Livox T1 HAP ユーザーガイド

タイプ
ユーザーガイド
LIVOX HAP
HAP (T1)
Quick Start Guide
快速入门指南
クイックスタートガイド
Betriebsanleitung (Kurzfassung)
v1.0
1
Contents
EN Quick Start Guide 2
CHS 快速入门指南8
DE Kurzanleitung 25
KR 19
JP クイックスタートガイド13
Compliance Information 31
LIVOX HAP Quick Start Guide
2
DISCLAIMER
This product is NOT a toy and is not suitable for children under the age of 16. Adults should keep the product out of the reach of
children and exercise caution when operating this product in the presence of children.
This product incorporates various advanced technologies. However, inappropriate use of the product could result in personal injury or
property damage. Read the materials associated with the product before using for the rst time. These documents are included in the
product package or are available on the LIVOX™ Technology Company Limited (“Livox”) website (www.livoxtech.com).
The information in this document aects your safety and your legal rights and responsibilities. Read this entire document carefully to
ensure proper conguration before use. Failure to read and follow the instructions and warnings in this document may result in serious
injury to yourself or others, damage to or loss of your Livox product, or damage to other objects in the vicinity.
By using this product, you hereby signify that you have read this disclaimer carefully and that you understand and agree to abide
by the terms and conditions herein. EXCEPT AS EXPRESSLY PROVIDED IN LIVOX AFTER-SALES SERVICE POLICIES AVAILABLE
AT www.livoxtech.com, THE PRODUCT AND ALL MATERIALS, AND CONTENT AVAILABLE THROUGH THE PRODUCT ARE
PROVIDED “AS IS” AND ON AN “AS AVAILABLE” BASIS, WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS
OR IMPLIED. LIVOX DISCLAIMS ALL WARRANTIES OF ANY KIND, EXCEPT AS EXPRESSLY PROVIDED IN LIVOX AFTERSALES
SERVICE POLICIES, WHETHER EXPRESS OR IMPLIED, RELATING TO THE PRODUCT, PRODUCT ACCESSORIES, AND ALL
MATERIALS, INCLUDING: (A) ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE,
QUIET ENJOYMENT, OR NONINFRINGEMENT; AND (B) ANY WARRANTY ARISING OUT OF COURSE OF DEALING, USAGE,
OR TRADE. LIVOX DOES NOT WARRANT, EXCEPT AS EXPRESSLY PROVIDED IN LIVOX WARRANTY, THAT THE PRODUCT,
PRODUCT ACCESSORIES, OR ANY PORTION OF THE PRODUCT, OR ANY MATERIALS, WILL BE UNINTERRUPTED, SECURE, OR
FREE OF ERRORS, VIRUSES, OR OTHER HARMFUL COMPONENTS, AND DOES NOT WARRANT THAT ANY OF THOSE ISSUES
WILL BE CORRECTED.
NO ADVICE OR INFORMATION, WHETHER ORAL OR WRITTEN, OBTAINED BY YOU FROM THE PRODUCT, PRODUCT
ACCESSORIES, OR ANY MATERIALS WILL CREATE ANY WARRANTY REGARDING LIVOX OR THE PRODUCT THAT IS NOT
EXPRESSLY STATED IN THESE TERMS.
YOU ASSUME ALL RISKS FOR ANY DAMAGE THAT MAY RESULT FROM YOUR USE OF OR ACCESS TO THE PRODUCT,
PRODUCT ACCESSORIES, AND ANY MATERIALS. YOU UNDERSTAND AND AGREE THAT YOU USE THE PRODUCT AT YOUR
OWN DISCRETION AND RISK, AND THAT YOU ARE SOLELY RESPONSIBLE FOR ANY PERSONAL INJURY, DEATH, DAMAGE TO
YOUR PROPERTY (INCLUDING YOUR COMPUTER SYSTEM OR MOBILE DEVICE OR LIVOX HARDWARE USED IN CONNECTION
WITH THE PRODUCT) OR THIRD PARTY PROPERTY, OR THE LOSS OF DATA THAT RESULTS FROM YOUR USE OF OR INABILITY
TO USE THE PRODUCT. SOME JURISDICTIONS MAY PROHIBIT A DISCLAIMER OF WARRANTIES AND YOU MAY HAVE OTHER
RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION.
Livox accepts no liability for damage, injury, or any legal responsibility incurred directly or indirectly from the use of this product. The
user shall observe safe and lawful practices including, but not limited to, those set forth in this quick start guide. You shall be solely
responsible for all your behavior when using this product.
WARNINGS
1. Be careful when using Livox HAP™ in conditions with low visibility such as foggy or stormy weather. In such conditions, the
detection range may be reduced. For detection range in conditions with high visibility, refer to the Specications section.
2. When mounting Livox HAP, allow a space of at least 10 mm around Livox HAP to avoid poor air ow aecting heat dissipation, and
make sure the waterproof breather valve is not blocked. It is normal for the temperature of Livox HAP to increase during use.
3. DO NOT touch the optical window of Livox HAP. Dust and stains on the optical window can negatively aect the performance.
Use compressed air, isopropyl alcohol, or a lens cloth to clean the optical window correctly. Refer to Livox HAP User Manual for
more information on how to clean the optical window.
4. When customizing Livox HAP power cables, make sure the current-carrying capacity of the cable can support the power
LIVOX HAP Quick Start Guide
3
1. Optical Window
2. Locating Hole 1
3. M6 Mounting Hole (φ6.5) ×4
4. Automotive Ethernet Connector (100BASE-T1)
5. Power Connector
6. M3 Mounting Hole ×4
7. Locating Hole 2
8. Waterproof Breather Valve
HAP (T1)
8
7
1
2
3
4
5
6
requirement of Livox HAP. Otherwise, the product may become a re hazard or be damaged permanently.
5. In order to avoid electric shocks or radiation exposure, DO NOT disassemble Livox HAP. If an accessory or product part needs to
be replaced, contact Livox for support.
6. Livox HAP is classied as a Class 1 Laser Product (IEC/EN 60825-1: 2014) and is safe under all normal conditions of use.
7. Liquid damage is not covered under warranty.
8. DO NOT drop Livox HAP.
9. The Livox HAP Quick Start Guide contains important information. Make sure to read before rst use and keep for reference.
Introduction
As the next-generation product of Livox Horizon, Livox HAP is a high-performance LiDAR sensor with a compact design and superior
precision. It can be used for multiple applications including autonomous driving, robotic navigation, dynamic path planning, and high-
precision mapping. Compared to Livox Horizon, Livox HAP features a FOV of 120° (horizontal) and 25° (vertical), a longer detection
range of 150 m (at 10% reectivity, 100 klux), and a higher point rate of 452K points/s. Users can check real-time point clouds using
Livox Viewer 2, and a software development kit (Livox SDK) is provided to help you develop customizable applications using 3D data
acquired from point clouds. Livox HAP has two models which are HAP (T1) and HAP (TX). This document is intended for HAP (T1).
Installation and Connection
Eective FOV Range
HAP (T1) has a FOV of 120° (horizontal) × 25° (vertical) as shown below. When mounting HAP (T1), make sure that the FOV is not
blocked by any objects. Visit www.livoxtech.com/hap to download the 3D models of HAP (T1) and its FOV.
Vertical HorizontalHorizontal
120°
25°
LIVOX HAP Quick Start Guide
4
Note that the eective detecting distance of HAP (T1) varies based on where the object is within the FOV. The closer to the edge of
the FOV, the shorter the eective detecting distance is. The closer to the center of the FOV, the further the eective detecting distance.
Refer to the diagrams below.
Always pay attention to the eective detecting range when in use.
10% Reectivity
Unit: m
Horizontal
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60°
60°
200
175
150
125
100
75
50
45°
30°
10° 15°
-15°
Mounting the HAP (T1)
Refer to the dimensions and the mounting holes in the diagrams below to mount or embed HAP (T1) appropriately. Note that the
corresponding screws should be purchased in advance.
0.65
92.65
3±0.05
62
1
54
2
94.6
48.5
121.6
91.6
47
131.6
105
65
3±0.05 1
4-M3 5
4- 6.5±0.1
Unit: mm
Vertical
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60° 60°
200
175
150
125
100
75
50
45°
30°
10°
15°
-15°
LIVOX HAP Quick Start Guide
5
Connecting the Cables
The power cable and the automotive Ethernet cable are both optional accessories for HAP (T1). They need to be purchased
separately.
Refer to diagrams below for the connector definitions for the cables. Make sure to connect the cables correctly based on the
connector denitions.
Power Connector and Automotive Ethernet Connector of HAP (T1)
See below for more information on the power connector and the automotive
Ethernet connector of HAP (T1).
1
2
3
4
5
6
78
Power Cable
Connect A to the power connector of HAP (T1), and the connector type for A is TE 1-967616-1. Connect B to an external DC power
supply, and the connector type for B is XT30.
A
A
B
B
MDI+
MDI-
Automotive Ethernet Cable
Connect A to the automotive Ethernet connector of HAP (T1), and the connector type for A is TE 1802105-1. Connect B to the
automotive Ethernet connector of an automotive Ethernet converter, and the connector type for B is MOLEX 347910040.
Pin Signal Type Description Function
1 Power+ Power DC VCC Power Cable
(connects to DC power supply)
4 Ground Power Ground
7 MDI+ Inupt/Output 100Base-T1 Automotive Ethernet Cable
(connects to automotive Ethernet devices)
8MDI- Inupt/Output 100Base-T1
2N/A N/A N/A
Function Cable
(Not in use. DO NOT connect with other power cable or
signal cable to avoid short circuit.)
3N/A N/A N/A
5 N/A N/A N/A
6N/A N/A N/A
Connecting the HAP (T1)
All HAP (T1) are set to static IP address mode by default with an IP address of 192.168.1.100. The default subnet masks of HAP (T1)
are 255.255.255.0 and their default gateways are 192.168.1.1. To connect with a computer for testing and debugging, users need to
purchase a converter that can convert from 100BASE-T1 automotive Ethernet to standard 100BASE-TX Ethernet, and the automotive
Ethernet module of the converter needs to work in Master mode when connected to HAP (T1). Make sure the converter you purchase
meets the specied requirements.
1. Before connecting, set the IP address of the computer to static IP address mode. Set the IP address of the computer to the
A
A
B
BVCCGround
LIVOX HAP Quick Start Guide
6
a. Connect one end of the automotive Ethernet cable to the automotive Ethernet connector of HAP (T1), and connect the other
end to the automotive Ethernet connector of the converter.
b. Connect one end of the power cable to the power connector of HAP (T1), and connect the other end to an external power
supply.
c. Connect the converter to an external power supply.
d. Connect the converter to the computer using an Ethernet cable.
3. Set the automotive Ethernet module of the converter to Master mode. For the specific setup method, refer to the usage
instructions for the purchased converter.
Refer to the Livox HAP User Manual on how to set the IP address of the computer.
When multiple HAP (T1) LiDAR sensors are connected to one computer in static IP address mode, make sure all sensors
connected have dierent static IP addresses. Refer to Livox HAP User Manual for more information on how to set the IP
address for each LiDAR sensor.
The working voltage of HAP (T1) is 9 to 18 V DC. Therefore, when connecting the Livox HAP directly to an external power
source, make sure the voltage range of the external power source is within the allowable range. Make sure the positive and
negative ends of the power cable are connected correctly.
Downloading and Using Livox Viewer 2
Visit http://www.livoxtech.com and download the latest Livox Viewer 2 to check the point cloud data. Livox Viewer 2 supports
WINDOWS® 10 (64 bit) and UBUNTUTM 18.04 (64 bit).
1. Download the le named “Livox Viewer 2”.
2. Unzip the Livox Viewer 2 le and click to open the .exe le named “Livox Viewer 2”. For Ubuntu users, unzip the Livox Viewer 2 le
and click to open the “./livox_viewer_2.sh” le under the root directory.
3. If a system window with network authorization pops up when opening Livox Viewer 2, allow Livox Viewer 2 to access network.
4. The device manager window is on the left side of Livox Viewer 2 and the main interface is on the right side. Click to display
or hide the device manager window. In this device manager window, users can check all Livox LiDAR sensors in the local area
network (LAN).
5. Click “LiDAR” on the top of the device manager window.
6. Select the Livox HAP you want to check and click to connect. Alternatively, select the Livox HAP you want to check, right click,
and click “Connect”.
7. After connecting, click or press the space key on the keyboard to view the point cloud data.
HAP (T1) Converter Computer
external power supply
external power supply
Connects to the
automotive Ethernet
connector of the
converter
Connects to a
computer using an
Ethernet cable
same network subnet as the IP address of HAP (T1) (example: 192.168.1.50), and set the subnet mask of the computer to
255.255.255.0.
2. Connect HAP (T1) as shown below.
LIVOX HAP Quick Start Guide
7
For Windows users, Livox Viewer 2 may fail to detect LiDAR sensors if Windows Firewall is turned on. In this situation, go
to the Control Panel to turn o Windows Firewall and restart Livox Viewer 2.
Download and read the Livox Viewer 2 User Manual for more information on how to use Livox Viewer 2.
Low Temperature Start-Up
The working temperature of HAP (T1) is from -40° to 85° C (-40° to 185° F). When the environment temperature is below C
(-32° F), HAP (T1) may enter self-heating mode when connecting to a power supply. The lower the temperature, the greater the
self-heating power. The power in self-heating mode may reach a maximum of 40 W. Therefore, make sure the external power
source is appropriate, especially in a low-temperature environment.
Specications
Model HAP (T1)
Laser Wavelength 905 nm
Laser Safety Class 1 (IEC 60825-1:2014) (safe for eyes)
Detection Range (@100 klx) 150 m @ 10% reectivity
FOV 120° (horizontal) × 25° (vertical)
Distance Random Error (1σ)< 2 cm @ 20 m (80% reectivity)
Distance System Error < ±3 cm @ 20 m
Angular Random Error (1σ) < 0.1°
Beam Divergence 0.03° (horizontal) × 0.28° (vertical)
Point Rate 452,000 points/s
Data Port 100BASE-T1 Automotive Ethernet
Data Synchronization gPTP
False Alarm Ratio
(@100 klx)
0.01%
Operation Temperature
Range
-40℃ to 85℃ (-40° to 185°F)
Storage Temperature Range -40℃ to 95℃ (-40° to 203°F)
IP Rating IP67
Power Rated power 12 W
Starting power 26 W
Low temperature heating power 40 W
Power Supply Voltage
Range
9-18 V DC
Noise < 45 dB(A) (40 cm omnidirectional)
Dimensions 105 × 131.6 × 65 mm
Weight Approx. 1120 g
IMU Not supported.
The divergence of the embedded laser is approximately 25.2°
(horizontal) × (vertical), which was measured at full width at half
maximum. The maximum power of the embedded laser may exceed
65 W. In order to avoid being injured by the laser, DO NOT disassemble
HAP (T1).
HAP (T1) cannot precisely detect objects which are less than 0.5 m
away.
Tested in an environment at a temperature of 25° C (77° F). The actual
environment may dier from the testing environment. The gure listed is
for reference only. The point cloud may distort to a varying extent when
the target object is within the range of 0.5 to 2 m.
The false alarm ratio of the noise created by the stray light in a test
environment of 100 klx at a temperature of 25° C (77° F).
HAP (T1) can achieve an IP rating of IP67 when connected with the
power and automotive Ethernet cables. If not connected to the two
cables, the IP rating for HAP (T1) is IP54.
In low-temperature environments, HAP (T1) will rst enter self-heating
mode, and its power may reach a maximum amount of 40 W. Make
sure the power supply is suitable based on the peak power value of the
Livox HAP. Refer to HAP (T1) User Manual for more information.
Make sure the output voltage of the power supply is within this range at
all times.
LIVOX HAP 快速入门指南
8
免责声明
本产品不适合未满 16 岁的人士使用。请勿让儿童接触本产品,在有儿童出现的场景操作时请务必特别小心注意。
使用前请仔细阅读并遵循本产品说明书指导,同时遵守任何相关的国家和国际相关的安全条例。本产品是一款激光探测测距仪,在
电源正常工作及各部件未损坏的情况下将提供三维激光扫描功能。访问 www.livoxtech.com 获取完整的《Livox HAP 用户手册》、
最新说明和警告。香港览沃科技有限公司(以下简称“LivoxTM”)保留更新所有文档的权利。
请务必在使用产品之前仔细阅读本文档和《用户手册》,了解您的合法权益、责任和安全说明;否则,可能带来财产损失、安全事
故和人身安全隐患。一旦使用本产品,即视为您已理解、认可和接受本文档全部条款和内容。使用者承诺对自己的行为及因此而产
生的所有后果负责。使用者承诺仅出于正当目的使用本产品,并且同意本文档全部条款和内容及 Livox 可能制定的任何相关政策或
者准则。
Livox 不承担因用户未按本文档、《用户手册》使用产品所引发的一切损失。 在遵从法律法规的情况下,Livox 享有对本文档的最终
解释权。Livox 有权在不事先通知的情况下,对本条款进行更新,改版或终止。
1. 在空气能见度较差的情况下(例如雾霾、暴雨天气),Livox HAP™ 的有效检测范围将会减小,使用时请格外小心。空气能见度
较好情况下,Livox HAP 的有效检测范围请查看参数列表。
2. 安装时,建议在 Livox HAP 壳体周围留有 10mm 以上的空间用于通风散热,并确保防水透气阀不被堵塞。工作时,产品温度将
会有所上升,此为正常现象。
3. 切勿用手触摸 Livox HAP 窗口。 Livox HAP 窗口上有污点或灰尘等杂质,请使用压缩空气除尘罐,酒精以及无尘布进行清洁(具
体清洁方式,请查看《Livox HAP 用户手册》),以免污点灰尘等影响产品性能。
4. 如自行定制电源线,请确认所使用的线材负载能力达到产品功耗需求,否则可能导致产品损坏,甚至引发火灾。
5. 为减少触电危险以及防止可能存在的光辐射危险,请勿私自拆开或改装本产品。本产品不包含用户可维修零件,需售后服务请
联系 Livox
6. Livox HAP 满足 Class 1 激光产品安全要求(IEC/EN 60825-1:2014),可于正常情况下安全使用。
7. 因液体造成的损坏不在保修范围内。
8. 切勿摔落 Livox HAP
9. 包装或说明书中含有重要信息,应保留。
简介
Livox HAP Livox Horizon 的升级产品,继承了高可靠性、结构设计紧凑以及高精度特性,可广泛应用于包括无人驾驶环境感知、
机器人导航、动态路径规划、高精度测绘等众多领域。相较于 Livox HorizonLivox HAP 在视场角、量程和点云输出上均有显著提升,
其中视场角达到水平 120°,竖直 25°,量程达到 150m10% 反射率,100 klx),点云输出提升到 452,000 / 秒。用户可通
Livox Viewer 2 软件实时获取三维图像,更能基于 Livox SDK 进行开发,轻松获取 3D 点云数据,满足个性化的应用需求。Livox
HAP 分为 HAP (T1) HAP (TX) 两种型号。本文档适用于 HAP (T1)
1. 窗口
2. 定位孔 1
3. M6 螺钉安装通孔(φ6.5)×4
4. 车载以太网接口(100BASE-T1
5. 电源接口
6. M3 安装孔 ×4
7. 定位孔 2
8. 防水透气阀
HAP (T1)
8
7
1
2
3
4
5
6
LIVOX HAP 快速入门指南
9
安装连线
有效视场角(FOV)范围
HAP (T1) FOV 为水平 120°,竖直 25°,如下图所示。安装时请注意 FOV 的有效范围,避免遮挡 FOV 区域。可访问 www.
livoxtech.com/hap 下载 HAP (T1) 与其 FOV 3D 模型。
竖直方向 水平方向
水平方向
120°
25°
请注意,HAP (T1) 的有效量程在不同的 FOV 区域内有所区别,越靠近 FOV 边缘有效量程越短,越靠近 FOV 中间位置,有效量程
越接近最大值,可参考下图:
使用时请格外注意有效量程的范围。
10% 反射率
单位:m
竖直方向
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60° 60°
200
175
150
125
100
75
50
45°
30°
10°
15°
-15°
水平方向
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60°
60°
200
175
150
125
100
75
50
45°
30°
10° 15°
-15°
LIVOX HAP 快速入门指南
10
安装 HAP (T1)
请根据如下图所示的 HAP (T1) 机身尺寸及安装孔位尺寸,自购对应规格螺丝,将其安装至合适位置。
连线
电源线和车载以太网线均为 HAP (T1) 的选配件,需额外购买。
线序如下,请确保按照线序(或正负极)正确进行连接。
0.65
92.65
3±0.05
62
1
54
2
94.6
48.5
121.6
91.6
47
131.6
105
65
3±0.05 1
4-M3 5
4- 6.5±0.1
电源线
A端接 HAP (T1) 的电源接口,连接器型号为 TE 1-967616-1B端外接直流稳压电源,连接器型号为 XT30
车载以太网线
A端接 HAP (T1) 的车载以太网接口,连接器型号为 TE 1802105-1B端连接至转换器的车载以太网接口,连接器型号为
MOLEX 347910040
HAP(T1)电源接口和车载以太网接口
HAP (T1) 的电源接口和车载以太网接口的线序定义如下:
1
2
3
4
5
6
78
单位: mm
A
A
B
BVCCGround
A
A
B
B
MDI+
MDI-
LIVOX HAP 快速入门指南
11
电源接口和车载以太网接口管脚 信号 属性 描述 功能
1 Power+ Power DC VCC 电源线
(接直流电源)
4 Ground Power Ground
7 MDI+ Inupt/Output 100Base-T1 车载以太网线
(接车载以太网设备)
8 MDI- Inupt/Output 100Base-T1
2 N/A N/A N/A
功能线
(不适用,可不接;勿与其他电源线或信号线相
接导致短路)
3 N/A N/A N/A
5 N/A N/A N/A
6 N/A N/A N/A
连接 HAP (T1)
HAP (T1) 出厂默认为静态 IP,地址为 192.168.1.100,子网掩码为 255.255.255.0,默认网关为 192.168.1.1。若需连接电脑进行
调试,需自行购买 100BASE-T1 车载以太网转 100BASE-TX 标准以太网的转换器,且连接后转换器的车载以太网模块需工作在主
机(Master)模式。请确保所购转换器符合所述要求。
1. 连接前,将电脑的 IP 设置静态 IP,并 将 IP 地址设置为与 HAP (T1) IP 地址同一个网段,192.168.1.50子网掩码设置为
255.255.255.0
2. 电脑静态 IP 地址设置完成后,请按照图示连接。
a. 将车载以太网线一端连接至 HAP (T1) 的车载以太网接口,另一端连接至转换器的车载以太网接口。
b. 将电源线一端连接至 HAP (T1) 的电源接口,另一端连接至外部电源。
c. 连接转换器至外部电源。
d. 使用以太网线,将转换器连接至个人电脑。
3. 将转换器的车载以太网模块设置为主机(Master)模式。具体设置方式可参考所购转换器的使用说明。
关于如何设置电脑的 IP 地址模式,可查看《Livox HAP 用户手册》。
当多台使用静态 IP 地址的 HAP (T1) 接入同一台电脑时,请确保每台 HAP (T1) IP 地址不同。具体如何设置静态 IP 地址,
可查看《Livox HAP 用户手册》。
Livox HAP 直接连接至外部直流电源时,由于 HAP (T1) 的工作电压为 9-18V DC,因此请确保所连接的外部电源电压
在允许范围内。连接时,请注意电源接口按照正负极正确连接。
下载并安装 livox Viewer 2
用户可前往 Livox 官网 www.livoxtech.com 下载最新的 Livox Viewer 2查看点云图。Livox Viewer 2 目前支持 Windows® 1064 位)
UBUNTU® 18.0464 位)。
HAP (T1) 转换器 电脑
连接外部电源
连接外部电源
连接至转换器的
车载以太网接口
使用以太网线连
接转换器和电脑
LIVOX HAP 快速入门指南
12
1. 下载 Livox Viewer 2 文件。
2. 解压文件,并于已解压的文件中打开文件名为 Livox Viewer 2 的程序。Ubuntu 用户请于解压文件的根目录中打开终端并运行 ./
livox_viewer_2.sh
3. 打开 Livox Viewer 2 时,如果有网络授权的系统窗口弹出,请允许 Livox Viewer 2 的网络访问权限。
4. 打开后左侧为设备管理窗口,右侧为 Livox Viewer 2 主界面。同时,用户也可通过点击 隐藏 / 显示设备管理窗口。若当前局
域网中已有 Livox 设备,管理窗口中将会自动显示该设备。
5. 于管理窗口上方勾选 LiDAR
6. 选择需要查看的 Livox HAP点击图标 完成连接。或选择需要查看的 Livox HAP 后,单击鼠标右键,选择 Connect 完成连接。
7. 连接完成后,点击开始播放图标 或按下键盘上的空格按键,即可观察到所选设备的点云图像。
Windows 系统下使用 Livox Viewer 2 时,由于操作系统的防火墙对网络数据的拦截, 可能导致 Livox Viewer 2 无法扫
描到 LiDAR。若出现此情况,请用户在电脑控制面板中关闭防火墙,然后再重启 Livox Viewer 2
关于 Livox Viewer 2 更详细的使用方法,及每个按钮的详细说明,请查阅《Livox Viewer 2 用户手册》。
低温启动
HAP (T1) 的工作温度为 -40℃至 85℃。当环境温度低于 0℃时,HAP (T1) 上电后会根据自身状态进入自加热模式,温度越低,功率
越大,自加热模式最高功率可达 40W。因此,当于低温环境下使用 HAP (T1) 时,请合理设计电源。
规格参数
型号 HAP (T1)
激光波长 905 nm
人眼安全级别Class 1 (IEC 60825-1:2014) 人眼安全
量程(@100 klx150 m @ 10% 反射率
FOV 120°(水平)×25°(竖直)
测距随机误差(1σ) < 2 cm @ 20 m80% 反射率)
测距系统误差 < ±3 cm @ 20 m
角度随机误差(1σ) < 0.1°
光束发散角度 0.03°(水平)×0.28°(竖直)
点云输出 452,000 /
数据网口 100BASE-T1 车载以太网
数据同步方式 gPTP
虚警率 (@100 klx) 0.01%
工作环境温度 -40℃至 85
存储环境温度 -40℃至 95
防护级别 IP67
功率额定功率 12 W
启动功率 26 W
低温加热功率 40 W
供电电压范围9-18 V DC
噪音 < 45 dB(A) 40 cm 全方向)
尺寸 105×131.6×65 mm
重量 1120 g
IMU
激光探测测距仪中内置激光器辐射光的发散角为 25.2°(水平)×8°
(竖直)(半高宽,FWHM),最大激光功率可能达到 65 W。切勿拆
HAP (T1),以免造成危险。
当被测物体距离 HAP (T1) 小于 0.5 m 时,HAP (T1) 无法对其进行测量。
测试条件为环境温度 25℃。 具体指标与测试条件相关,以实测结果为
准。被测物处于 0.5~2m 的范围内时HAP (T1) 的点云图像可能会产
生不同程度的畸变。
100klx 日光条件下,环境温度 25℃,环境杂散光产生的虚警噪点
的比例。
HAP (T1) 在接有电源线和车载以太网线的状态下,可达到 IP67 防护
级别。若未连接线材,防护级别为 IP54
在低温环境下HAP (T1) 将自动运行自加热模式,最大功率可达
40W,请合理设计电源。
请确保所使用的电源,其输出电压无论何时都不可超过此范围。
13
LIVOX HAP クイックスタートガイド
16
LIVOX™Technology Company Limited (Livox) www.livoxtech.com
Livox
LIVOX www.livoxtech.com
LIVOX
LIVOX
A B
LIVOX
LIVOX
LIVOX
LIVOX
Livox
1. Livox HAP™
2. Livox HAP Livox HAP 10 mm
Livox HAP
3. Livox HAP
Livox HAP
4. Livox HAP Livox HAP
5. Livox HAP
Livox
6. Livox HAP 1 IEC/EN 60825-1: 2014
14
LIVOX HAP クイックスタートガイド
1.
2. 1
3. M6 ( 6.5) 4
4. Ethernet (100BASE-T1)
5.
6. M3 4
7. 2
8.
HAP (T1)
8
7
1
2
3
4
5
6
7.
8. Livox HAP
9. Livox HAP
Livox HAP Livox Horizon LiDAR Livox HAP
Livox HAP Livox
Horizon 120 25 FOV150 m10% 100 klux 452,000 /
Livox Viewer 2
Livox SDK 3D
Livox HAP HAP (T1) HAP (TX) 2 HAP (T1)
FOV
HAP (T1) FOV 120 25 HAP (T1) FOV
www.livoxtech.com/hap HAP (T1) 3D FOV
120°
25°
15
LIVOX HAP クイックスタートガイド
HAP (T1) FOV FOV
FOV
10
m
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60°
60°
200
175
150
125
100
75
50
45°
30°
10° 15°
-15°
HAP (T1)
HAP (T1)
0.65
92.65
3±0.05
62
1
54
2
94.6
48.5
121.6
91.6
47
131.6
105
65
3±0.05 1
4-M3 5
4- 6.5±0.1
mm
-5°
-10°
200
175
150
125
100
50
75
15°
-15°
-30°
-45°
-60° 60°
200
175
150
125
100
75
50
45°
30°
10°
15°
-15°
16
LIVOX HAP クイックスタートガイド
HAP (T1) Ethernet
HAP (T1) Ethernet
HAP (T1) Ethernet
1
2
3
4
5
6
78
AHAP (T1) ATE 1-967616-1 B B
XT30
A
A
B
B
MDI+
MDI-
Ethernet
AHAP (T1) Ethernet A TE 1802105-1 B Ethernet
Ethernet B MOLEX 347910040
1 + DC VCC
DC
4
7 MDI+ 100Base-T1 Ethernet
Ethernet
8MDI- 100Base-T1
2
3
5
6
HAP (T1)
HAP (T1) IP IP 192.168.1.100 HAP (T1)
255.255.255.0 192.168.1.1
100BASE-T1 Ethernet 100BASE-TX Ethernet
Ethernet HAP (T1)
1. IP IP IP HAP
A
A
B
BVCC
17
LIVOX HAP クイックスタートガイド
a. Ethernet HAP (T1) Ethernet Ethernet
b. HAP (T1)
c.
d. Ethernet
3. Ethernet
IP Livox HAP
HAP (T1) LiDAR IP 1
IP LiDAR IP
Livox HAP
HAP (T1) DC 9 18 V Livox HAP
Livox Viewer 2
http://www.livoxtech.com Livox Viewer 2 Livox
Viewer 2 WINDOWS ®1064 UbuntuTM 18.0464
1. Livox Viewer 2
2. Livox Viewer 2 Livox Viewer 2.exe .exe Ubuntu
Livox Viewer 2 ./livox_viewer_2.sh
3. Livox Viewer 2 Livox Viewer 2
4. Livox Viewer 2
LAN Livox LiDAR
5. LiDAR
6. Livox HAP Livox HAP
7.
HAP (T1)
Ethernet
Ethernet
(T1) IP 192.168.1.50
255.255.255.0
2. HAP (T1)
18
LIVOX HAP クイックスタートガイド
• Windows Windows Livox Viewer 2 LiDAR
Windows Livox
Viewer 2
Livox Viewer 2 Livox Viewer 2
HAP (T1) -40 85 0HAP (T1)
40 W
HAP (T1)
905 nm
1IEC 60825-12014
@100 klx 150 m @ 10%
FOV 120 25
1< 2 cm @ 20 m80%
< 3 cm @ 20 m
1 < 0.1
0.03 ( ) 0.28 ( )
452,000 /
100BASE-T1 Ethernet
gPTP
(@100 klx)
0.01%
-40 85
-40 95
IP IP67
12 W
26 W
40 W
DC9 18 V
< 45 dB(A)40 cm
105 131.6 65 mm
1120 g
IMU
25.2 8
65 W
HAP (T1)
HAP (T1) 0.5 m
25
0.5
2 m
25 100 klx
HAPT1
IP IP67 2
HAPT1 IP IP54
HAP (T1)
40 W Livox HAP
HAP (T1)
19
LIVOX HAP
16 .
.
. , .
. , LIVOX™ Technology Company
Limited(Livox) (www.livoxtech.com) .
.
. , Livox
, .
. LIVOX A/S
(www.livoxtech.com)
. LIVOX ,
LIVOX A/S . (A)
, , , (B) , .
LIVOX LIVOX , ,
, , .
, LIVOX
.
, .
, , (
LIVOX ) 3
. .
LIVOX , .
.
.
1. Livox HAP™ .
. .
2. Livox HAP Livox HAP 10mm
. Livox HAP .
3. Livox HAP . . ,
. Livox HAP
.
4. Livox HAP , Livox HAP .
.
5. Livox HAP . Livox
.
6. Livox HAP 1 (IEC/EN 60825-1: 2014) .
7. .
8. Livox HAP .
9. Livox HAP . .
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Livox T1 HAP ユーザーガイド

タイプ
ユーザーガイド

他の言語で