくつかの提案を以下に示します。
1. 光の強度。ソーラーパネルに射される日光の量によって、発電量が変わります。快晴の日に真昼の太陽の下で製品を
使用すると、朝または夕方近くに使用する場合より、標準試験条件下で得られた公称電力に近い出力値を得る可能性
が高くなります。また、天候条件も日光の量に影響します。例えば、もや、曇り、雨などの条件下では、公称電力の
出力値を得る可能性は遥かに低くなります。
2. 表面温度。ソーラーパネル表面の温度も発電量に影響します。表面温度が低いほど、より多くの電力が生成されます。
例えば、夏より、冬に使用した方がソーラーパネルはより多く発電できます。これは完全に正常です。通常、夏の間
にソーラーパネルの温度は 60℃近くに達するため、射される日光のレベルが高いにもかかわらず、公称電力より発電
量が 13% ぐらい減少します。
3. 設置角度。良好な日光条件では、より多くの発電量を作り出すため、日光を製品の表面に対して 90°で垂直に当たり
続ける必要があります。90°の角度が± 10°ぐらいの誤差があっても、発電量への影響はわずかになります。
4. パネルの影。使用中にソーラーパネルの表面に影がかからないようにしてください。影、異物、ガラスが原因で生じ
る影は、発電量を大幅に減少させます。
機能不良のパネルによるパフォーマンスの問題:上記の問題に対処した後も、パネルがまだ電力を生成しない場合、ま
たはパネルの出力が予想される公称電力値より大幅に下回っている場合は、不具合が発生している可能性があります。
サポートが必要な場合は、EcoFlow アフターサポートへお問い合わせください。
EcoFlow 110W ソーラーパネルを他のサイズのソーラーパネルと直列で接続できますか?
他のサイズのソーラーパネルと直列で接続できますが、お勧めしません。ソーラーパネルの電圧が同じで定格電流が異
なる場合、電流値が定格電流が弱い方に制限され、ソーラーパネルの発電量は不十分になってしまいます。そのため、
直列で接続する時、発電量を低下させないように、同じ仕様のソーラーパネルをご利用ください。
EcoFlow 110W ソーラーパネルを並列で接続できますか?
並列で接続できますが、お勧めしません。EcoFlow 110W ソーラーパネルは並列で接続可能ですが、出力の電流値が高す
ぎてポータブル電源の対応可能の入力電流範囲をオーバーする可能性があります。並列接続は、電流を倍にすることで発
電量を増やさせます。しかし、並列でソーラーパネルを接続すると、ポータブル電源の最大入力電流の制限によって総発
電量が制限されます。そのため、入力電流制限が高いポータブル電源をご利用されない限り、複数の EcoFlow 110W ソー
ラーパネルを並列で接続することはお勧めしません。
EcoFlow 110W ソーラーパネルの発電量は通常の条件下でどれくらいありますか?
ソーラーパネルの発電量は天候条件によって影響されます。通常、雲のない晴れた日に、90 °の角度で日光が当たってい
る時、88W ~ 90W ぐらいの発電量が得られます。
EcoFlow 110W ソーラーパネルの動作温度、保管、および使用について知っておくこと?
ソーラーパネルの動作温度は -20℃ ~ 85℃です。使用しない時、製品は最初の形状に折りたたみ、十分に保護されるよう
に保護ケースに格納してください。製品の耐用年数を延ばすために、製品に強い衝撃や振動を与えないでください。また、
内蔵セルの破損を防ぐために、本製品を落としたり、穴を開けたり、曲げたり、上に座ったりしないでください。製品が
上記の行為による破損される場合は、無償保証の対象外になります。
EcoFlow 110W ソーラーパネルを他社のポータブル電源で使用できますか?
はい。ただし、特定のタイプのみです。正常に動作させるには、ご利用のポータブル電源が「MC4」規格と互換性があ
る必要があります。また、他社のポータブル電源は、EcoFlow のポータブル電源と同じレベルの互換性を提供できない、
公称電力が低い、同じレベルのパフォーマンスを提供できないといった可能性があります。
温度係数の仕様
出力温度係数 -(0.39±0.02)%/k
電圧温度係数 -(0.33±0.03)%/k
電流温度係数 +(0.06±0.015)%/k
製品仕様
110W ソーラーパネル
全般
定格出力 : 110 W(+/-5 W)*
開放電圧 : 21.8 V
動作電圧 : 18.4 V
短絡電流 : 6.5 A
動作電流 : 6.0 A
変換効率 : 22.4 %-22.8 %
セル種類 : 単結晶シリコン
出力コネクタ仕様 : MC4
総重量 : 6 kg
正味重量 : 4 kg
展開寸法 : 42.0*178.5*2.5 cm
収納寸法 : 42.0*48.0*2.5 cm
保証期間 : 12 か月
* 標準テスト条件 : 1000W/ ㎡ 、AM1.5、25℃
太阳能充电板
联系我们:
www.ecoflow.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

EcoFlow 110W Solar Panel ユーザーガイド

タイプ
ユーザーガイド

他の言語で