Dell PowerVault MD3200 ユーザーマニュアル

タイプ
ユーザーマニュアル

このマニュアルも適しています

Dell PowerVault MD3200 and
MD3220 Storage Arrays
Getting Started
With Your System
系统使用入门
Memulai Pengaktifan dengan Sistem Anda
はじめに
시스템 시작 안내서
Dell PowerVault MD3200 and
MD3220 Storage Arrays
Getting Started
With Your System
Regulatory Model Series E03J and E04J
Notes, Cautions, and Warnings
NOTE:
A NOTE indicates important information that helps you make better use
of your computer.
CAUTION:
A CAUTION indicates potential damage to hardware or loss of data
if instructions are not followed.
WARNING:
A WARNING indicates a potential for property damage,
personal injury, or death.
____________________
Information in this publication is subject to change without notice.
© 2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerVault™ are trademarks of Dell Inc.
Microsoft
®
and Windows Server
®
are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries. Red Hat
®
and Red Hat Enterprise Linux
®
are
registered trademarks of Red Hat, Inc. in the United States and other countries. SUSE
®
is a registered
trademark of Novell, Inc. in the United States and other countries. VMware
®
is a registered trademark
of VMware, Inc. in the United States and/or other jurisdictions.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Model Series E03J and E04J
2011 - 08 P/N J7RX7 Rev. A02
Getting Started With Your System
3
Before You Begin
NOTE:
Throughout the document, Dell PowerVault MD3200 series storage array
refers to both Dell PowerVault MD3200 and Dell PowerVault MD3220. Dell
PowerVault MD1200 series expansion enclosure refers to both Dell PowerVault
MD1200 and Dell PowerVault MD1220.
Before setting up your Dell PowerVault MD3200 series storage array, you must
consider certain best practices to ensure that your storage array operates at
maximum efficiency and offers full redundancy (if required).
Throughout the network, always use a Category 5e (or higher)
Ethernet cable.
Before connecting any cables between the host server and storage array,
physically label each port and connector.
Always follow proper power-up and power-down procedures when cycling
power across the network. You must also ensure that critical network
components are on separate power circuits.
Other Documentation and Media You May Need
WARNING:
See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document or
as a separate document.
NOTE:
All PowerVault MD3200 series documents are available at
support.dell.com/manuals.
The rack documentation included with your rack solution describes how to
install your system into a rack.
The
Owner’s Manual
provides information about system features and
describes how to troubleshoot the system and install or replace system
components.
The
Deployment Guide
provides information about installing and
configuring the software and hardware.
The
CLI Guide
provides information about using the command line
interface (CLI) to configure and manage your storage array.
4
Getting Started With Your System
•The
SMI-S Programmer’s Guide
provides information about using the
SMI-S provider and SMI-S programming.
Any media that ships with your system that provides documentation and
tools for configuring and managing your system, including those
pertaining to the operating system, system management software,
system updates, and system components that you purchased
with your system.
NOTE:
Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
Supported Operating Systems
Microsoft Windows Server
Red Hat Enterprise Linux
SUSE Linux Enterprise Server
VMware
NOTE:
For the latest information on all the supported operating system versions,
see the Support Matrix at support.dell.com/manuals.
Getting Started With Your System
5
Common Configurations
Cabling Your Direct-Attached Hosts
Server 1 Server 2
Corporate, public,
or private network
Server 3 Server 4
PowerVault MD3200
series storage array
6
Getting Started With Your System
Installation and Configuration
WARNING:
Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item with the packing list that shipped
with your system.
Installing the Rails and System in a Rack
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
NOTE:
To balance the weight load, it is recommended that you install the
PowerVault MD3200 series storage array at the bottom of the rack and the
PowerVault MD1200 series expansion enclosures above it.
Getting Started With Your System
7
Connecting the Power Cable(s)
Ensure that the power switch is in the OFF position before connecting the
power cables. Connect the system’s power cable(s) to the system.
Securing the Power Cable(s)
Secure the cable(s) firmly to the bracket using the provided strap.
Plug the other end of the power cables into a grounded electrical outlet or
a separate power source such as an uninterrupted power supply (UPS) or
a power distribution unit (PDU). Each power supply must be connected
to a separate power circuit.
8
Getting Started With Your System
Cabling Your Expansion Enclosure
Turning On the Enclosure
Turn on the components in the following order:
1
PowerVault MD1200 series expansion enclosures (if used)
NOTE:
Before turning on the storage array, ensure that the expansion
enclosure status LED is blue.
PowerVault MD3200
series storage array
PowerVault MD1200
series expansion
enclosure 1 (optional)
PowerVault MD1200
series expansion
enclosure 2 (optional)
Getting Started With Your System
9
2
PowerVault MD3200 series
storage array
NOTE:
Before turning on the host server(s), ensure that the storage array
status LED is blue.
3
Host server(s)
Installing the Bezel
Install the bezel (optional).
Installing the MD Storage Software
NOTE:
For detailed instructions about installing the MD storage software, setting
up the enclosure, and the post-installation tasks, see the Deployment Guide.
The MD Storage Manager application configures, manages, and monitors the
storage array. To install the MD storage software:
1
Insert the MD series resource media.
Depending on your operating system, the installer may launch
automatically. If the installer does not launch automatically, navigate to
the root directory of the installation media (or downloaded installer
image) and run the
md_launcher.exe
file. For Linux-based systems,
navigate to the root of the resource media and run the
autorun
file.
NOTE:
By default, the Red Hat Enterprise Linux operating system mounts the
resource media with the -noexec mount option which does not allow you to
run executable files. To change this setting, see the Readme file in the root
directory of the installation media.
10
Getting Started With Your System
2
Select
Install MD Storage Software
.
3
Read and accept the license agreement.
4
Select one of the following installation options from the
Install Set
drop-down menu:
Full (recommended)
—Installs the MD Storage Manager (client)
software, host-based storage agent, multipath driver, and hardware
providers.
Host Only
—Installs the host-based storage agent and multipath
drivers.
Management
—Installs the management software and hardware
providers.
Custom
—Allows you to select specific components.
5
Select the MD storage array model(s) you are setting up to serve as data
storage for this host server.
6
Choose whether to start the event monitor service automatically when the
host server reboots or manually
NOTE:
This option is applicable only to Windows client software installation.
7
Confirm the installation location and click
Install
.
8
If prompted, reboot the host server once the installation completes.
9
Start the
MD Storage Manager
and discover the array(s).
10
If applicable, activate any premium features purchased with your storage
array. If you purchased premium features, see the printed activation card
shipped with your storage array.
NOTE:
The MD Storage Manager installer automatically installs the required
drivers, firmware, and operating system patches/hotfixes to operate your storage
array. These drivers and firmware are also available at support.dell.com. In
addition, see the Support Matrix at support.dell.com/manuals for any additional
settings and/or software required for your specific storage array.
Getting Started With Your System
11
Locating Your Service Tag
Your system is identified by a unique Express Service Code and Service Tag
number. The Express Service Code and Service Tag are found on the front
of the system and at the back of the system next to the RAID controller
modules. This information is used by Dell to route support calls to the
appropriate personnel.
NOM Information (Mexico Only)
The following information is provided on the device described
in this document in compliance with the requirements of the
official Mexican standards (NOM):
Importer:
Model number: E03J and E04J
Supply voltage: 100–240 V CA
Frequency: 50/60 Hz
Current consumption: 8.6 A
12
Getting Started With Your System
Technical Specifications
Drives
PowerVault MD3200 Up to twelve 3.5-inch SAS hot-swappable
hard drives (3.0 Gbps and 6.0 Gbps)
PowerVault MD3220 Up to twenty four 2.5-inch SAS hot-swappable
hard drives (3.0 Gbps and 6.0 Gbps)
RAID Controller Modules
RAID controller modules
One or two hot-swappable modules with
temperature sensors
2 GB of cache per controller
Back-Panel Connectors (Per RAID Controller Module)
SAS connectors
Four SAS IN ports to connect hosts
One SAS OUT port for expansion to an additional
PowerVault MD1200 series enclosure
NOTE:
SAS connectors are SFF-8088 compliant.
Serial connector One 6-pin mini-DIN connector
NOTE:
For technical support use only.
Management Ethernet
connector
One 100/1000 Base-T port Ethernet for out-of-band
management of the enclosure
NOTE:
The default management port IP addresses for
the primary and secondary RAID controller modules
are 192.168.128.101 and 192.168.128.102, respectively.
By default, the management ports are set to Dynamic
Host Configuration Protocol (DHCP). If the controller
is unable to get an IP address configuration from
a DHCP server within a specified time out period
(approximately 3 minutes), it defaults back to
static IP addressing. For more information,
see the Deployment Guide.
Getting Started With Your System
13
Expansion
PowerVault MD1200 series Supports a maximum of 192 hard drives with any
combination of PowerVault MD1200 or PowerVault
MD1220 expansion enclosures. Support for 192 hard
drives is a Premium Feature and requires activation.
The maximum number of hard drives supported
without using the Premium Feature is 120.
Redundant path connectivity provides redundant
data paths to each hard drive.
Backplane Board
Connectors
12 or 24 SAS hard-drive connectors
Two power supply/cooling fan module connectors
Two sets of RAID controller module connectors
One control panel connector for front LEDs and
system identification button
Sensors Two temperature sensors
LED Indicators
Front panel
One two-color LED indicator for system status
Two single-color LED indicators for power and
enclosure mode
NOTE:
The enclosure mode LED is not applicable to
the PowerVault MD3200 series storage array.
Hard-drive carrier
One single-color activity LED
One two-color LED status indicator per drive
Power supply/cooling fan Three LED status indicators for power supply status,
power supply/fan fault, and AC status
14
Getting Started With Your System
RAID controller module Six single-color LEDs:
One battery fault
One cache active
One controller fault
One controller power
One system identification
One management Ethernet activity
Six two-color LEDs:
Four SAS IN link or fault
One SAS OUT link or fault
One management Ethernet link speed
Switch
System identification button Located on the front control panel. This button is
used to locate a system within a rack.
Enclosure mode switch Located on the front of the system. This switch is
not applicable to the PowerVault MD3200 series
storage array.
Password reset switch Located on the back-panel of the RAID controller
module. This switch is used to reset the storage array
password.
Power Supplies
AC power supply (per power supply)
Wa tt ag e
600 W
Voltage
100–240 VAC (8.6 A–4.3 A)
Heat dissipation
100 W
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach a maximum of 55 A per power supply for
10 ms or less.
LED Indicators (continued)
Getting Started With Your System
15
Available Hard Drive Power (Per Slot)
PowerVault MD3200 25 W
PowerVault MD3220 12 W
RAID Controller Module Power (Per Slot)
Maximum power consumption 100 W
Physical
PowerVault MD3200
Height
8.68 cm (3.41 inches)
Width
44.63 cm (17.57 inches)
Depth
60.20 cm (23.70 inches)
Weight (maximum
configuration)
29.30 kg (64.6 lb)
Weight (empty)
8.84 kg (19.5 lb)
PowerVault MD3220
Height
8.68 cm (3.41 inches)
Width
44.63 cm (17.57 inches)
Depth
54.90 cm (21.61 inches)
Weight (maximum
configuration)
24.22 kg (53.4 lb)
Weight (empty)
8.61 kg (19 lb)
16
Getting Started With Your System
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Tem perat ure
Operating
10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20°C per hour.
Relative humidity
Operating
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.25 G at 3–200 Hz for 15 min
Storage
0.5 G at 3–200 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse on
each side of the system) of 31 G for 2.6 ms in the
operational orientation
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985
Dell PowerVault MD3200
MD3220 存储阵列
系统使用入门
管制型号系列 E03J E04J
注、小心和警告
注:
“注”表示可以帮助您更好地使用计算机的重要信息。
小心:
“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据丢失。
警告:
“警告”表示可能会导致财产损失、人身伤害甚至死亡。
____________________
本出版物中的信息如有更改,恕不另行通知。
© 2011 Dell Inc. 版权所有,翻印必究。
未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。
本文中使用的商标Dell™
DELL 徽标、PowerVault™
Dell Inc. 的商标。Microsoft
®
Windows Server
®
Microsoft Corporation 在美国和 / 或其他国家 / 地区的商标或注册商标。
Red Hat
®
Red Hat Enterprise Linux
®
Red Hat, Inc. 在美国和其他国家 / 地区的注册商标。
SUSE
®
Novell, Inc. 在美国和其他国家或地区的注册商标。VMware
®
VMware, Inc. 在美
国和 / 或其他管辖区域的注册商标。
本出版物中述及的其它商标和商品名称是指拥有相应商标和商品名称的公司或其产品。
Dell Inc. 对不属于自己的商标和商品名称不拥有任何所有权。
管制型号系列 E03J E04J
2011 - 08 P/N 7JRX7 Rev. A02
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Dell PowerVault MD3200 ユーザーマニュアル

タイプ
ユーザーマニュアル
このマニュアルも適しています