dji AGRAS MG-1S Series, Assistant 2 for MG, MG-1S ユーザーガイド

  • こんにちは!DJI 霧滴分析計 DA4231 のユーザーガイドの内容をすべて読み終えました。このデバイスの使い方、データ分析方法、メンテナンス方法など、あらゆる質問にお答えできます。例えば、バッテリーの種類、試験紙の選び方、アプリとの連携方法など、お気軽にご質問ください!
  • バッテリーはどこで購入できますか?
    どんな種類の試験紙を使用すれば良いですか?
    分析計のレンズが汚れた場合はどうすれば良いですか?
    長期間使用しない場合はどうすれば良いですか?
    アプリを分析計に紐づけるにはどうすれば良いですか?
User Guide
使用说明
ユーザーガイ
사용자 가이드
2017.05V1.0
Droplet Analyzer
1
Contents
EN
KR
CH
JP
User Guide
2
使用说明
8
ユーザーガイド
14
사용자 가이드
20
EN
2
Disclaimer
Thank you for purchasing Droplet Analyzer (hereinafter referred to as the
“Product”). Read this disclaimer carefully before using this Product. By using
this Product, you hereby agree to this disclaimer and signify that you have
read it fully. Please use this Product in strict accordance with the manual
and be sure to pay attention to the Warnings. SZ DJI TECHNOLOGY CO.,
LTD., and its afliated companies assume no liability for damage(s) or injuries
incurred directly or indirectly from using, installing or refitting this product
improperly, including but not limited to using non-designated accessories
such as a battery, test paper or app.
DJI
TM
is a trademark of SZ DJI TECHNOLOGY CO., LTD. (abbreviated as “DJI”)
and its afliated companies. Names of products, brands, etc., appearing in
this manual are trademarks or registered trademarks of their respective owner
companies. This Product and manual are copyrighted by DJI with all rights
reserved. No part of this Product or manual shall be reproduced in any form
without the prior written consent or authorization of DJI.
This disclaimer is produced in various languages. In the event of divergence
among different versions, the Chinese version shall prevail when the Product
in question is purchased in China, and English version shall prevail when the
Product in question is purchased in any other region.
Warnings
1. The Droplet Analyzer does not come with a battery. Please purchase an
approved 9 V battery. DO NOT use leaking or damaged batteries.
2. The Droplet Analyzer analyzes droplet information after obtaining a sample
on the test paper. Analysis results may vary according to different types of
test paper. Use water-sensitive paper from an established manufacturer to
reduce research bias.
3. Be sure to keep the lens clean. If dirty, wipe it with the lens cleaning cloth
included.
4. Remove the battery from the analyzer and put it into the toolbox if unused
for extended periods.
EN
3
Introduction
The Droplet Analyzer comes equipped with a high-precision lens module
designed for agricultural applications, with the ability to take photos with a
smart mobile device. Droplet information is easily obtained and analyzed with
the DJI Droplet Analyzer app, providing reliable data support for precision
agriculture. Its compact structure and easy-to-use features make it ideal for
single-person droplet analysis.
In the Box
Droplet Analyzer × 1
Toolbox × 1
Suction Cup Set × 1
Lens Cleaning Cloth × 1
EN
4
Overview
Lighting
System
Power Button
Power
Indicator
Lens
Suction
Cups
Battery
Compartment
Cover
Usage
Download the DJI Droplet Analyzer
Search “Droplet Analyzer” in Google Play, and download the app to your
mobile device.
The app supports Android 5.0 or later.
Binding Device
The app can only be used by binding it to the analyzer via the Internet.
1. Scan the QR code on the body of the analyzer or type in the serial number.
Each QR code or serial number will bind the app to up to ve mobile devices.
2. To unbind the Droplet Analyzer, tap the
icon in the upper right corner of
the app then, Bound Device > Unbind.
Installing the Battery
A 9 V battery is required.
EN
5
1. Push the battery compartment cover out.
2. Insert the 9 V battery into the compartment. Check that the positive and
negative terminals are correctly aligned. Push again to ensure secure
installation.
3. Remount the cover.
Turning the Analyzer On/Off
Turning On: Press and hold the power button for two seconds to turn it on.
The lighting system will switch on, and the power indicator will show a solid
green light, indicating a normal start. A solid red light indicates low battery
level. Replace the battery as soon as possible.
Turning Off: Press and hold the power button for two seconds to turn it off.
The power indicator and the lighting system will turn off. The analyzer will turn
off automatically if idle for more than eight minutes after being switched on.
Fixing the Analyzer
1. Align the lens of the analyzer to the camera of your mobile device with the
suction cups facing the device. Press the analyzer to x it on the mobile
device via the suction cups.
2. Adjust the position of the analyzer so that all the suction cups are attached
to the mobile device sticking to the analyzer.
Droplet Analysis
Droplet
Analyzer
App
Place the test paper where you want to do droplet analysis on the plants. Spray
the liquid, then run the app and follow the instructions below for droplet analysis.
Data Collection
1. Tap “New Task”.
EN
6
2. Type “Task Name”, “Operator”, “Time”.
3. Select “Area of Test Paper”.
4. Type “Ground Length” and “Sample Space”. The app will display the value
of “Estimated Sample Number”.
5. Tap “+” under “Import Photo” to enter Shooting View.
a. Place the test paper onto a at surface. Align the lens of the analyzer to
the desired shooting area and stick the analyzer to the paper.
b. Roll the menu in the lower right corner of the screen to change the
sample location.
c. Tap the screen to select an area for focusing, then tap the shutter
button
.
d. The area selecting tool will appear on the screen. Drag the box in the
middle to select the desired area. Drag the dots around it to change the
size of the area.
e. After selecting the area, tap “Complete” to end shooting or tap “Take
next photo”.
f. After importing your photos, tap a photo to see its corresponding
information. Tap the photo under “Photo Info” to show detected
droplets. If the information is inaccurate, tap the delete icon
or
“Replace Photo” to import the photo again.
Always use the lens of the analyzer when taking photos. Make
sure that there is no space between the analyzer and test paper
to avoid extra sources of light, which may compromise droplet
information accuracy.
Use the Gradienter in the upper right corner of Shooting View
to check whether the mobile device is horizontal when taking
photos. The mobile device is adjusted to level when the dot of the
Gradienter is coincident with the central cross, turning green.
6. Tap “More Info” to congure Spray Info, Environment Info, Flight Info, and
Crop Info, then tap “Save”.
7. After conguring all the settings, tap “Save”.
EN
Data Analysis
In the task list in Data Collection View, swipe one task to the left to edit or
delete the task. Tap the desired task and the app will show you the results of
the analysis.
1. Coefficient of Variation: Indicates the distribution of the droplets. The
smaller the value, the more uniform the distribution.
2. Coverage Rate and Drop: Select/clear to show/hide the corresponding item.
3. Display Value: Select/clear to show/hide the value of each sample location.
4. Landscape: Select/clear to show the results in landscape/portrait.
5.
Photo Info: Tap to view the results of the analysis for each photo at its
corresponding sample location, such as drop number, diameter, coverage,
and distribution. You can enter Photo Info by tapping the sampling point
on the polyline. Tap the photo under Photo Info to show the detected
droplets. Tap “<”/“>” to show the previous or next photo.
6. Swipe to the left to view task information. Tap “<”/“>” to show the previous
or next task. Tap “Edit” for conguration.
More
Tap the
icon on the upper right corner of Data Collection View for more
functions i.e. Bound Device, Feedback, APP Version, and Clear all tasks.
Specications
Model DA4231
Dimensions 96 mm × 46 mm × 45 mm
Weight (Battery Excluded) 134 g
Power 1.5 W
Battery 9 V alkaline or 9 V NiMH rechargeable
batteries recommended.
DJI is a trademark of DJI.
Copyright © 2017 DJI All Rights Reserved.
This content is subject to change.
Download the latest version from
http://www.dji.com/mg-1s
CH
8
免责声明
感谢您购买雾滴分析仪。在使用之前,请仔细阅读本声明,一旦使用,
即被视为对本声明全部内容的认可和接受。请严格遵守本文安装和使用
该产品,并务必重视注意事项。因用户不当使用、安装、改装(包含但
不限于使用非 DJI
TM
指定的零配件,如:电池、试纸App 等)造成的
任何损失,深圳市大疆
TM
创新科技有限公司及其关联公司将不承担任
何责任。
DJI 是深圳市大疆创新科技有限公司及其关联公司的商标。本文出现的
产品名称、品牌等,均为其所属公司的商标或注册商标。本产品及文
档为深圳市大疆创新科技有限公司版权所有。未经许可,不得以任何
形式复制翻印。
关于不同语言版本的免责声明可能存在的语义差异,中国以中文版为准,
其他地区以英文版为准。
注意事项
1. 雾滴分析仪不包含电池,用户需自行购买 9V 电池。切勿使用存在破
损、漏液等情况的电池。
2. 雾滴分析仪通过获取试纸上的雾滴样本进行雾滴分析,使用不同试
纸所得的分析结果会有所不同。请选用正规厂商的水敏纸,否则可
能导致分析结果与实际情况偏差较大。
3. 务必保持镜头清洁,若有异物请使用包装内的镜头清洁布擦拭。
4. 若长期不使用分析仪,需取出电池并将分析仪放置在工具箱中。
CH
9
简介
雾滴分析仪专为农业领域设计,配备高精度镜头模组,在可拍照的智能
移动设备上配合定制的 DJI 雾滴分析仪 App 使用,能够准确地获取并
分析试纸上的雾滴信息,为精准农业提供可靠的数据支持。分析仪体积
小巧,简单易用,单人即可实现田间雾滴分析工作。
物品清单
雾滴分析仪 ×1
工具箱 ×1
吸盘 ×1
镜头清洁布 ×1
CH
10
使用
下载 DJI 雾滴分析仪 App
在软件商店搜索“雾滴分析仪”,下载并安装至移动设备。
目前仅可于 Google Play、华为应用市场及腾讯应用宝平台进
行下载,可下载平台将持续更新,请访问 DJI MG-1S 产品页
面查看详细列表。
App 要求使用 Android 5.0 及以上系统。
绑定设备
App 需要绑定分析仪方可使用。绑定时确保移动设备已接入互联网。
1. 使用 App 扫描分析仪上的二维码,或在 App 中输入序列号即可。每
个二维码(序列号)最多可与 5 部移动设备上的 App 绑定。
2. 如需解除绑定,点击 App 右上角的 图标 > 设备绑定 > 解除绑定。
部件名称
照明系统
电源开关
电源指示灯
镜头
吸盘
电池仓盖
CH
11
安装电池
请自备 9V 电池。
1. 推开电池仓盖。
2. 9V 电池装入电池仓,注意正负极对应。稍加用力确保电池安装
稳固。
3. 装回电池仓盖。
开启 / 关闭分析仪
开启:长按分析仪的电源开关 2 秒以开启分析仪。照明系统点亮且电源
指示灯显示绿灯常亮表示正常启动;电源指示灯显示红灯常亮表示电池
电量低,请尽快更换电池,以免影响正常使用。
关闭:在分析仪开启的状态下,长按电源开关 2 秒以关闭分析仪,电源
指示灯和照明系统将熄灭。分析仪开启后闲置超过 8 分钟也会自动关闭。
固定分析仪
1. 将分析仪带吸盘的一面贴近移动设备,使分析仪的镜头对准移动设
备的摄像头。按压分析仪,通过吸盘将其固定至移动设备。
2. 适当调整分析仪角度,使尽可能多的吸盘吸附至移动设备,以确保
稳固。
雾滴分析
雾滴分析仪
APP
将试纸放置于需要分析雾滴的位置(植物的顶部、中部或根部),并进
行喷洒。运行 App,然后按照以下方法进行雾滴分析。
CH
12
数据采集
1. 点击“新建任务”。
2. 输入“任务名称”、“作业者”、“时间”。
3. 选择“试纸放置区域”。
4. 输入“场地长度”“采样间距”App 将显示“预计需要采样张数”
5. 点击“导入照片”下方的“+”,进入拍照界面。
a. 将试纸放置于平整的平面上,使分析仪镜头对准需要拍照的位置,
并贴紧试纸。
b. 滑动右下角菜单可更改采样位置。
c. 点击屏幕选择对焦点,然后点击拍照按钮
d. 屏幕显示照片区域选择工具。拖动中间的方框选择所需区域,拖
动四周的圆点改变区域大小。
e. 区域选择完成后,可选择“完成”结束拍照,或选择“继续拍下
一张”。
f. 导入照片后,可点击照片查看照片信息。点击照片信息中的照片,
可显示检测到的雾滴。若照片信息不准确,可选择删除
或替换
照片以重新导入。
务必配合分析仪镜头拍摄照片,并确保分析仪贴紧试纸以避
免外界光线进入镜头,否则将无法获取准确的雾滴信息。
拍照时,如有需要,可使用拍照界面右上方的水平仪观察移
动设备是否水平。水平仪的圆点与中心十字重合且变为绿色
时表示移动设备已调至水平。
6. 点击“更多信息”,设置喷洒信息、环境信息、飞行信息和作业信
息并保存。
7. 所有设置完成后,点击“保存”。
CH
数据分析
在数据采集界面的任务列表中,向左滑动任务可编辑或删除相应任务;
点击需要查看的任务,App 将显示分析结果。
1. 变异系数:表示雾滴的分布情况,变异系数越小分布越均匀。
2. 覆盖率、雾滴:勾选 / 取消将显示 / 隐藏此项分析结果。
3. 显示值:勾选 / 取消将显示 / 隐藏各个采样位置对应的数值。
4. 横屏:勾选 / 取消将横屏 / 竖屏显示分析结果。
5.
照片信息:点击可查看每个采样位置对应照片的雾滴个数、直径、
覆盖率、分布情况等分析结果。点击折线上的采样点
亦可进入照
片信息。点击照片可显示检测到的雾滴,点击“</>”切换至上
一张 / 下一张照片。
6. 向左滑动可查看任务信息,点击右上角的</>”切换至上一
/ 下一个任务,点击“编辑”可修改信息。
更多
点击数据采集界面右上角的 图标,可进行以下操作:设备绑定、用
户反馈、查看 App 版本、清空所有任务。
规格参数
型号 DA4231
尺寸 96 mm×46 mm×45 mm
重量(不含电池) 134 g
功率 1.5 W
电池 推荐使用 9V 碱性电池或 9V 镍氢充电电池
DJI 是大疆创新的商标。
Copyright © 2017 大疆创新 版权所有
内容如有更新,恕不另行通知。
您可以在 DJI 官方网站查询最新版本
http://www.dji.com/mg-1s
JP
14
SZ DJI TECHNOLOGY
CO., LTD.
DJI
TM
SZ DJI TECHNOLOGY CO., LTD. DJI
DJI DJI
1. 9V
2.
3.
4.
JP
15
DJI Droplet Analyzer
×
1
×
1
×
1
×
1
JP
16
DJI Droplet Analyzer のダウンロ
Google Play Droplet Analyzer
Android 5.0
モバイルデバの紐づけ
1. QR QR
5
2.
>
JP
17
ッテリー 取り付
9V
1.
2. 9V
3.
散布分析計の電源オン/
電源をオンにす 2
る: 2
8
分析計の固定
1.
2.
散布分析
Droplet
Analyzer
アプリ
JP
18
ータ収集
1.
2.
3.
4.
5. +
a.
b.
c.
d.
e.
f.
6.
7.
JP
ータ分析
1.
2.
3.
4.
5.
</>
6. </>
追加機能
DA4231
96mm
×
46mm
×
45mm
134g
1.5W
9V 9V NiMH
DJI DJI の商標です
Copyright © 2017 DJI All Rights Reserved.
最新版は下記ンロださい。
http://www.dji.com/mg-1s
/