Edge-Core AS5712-54X ユーザーマニュアル

タイプ
ユーザーマニュアル

このマニュアルも適しています

– 1 –
1. Unpack the Switch and Check Contents
AS5812-54T
Rack Mounting Kit—2 front-post brackets, 2 rear-post
brackets, 20 screws, and 2 ear-locking screws
Power Cord (included with AC PSUs only)
Ground Wire (included with DC PSUs only)
Console Cable—RJ-45 to DB-9
DC Power Cable (included with 48 VDC PSU only)
Documentation—Quick Start Guide (this document)
and Safety and Regulatory Information
Note:
The switch has the Open Network Install
Environment (ONIE) software installer pre-loaded on the
switch, but no switch software image. Information about
compatible switch software can be found at
www.edge-core.com.
Caution:
The switch includes plug-in power supply (PSU)
and fan tray modules that are installed into its chassis. All
installed modules must have a matching airflow direction.
That is, if the installed power modules have a front-to-back
(F2B) airflow direction, all the installed fan tray modules
must also have a F2B airflow direction.
Note:
The switch drawings in this document are for
illustration only and may not match your particular switch
model.
2. Attach the Brackets
Attach each of the front- and rear-post brackets to the
switch using four of the included bracket screws.
Use an additional two screws to secure each of the rear-post
brackets at the mid-point on the sides of the switch.
3
1
1
2
1
2
Use the screws and cage nuts supplied with the rack to
secure the switch in the rack.
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack,
while the other secures it using the rack screws.
装置の吸気に必要な領域 ル上に規定
いる。
3. Adjust Rear-Post Bracket Ears
Lock the position of the rear-post bracket ears using the
included position-locking screws.
You can also adjust the rear-post bracket ears to fit different
rack depths from 56 cm to 75 cm.
4. Ground the Switch
Ensure the rack is properly grounded and in compliance
with ETSI ETS 300 253. Verify that there is a good electrical
connection to the grounding point on the rack (no paint or
isolating surface treatment).
Attach the grounding wire #14 AWG to the grounding point
on the switch rear panel. Then connect the other end of the
wire to rack ground.
For details on grounding the switch with a 12 VDC PSU in an
Open Rack, refer to the Edgecore ORSA-1U Open Rack Tray
Set Installation Guide.
Caution:
The earth connection must not be removed
unless all supply connections have been disconnected.
3
1
1
1
2
1
2
E122017-AP-R03
150200001294A
www.edge-core.com
54-Port 10G / 40G Copper Ethernet Switch
AS5812-54T
Quick Start Guide
– 2 –
5. Connect Power
Install one or two AC or DC power modules in the switch.
The switch supports up to two PSUs that must have the
same matching airflow direction as the installed fan tray.
Connect an external AC or DC power source to the modules.
36 75 VDC Return (blue
wire)
Chassis Ground (yellow-
green wire)
-36
-75 VDC (brown
wire)
Open Rack tray connector
for 12 VDC PSU
Caution:
Use a UL/IEC/EN 60950-1 certified power supply
to connect to a DC converter, and a #14 AWG (for 36–75 VDC
PSU) or #10 AWG (for 12 VDC PSU) wire to connect to a DC
PSU.
6. Verify Switch Operation
Verify basic switch operation by checking the system LEDs.
When operating normally, the PSU1/PSU2, Diag, and Fan
LEDs should all be on green.
2
1
1
2
3
2
1
4
1
3
2
4
1
1
7. Perform Initial System Boot
If the network operating system (NOS) installer is located on
a network server, first connect the RJ-45 Management
(Mgmt) port to the network using 100-ohm Category 5, 5e
or better twisted-pair cable. (Not required if the NOS
installer is located on attached storage.)
Boot the switch. Wait for the ONIE software to locate and
execute the NOS installer, and then wait for the installer to
load the NOS software image.
Subsequent switch boots will bypass ONIE and directly run
the NOS software.
Note:
For switches with ONIE software pre-loaded, refer to
the network operating system (NOS) installer and NOS
documentation for details on software options and set up
for ONIE.
8. Connect Network Cables
For RJ-45 ports, use 100-ohm Category 6, 6a, or 7 twisted-
pair cable for 10GBASE-T connections, or Category 5e or
better cable for 100/1000BASE-T connections.
Connect DAC cables to the QSFP+ slots. Or, first install
QSFP+ transceivers and then connect fiber optic cabling to
the transceiver ports.
The following transceivers are supported:
40GBASE-CR4
40GBASE-SR4
Note:
As connections are made, check the port status LEDs
to be sure the links are valid.
9. View the Product Label
The switch product label is located below RJ-45 ports 7–12
on left side of the front panel. Pull the label out to view the
product information.
1
2
2
1
1
2
1
Quick Start Guide
– 3 –
Hardware Specifications
Switch Chassis
Size (WxDxH) 442.5 x 473 x 43.95 mm (17.42 x 18.62 x 1.73 inches)
Weight 9.5 kg (20.94 lb), with two installed PSUs
Temperature Operating: 0° C to 40° C (32° F to 104° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power
Consumption
384 Watts maximum
AC PSU
Power Rating 100–240 VAC, 50-60 Hz, 400 Watts
AC Input 100–240 VAC, 50-60 Hz, 6–3 A
DC Output 5 VSB @ 3 A, 12 VDC @ 33 A
48 VDC PSU
Power Rating 48 VDC, 400 Watts
DC Input 36–75 VDC, 16 A maximum
DC Output 5 VDC @ 0.5 A, 12 VDC @ 33 A
12 VDC PSU (PSU-12V-650)
DC Input 12 VDC (from Open Rack busbar)
Regulatory Compliances
Emissions EN 55032:2012/AC:2013, Class A
EN 61000-3-2:2014
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CE Mark
CCC GB 9254-2008, Class A
BSMI EMI Standard CNS 13438:2006
Immunity EN 55024:2010
IEC 61000-4-2:2008
IEC 61000-4-3:2006/A1:2007/A2:2010
IEC 61000-4-4:2012
IEC 61000-4-5:2014
IEC 61000-4-6:2013
IEC 61000-4-8:2009
IEC 61000-4-11:2004
Safety UL (CAN/CSA C22.2 No. 60950-1 & UL60950-1)
CB (IEC/EN60950-1)
CCC GB4943.1-2011
BSMI Safety Standard CNS14336-1
Taiwan RoHS CNS 15663
Quick Start Guide
– 4 –
3
1
1
2
1
2
装置の吸気に必要な領域 ル上に規定
いる。
3
1
1
1
2
1
2
AS5812-54T
– 5 –
2
1
1
2
3
2
1
4
1
3
2
4
1
1
1
2
2
1
1
2
1
– 6 –
° ° ° °
° ° ° °
AC PSU
48 VDC PSU
,
12 VDC PSU (PSU-12V-650)
– 7 –
1.
AS5812-54T
x2 x2
x20 x2
AC PSU
DC PSU
RJ45 DB-9
DC 48 VDC PSU
ONIE
www.edge-core.com
F2B
F2B
2.
3
1
1
2
1
2
装置の吸気に必要な領域 ル上に規定
いる。
3.
56 cm
75 cm
4.
ETSI ETS 300
253
14 AWG
12 VDC PSU
Edgecore ORSA-1U Open Rack Tray Set
3
1
1
1
2
1
2
54 10G / 40G
AS5812-54T
– 8 –
5.
1 2 AC DC
2 PSU PSU
AC DC
36 75 VDC Return
Chassis Ground
-36 -75 VDC 12 VDC PSU
DC Converter UL/IEC/EN
60950-1 DC PSU #14
AWG 36 VDC 75 VDC PSU #10
AWG 12 VDC PSU DC PSU
6.
LED
PSU1/PSU2 Diag LED
2
1
1
2
3
2
1
4
1
3
2
4
1
1
7.
NOS
5-ohm 5 5e
RJ-45 Mgmt NOS
ONIE NOS
NOS
ONIE NOS
ONIE
NOS NOS
8.
RJ-45 1 0GBASE-T 100-
ohm 6 6a 7 , 100/1000BASE-T
5
DAC
QSFP+
40GBASE-CR4
40GBASE-SR4
LED
9.
RJ-45 7-12
1
2
2
1
1
2
1
– 9 –
(WxDxH)
442.5 x 473 x 43.95 mm (17.42 x 18.62 x 1.73
9.5 kg (20.94 lb) PSU
: 0° C to 40° C (32° F to 104° F)
: -40° C to 70° C (-40° F to 158° F)
: 5% to 95%
384
AC PSU
100–240 VAC 50-60 Hz 400
AC
100–240 VAC, 50-60 Hz, 6–3 A
DC
5 VSB @ 3 A, 12 VDC @ 33 A
48 VDC PSU
48 VDC 400
DC 36–75 VDC 16 A
DC
5 VDC @ 0.5 A, 12 VDC @ 33 A
12 VDC PSU (PSU-12V-650)
DC 12 VDC
EN 55032:2012/AC:2013, Class A
EN 61000-3-2:2014
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CE Mark
CCC GB 9254-2008, Class A
BSMI EMI Standard CNS 13438:2006
EN 55024:2010
IEC 61000-4-2:2008
IEC 61000-4-3:2006/A1:2007/A2:2010
IEC 61000-4-4:2012
IEC 61000-4-5:2014
IEC 61000-4-6:2013
IEC 61000-4-8:2009
IEC 61000-4-11:2004
UL (CAN/CSA C22.2 No. 60950-1 & UL60950-
1)
CB (IEC/EN60950-1)
CCC GB4943.1-2011
BSMI Safety Standard CNS14336-1
RoHS
CNS 15663
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Edge-Core AS5712-54X ユーザーマニュアル

タイプ
ユーザーマニュアル
このマニュアルも適しています

他の言語で