CG01D, CG451, CG752D & CG90D
models
GAS-ON-GLASS COOKTOP
INSTALLATION GUIDE
HK SG
INSTALLATION GUIDE
3
IMPORTANT!
SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our
website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.
IMPORTANT SAFETY INSTRUCTIONS
Particular attention shall be given to
the relevant requirements regarding
ventilation.
Read these instructions carefully before
installing this product.
Please make this information available
to the person installing the appliance
as it could reduce your installation
costs.
This appliance is to be installed and
serviced only by an authorised person.
Installation must comply with your local
building and local gas authority codes
and electricity regulations.
Incorrect installation, for which the
manufacturer accepts no responsibility,
may cause personal injury or damage
and could invalidate any warranty or
liability claims.
Appliances are factory set for LPG or
Town Gas. If in doubt, refer to the local
gas network operator of gas supplier to
confirm gas type at the installation site.
1 SAFETY AND WARNINGS
WARNING!
Electrical shock hazard
Disconnect the appliance from
the mains electricity supply
before carrying out any work or
maintenance on it.
Connection to a good earth wiring
system is essential and mandatory.
Alterations to the domestic wiring
system must only be made by a
qualified electrician.
Failure to follow this advice may
result in electrical shock or death.
WARNING!
Cut Hazard
Take care - panel edges are sharp.
Failure to use caution could result
in injury or cuts.
!
!
4
IMPORTANT SAFETY INSTRUCTIONS
If in doubt, refer to the local gas
network operator or gas supplier to
confirm gas type at installation site.
Do not modify this appliance.
Do not use or store flammable
materials on or near this appliance.
Do not spray aerosols in the vicinity of
this appliance while it is in operation.
Packing elements (eg plastic bags,
polystyrene foam, staples, packing
straps etc) and tools should not be left
around during and after installation,
especially if they are within easy reach
of children, as these may cause serious
injuries.
You must remove the transit screws
before installing the cooktop. See step
8 of installation instructions.
Before you install the appliance, please
make sure that
the local distribution conditions (nature
of gas and pressure) and the adjustment
of the appliance are compatible. For
adjustment conditions for this appliance
see ‘Gas rate summary’.
a suitable disconnection switch is
incorporated in the permanent wiring,
mounted and positioned to comply with
the local wiring rules and regulations.
A means of disconnection with at least
a 3 mm air gap contact separation in
all poles must be incorporated into the
fixed wiring in accordance with the
wiring rules, unless the local wiring rules
allow for alternative means.
the appliance is connected to a 220V
- 240V 50Hz (10 A) power supply only
and earthed via the power supply cable.
there is a power outlet within reach of
the power supply cable (900 mm from
the centre rear of the product). This
must be accessible after installation.
The power supply cable should not
touch any metal parts.
1 SAFETY AND WARNINGS
5
if the power supply cable is damaged,
it is replaced only by the special cable:
Part no. 534906 TRMNL BLOCK-FLEX
ASSY HITEMP GOG UK, obtainable
from authorised Fisher & Paykel Service
Agents. Please see your ‘Service and
Warranty’ booklet for contact details.
the supply connection point (gas shut-
off valve) is accessible after installation.
the benchtop is made of a heat resistant
material.
the installation complies with all the
current requirements of National and
Local Authority Gas, Electric and other
relevant Codes and Regulations.
When you install the appliance
As servicing requires removing of the
cooktop from the benchtop we do not
recommend flush mounting. To the
fullest extent permissible by law, the
owner carries all risk for flush mounting
of the cooktop. The owner must ensure
the cooktop has been cut out from the
benchtop before servicing can be carried
out. Fisher & Paykel will not be liable
for any costs associated with removing
or replacing a flush-mounted and/or
sealed-in product, nor for repairing any
damage that may be incurred by doing
this. Fisher & Paykel does not exclude
any statutory liability it may have and
which by law cannot be excluded,
because of the giving of this notice.
If installed with an approved flexible
hose, the hose should not come
in contact with the bottom of the
appliance or any sharp edges. Flexible
hose assemblies should comply with
local regulations.
Seal exposed bare edges of the cutout
with an oil-based paint or moisture-
proof polyurethane to prevent possible
moisture creeping between the cooktop
trim and the benchtop.
Take extreme care not to chip, crack,
or break the top glass surfaces during
installation. A heavy metal tool or part
accidentally dropped on the glass could
damage it.
If, after following the instructions
given, correct performance cannot be
achieved, please contact your nearest
Fisher & Paykel Authorised Service
Centre, Customer Care, or contact us
through our website listed on the cover
of this document.
1 SAFETY AND WARNINGS
6
2 PARTS SUPPLIED
Small pan support (1)
(some models only)
Dual Wok Pan support
(1 per Dual Wok)
Wok stand
(1 per Dual Wok)
Gas Elbow (1)
Clamping brackets
(4) and screws (4)
Fibre washers (1)
Installing multiple products
Note: We recommend installing multiple products in separate cutouts, with a minimum 5mm space between the glass edges of the adjacent products.
If installing multiple products adjacent to each other within the same cutout, a separate joining strip kit is required for installation.
The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our website listed on the cover of this document.
If installing different products adjacent to each other (eg a wok burner next to an induction cooktop), the minimum clearance measurements for the different
products may vary. Always use the greater distance.
Semi-rapid Pan
support (1)
(CG903D only)
Elbow 1/2“ BSP
external thread (1)
7
3 GAS RATE SUMMARY
CG301DCG451DCG903D
CG752D
SEMI-RAPID
DUAL WOK DUAL WOK
DUAL WOK DUAL WOK
DUAL WOK
DUAL WOK
Check the ‘Gas type’ sticker on the base of the appliance.
HONG KONG
SINGAPORE
GAS TYPE
CG301D CG451D CG752D CG903D
DUAL WOK DUAL WOK DUAL WOK SEMI-RAPID DUAL WOK
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating (kW)
TG (G110)
(1.5 kPa/15 mbar)*
2.50
2.50
1.30
6.00 2.50
2.50
1.30
5.80 2.30
2.30
1.10
4.70 1.55 1.60 2.30
2.30
1.10
4.70
LPG (G30)
(2.9 kPa/29 mbar)*
0.75
0.75
0.50
5.50 0.80
0.80
0.50
4.86 0.73
0.73
0.50
4.86 0.76 2.36 0.73
0.73
0.50
4.86
GAS TYPE
CG451D CG752D CG903D
DUAL WOK DUAL WOK SEMI-RAPID DUAL WOK
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating
(kW)
Jet size
(mm)
Nominal
rating (kW)
TG (G110)
(0.8 kPa/8 mbar)*
2.50
2.50
1.30
4.60 2.50
2.50
1.30
4.60 2.07 2.05 2.50
2.50
1.30
4.30
LPG (G30)
(2.9 kPa/29 mbar)*
0.73
0.73
0.50
5.00 0.73
0.73
0.50
5.00 0.76 2.28 0.73
0.73
0.50
5.00
*Nominal pressure with one dual wok burner on High.
8
A
KD
B
E
C
G
F
J
H
I
4 PRODUCT & CABINETRY DIMENSIONS
Note: Gas inlet connection is located in the
rear right corner.
FRONT
TOP
TOP
SIDEREAR
PRODUCT AND CABINETRY DIMENSIONS CG301D CG451D CG752D CG903D
mm mm mm mm
AOverall height of product (excluding burners, dials and pan supports) 64 64 64 64
BOverall width of product 300 450 750 900
COverall depth of product 530 530 450 450
DHeight of chassis (below top of bench) 59 59 59 59
EWidth of chassis 256 406 706 856
FDepth of chassis 486 486 410 410
GOverall width of cutout 260 415 715 865
HOverall depth of cutout 490 490 410 410
ICorner radius of cutout max. 10 max. 10 max. 10 max. 10
JDistance from top of bench to centre of gas inlet on product 30 30 30 30
KDistance from edge of chassis to gas inlet on product 21 21 21 21
9
FRONT
ISO
CLEARANCE DIMENSIONS CG301D CG451D CG752D CG903D
mm mm mm mm
AMinimum clearance from left edge of cutout to nearest combustible surface 120 60 115 115
BMinimum clearance from right edge of cutout to nearest combustible surface 120 60 115 115
CMinimum clearance from rear edge of cutout to:
Nearest combustible surface
Nearest non-combustible surface
85
45
85
45
125
45
125
45
DMinimum height of non-combustible material when used on adjacent walls 150 150 150 150
EMinimum clearance from cooktop surface to:
Rangehood
Any other overhead exhaust fan
Downward facing combustible surface
Downwards-facing tiled or fire resistant surface
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
FMinimum clearance below top of benchtop to:
Combustible surface
Fisher & paykel oven or nearest non-combustible surface
70
65
70
65
70
65
70
65
GMinimum distance from right edge of cooktop to gas connection point on wall
(if using a flexible hose)
250 250 250 250
HDistance from floor to gas connection point on wall (if using a flexible hose) min. 800 -
max. 850 min. 800 -
max. 850 min. 800 -
max. 850 min. 800 -
max. 850
IMaximum overall depth of overhead cabinetry 600 600 600 600
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width
of the product, on the right-hand side. It should be accessible with the product installed.
5 CLEARANCE DIMENSIONS
A
I
B
C
E
H
D
F
G
A
I
B
C
E
H
D
F
G
10
A
KD
B
E
C
G
F
J
H
I
6 FLUSH MOUNTING INSTALLATION (OPTIONAL)
TOP
TOP
FRONT
REAR SIDE
A
D
B
E
C
G
G
F
K
L
HH
I J
Note: Gas inlet connection is located in the
rear right corner.
PRODUCT AND CABINETRY DIMENSIONS CG301D CG451D CG752D CG903D
mm mm mm mm
AOverall height of product (excluding burners, dials and pan supports) 64 64 64 64
BOverall width of product 300 450 750 900
COverall depth of product 530 530 450 450
DHeight of chassis (below top of bench) 59 59 59 59
EWidth of chassis 256 406 706 856
FDepth of chassis 486 486 410 410
GOverall width of routered recess 305 455 755 905
GIWidth of cutout 260 415 715 865
HOverall depth of routered recess 535 535 455 455
HIDepth of cutout 490 490 410 410
ICorner radius of cutout max. 10 max. 10 max. 10 max. 10
JCorner radius of routered recess max. 2 max. 2 max. 2 max. 2
KHeight of routered recess 5 5 5 5
LDistance from top of bench to centre of gas inlet on product 35 35 35 35
MDistance from edge of chassis to gas inlet on product 21 21 21 21
NMinimum clearance below top of benchtop to:
rear top of oven* installed below cooktop or cabinetry
thermal protection barrier
75
70
75
70
75
70
75
70
WARNING!
We do not recommend flush mounting and
sealing as servicing requires the cooktop to
be removed from the benchtop. The owner
carries all risk for flush mounting the cooktop.
The owner must ensure the cooktop has been
cut out from the benchtop before servicing
can be carried out. Fisher & Paykel will not be
liable for any costs associated with removing
or replacing a flush-mounted and/or sealed-in
product, nor for repairing any damage that
may be incurred by doing this.
!
N
ML
11
1
1
2
2
5 mm
3
min. 150 OC rated
TO REMOVE PRODUCT
x 4
16 - 50mm
6 FLUSH MOUNTING INSTALLATION (OPTIONAL)
1
1
2
2
5 mm
3
min. 150 OC rated
TO REMOVE PRODUCT
x 4
16 - 50mm
1
1
2
2
5 mm
3
min. 150 OC rated
TO REMOVE PRODUCT
x 4
16 - 50mm
min. 150 OC rated
1
1
2
2
5 mm
3
min. 150 OC rated
TO REMOVE PRODUCT
x 4
16 - 50mm
1
1
2
2
5 mm
3
min. 150 OC rated
TO REMOVE PRODUCT
x 4
16 - 50mm
Ensure silicone does not leak underneath the glass.
A ROUTER THE BENCHTOP TO THE SPECIFIED DEPTH
D APPLY SILICONE
B FIT THE CLAMPING BRACKETS
E WIPE OFF EXCESS SILICONE
C MASK OFF THE AREA TO BE SILICONED
F IF REMOVING PRODUCT, CUT
AROUND THE SILICONE
3 mm
view from below
Choose most
appropriate slot
for benchtop
thickness
12
7 DISCARD PACKAGING
9 FIT THE ELBOW AND WASHER
8 REMOVE THE TWO TRANSIT SCREWS
!0 LOWER GENTLY INTO THE CUTOUT
Nipple (½NPT thread)
Foam Tape
Adhesive side
Ensure edge of tape
lines up with outer
edge of cooktop
Recycle responsibly
Model may vary from illustrations shown
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP ½ “ BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP ½ “ BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
Repeat on the other side
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½BSP ½BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
Floating nut Elbow (1/2” BSP thread) & Washer
HONG KONG
SINGAPORE
Floating nut Fibre washer Elbow (1/2” BSP external thread)
13
!1 FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS !2 SECURE TO BENCHTOP
!3 CONNECT TO GAS SUPPLY !4 CHECK ALL CONNECTIONS FOR GAS LEAKS
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP ½ “ BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP ½ “ BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
view from below
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½BSP ½BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
Repeat on all the other sides
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP ½ “ BSP
x 4
1
1
2
2
16-20mm 20-30mm
Fibre washer
Floating nut Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm 40mm+
GAS
ON
GAS
ON
1
2
Fibre washer
Floating nut Elbow (½ BSP external thread)
Foam Tape
Adhesive side
20 mm
50 mm
+50 mm
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
regulator.
Adjust to obtain a test point
pressure of 1 kPa with all
burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 7‐1) female thread connection.
The hose assembly must be no longer than 1.2 m in length with minimum internal
diameter of 10 mm and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
recessed to 50 mm
check all connections
Make sure to t the supplied
test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with all
burners operating at highest
setting.
To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
Check for a well‐dened blue ame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact your nearest F&P Authorised Service Centre.
The cooktop must not be used by the customer until proper operation has been achieved.
yellow tiplifting o
good ame
Arrow
TG
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Adjust to obtain a supply pressure of
1.5 kPa (Hong Kong) or 0.8 kPa (Singapore)
with all the burners operating at the
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be certied, with an Rp ½” (ISO 7‐1) female thread connection.
The hose assembly must be as short as practicable and comply with relevant local code and regulation requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG
Make sure the supply pressure
is regulated to 2.90 kPa, with
all the burners operating at
highest setting.
14
INSTALLATION INSTRUCTIONS
!7 TEST OPERATION
!5 AFFIX DUPLICATE DATA LABEL SOMEWHERE
ACCESSIBLE & PLUG COOKTOP IN !6 FIT PAN SUPPORTS
Duplicate data label
Lifting off Yellow tip
Good flame
To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
Check for a well-defined blue flame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact Customer Care or your nearest F&P Authorized Service Center.
The cooktop must not be used by the customer until proper operation has been achieved.
Ensure the pan supports are
located securely
and in the correct orientation
(refer to User guide)
15
!8 FINAL CHECKLIST
TO BE COMPLETED BY THE INSTALLER
Have you installed the clamping brackets?
Have you verified that the type of model (factory-set for NG or LP) matches the type of gas at the site of installation?
Have you used the Elbow supplied?
Have you sealed all connections with gas tape?
Have you leak-tested all connections?
Is the cooktop set to the correct working pressure?
Have you affixed the supplied duplicate data plate label on an adjacent
surface accessible to the customer?
Is the cooktop earthed?
Check that the power supply cord is NOT touching the cooktop.
OPERATION:
Do all burners ignite both individually and in combination?
Are the flames consistent and appropriately sized?
Have you demonstrated the basic operation to the customer?
Complete and keep for safe reference:
Model
Serial No.
Purchase Date
Purchaser
Dealer Address
Installer’s Name
Installer’s Signature
Installation Company
Installation Date
59061G 10.21
FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2021. All rights reserved.
The models shown in this guide may not be available in all markets
and are subject to change at any time.
The product specifications in this guide apply to the specific products and
models described at the date of issue. Under our policy of continuous product
improvement, these specifications may change at any time.
For current details about model and specification availability in your country,
please go to our website or contact your local Fisher&Paykel dealer.
安裝說明書
CG301DCG451DCG752D型和CG903D
氣體煮食爐
安裝說明書
HK SG
3
1 安全警告
重要安全須知!
必須特別注意相關的通風要求。
 在安裝氣體煮食爐之前仔細閱讀本說明書。
 請讓氣體煮食爐安裝人員閱讀本說明書,因為這可以
降低安裝成本。
 氣體煮食爐只能由授權人士進行安裝和維修。
 必須按照當地的建築法規和電氣法規要求進行安裝。
 安裝不當可能會造成人身傷害或財物損失,製造商對
此不承擔任何責任,保固或責任求償自動失效。
氣體煮食爐在出廠前設定為使用液化石油氣或煤氣。
如有疑慮,請向當地供氣公司諮詢,確認安裝點供應
哪種氣體。
 切勿改動氣體煮食爐。
切勿在氣體煮食爐上或周圍使用或存放易燃物。
切勿在使用氣體煮食爐時在周圍噴氣霧劑。
在安裝過程中和安裝之後,切勿把包裝材料(例如塑
膠袋、聚苯乙烯泡沫、搭扣和包裝帶)放在氣體煮食
爐附近,尤其不能放在兒童夠得到的地方,否則可能
會造成嚴重人身傷害。
必須在安裝氣體煮食爐之前卸下固定螺絲。參看安裝
說明第8步。
警告!
觸電危險
 在處理氣體煮食爐的電氣部分之前,必須斷
開總電源。
必須連接良好接地線。
如果要改動室內佈線,必須由資深電工進行
改動。
 如不遵照此建議,可能會造成觸電甚至死
亡。
警告!
 割傷危險
 小心—面板邊沿很鋒利。
 如不小心,可能會造成人身傷害或割傷。
重要!
妥善保存本說明書
本說明書所述的型號並非在所有市場上銷售,隨時會有變動。如要詳細瞭解本國/本地區銷售的型號和規格,請登錄本指南封底列出的地區網站,或者聯絡當地的斐雪派克經銷商。
4
在安裝氣體煮食爐之前確保:
參看氣體氣速摘要一節瞭解氣體煮食爐的調節條
件。
 在永久性佈線中安裝一個符合當地佈線法規要求的
合適斷路開關。根據當地的佈線法規,安裝在固定
佈線系統裡的斷路開關的所有電極的觸點氣隙間隔
3mm,除非當地佈線法規允許採用替代方法。
 氣體煮食爐連接220V-240V 50Hz (10A)電源,並通過
電源線中的地線接地。
 氣體煮食爐旁邊有電源插座。在安裝氣體煮食爐之
後,插座所在位置必須便於使用者插拔插頭。電源
線不得接觸任何金屬零件。
 如果電源線破損,必須用斐雪派克授權維修代理商
提供的專用電源線更換:零件編號533578—Flex
子塊CN。參看維修和保固小冊子瞭解聯絡資料。
 在安裝氣體煮食爐之後,氣源接頭(氣體截流閥)
所在位置必須便於使用者開關氣體。
 灶台用耐熱材料製成。
 氣體煮食爐安裝符合國家和當地供氣公司、供電公
司的要求和其他相關法律法規的要求。
在安裝氣體煮食爐時
建議你不要採用與灶台齊平方式安裝氣體煮食爐,
不要用矽膠或膠水把氣體煮食爐固定在灶台上,否
則日後很難維修。斐雪派克不承擔與拆卸或安裝膠
粘氣體煮食爐相關的任何費用,對在此過程中可能
發生的修理損壞不承擔任何責任。
如果安裝符合法規要求的軟管,軟管不應接觸氣體
煮食爐底面或任何鋒利邊沿。軟管必須符合當地法
規要求。
 開口裸露邊沿用油漆或防水聚氨酯密封,防止濕氣
滲入氣體煮食爐邊沿和灶台之間。
 在安裝過程中切勿讓玻璃表面破碎、開裂或破裂。
重金屬工具或零件不慎跌落在玻璃上可能會損壞玻
璃。
 如果在根據氣體煮食爐安裝說明安裝之後,氣體煮
食爐達不到要求的性能,請聯絡客戶服務部,或者
登錄本指南封底列出的地區網站聯絡我們。
1 安全警告
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32