Technical specifications
The following specifications are only those required by law to ship with your system. For a complete and current listing of the
specifications for your system, see Dell.com/dssmanuals.
Power:
2000 W Platinum AC 100–240 V, 50/60 Hz, 12 A–10 A
NOTE: If the system operates at a low line voltage, then the power rating per PSU is derated. The power derating information
for 2000 W PSU is listed in the following table.
Low line voltages Derated wattage
100–120 V AC 1000 W
200–205 V AC 1750 W
205–220 V AC 1850 W
220–230 V AC 1950 W
230–240 V AC 2000 W
System battery: 3 V CR2032 lithium coin cell
Temperature: Maximum ambient temperature for continuous operation: 35°C/95°F
NOTE: Certain system configurations may require a reduction in the maximum ambient temperature limit. The performance of
the system may be impacted when operating above the maximum ambient temperature limit or with a faulty fan.
For information on Dell Fresh Air and supported expanded operating temperature range, see the Installation and Service Manual at
Dell.com/dssmanuals.
技术规格
以下仅是依照法律规定随系统附带的规格。有关系统规格的当前完整列表,请参阅 Dell.com/dssmanuals。
电源:
2000 W 白金 AC 100–240 V,50/60 Hz,12 A–10 A
注:如果系统以低电压运行,则每个 PSU 的额定功率将会降低。下表列出了 2000 W PSU 的功率降额信息。
低电压 降额功率
100–120 V AC 1000 W
200-205 V AC 1750 W
205-220 V AC 1850 W
220-230 V AC 1950 W
230-240 V AC 2000 W
系统电池:3 V CR2032 币形锂电池
温度:持续运行的最高环境温度:35°C/95°F
注:某些系统配置可能需要降低最高环境温度极限。若在最高环境温度极限以上的温度下工作或风扇出现故障,系统的性能
可能会受到影响。
有关 Dell Fresh Air 以及支持的扩展工作温度范围的详细信息,请参阅 Dell.com/dssmanuals 中的安装和服务手册。
Spesifikasi teknis
Spesifikasi berikut ini hanya yang dipersyaratkan oleh undang-undang untuk dikirimkan bersama sistem Anda. Untuk mengetahui daftar
spesifikasi lengkap dan terbaru untuk sistem Anda, lihat Dell.com/dssmanuals.
Daya:
2000 W Platinum AC 100–240 V, 50/60 Hz, 12 A–10 A
CATATAN: Jika sistem beroperasi pada tegangan rendah, maka nilai daya per PSU diturunkan. Informasi penurunan daya untuk
2000 W PSU tercantum dalam tabel berikut.
Tegangan jalur rendah Watt yang diturunkan
100–120 V AC 1000 W
200-205 V AC 1750 W
205-220 V AC 1850 W
220-230 V AC 1950 W
230-240 V AC 2000 W
Baterai sistem: Sel litium 3 V CR2032 berbentuk koin
Suhu: Suhu ruangan maksimum untuk pengoperasian terus menerus adalah: 35°C/95°F
CATATAN: Konfigurasi sistem tertentu dapat memerlukan pengurangan dalam batas suhu ruangan maksimum. Kinerja sistem
dapat terpengaruh ketika mengoperasikan di atas batas suhu ruangan maksimum atau dengan kipas yang rusak.
Untuk informasi tentang Dell Fresh Air serta konfigurasi dan kisaran suhu pengoperasian diperpanjang yang didukung, lihat Manual
Pemilik di Dell.com/dssmanuals.
Dell.com/dssmanuals
2000 WPlatinumAC 100 240 V 50/60 Hz12 A 10 A
PSU 2000 W PSU
AC 100 120 V 1000 W
AC 200 205 V 1750 W
AC 205 220 V 1850 W
AC 220 230 V 1950 W
AC 230 240 V 2000 W
3 V CR2032
35C95F
Dell Fresh Air Dell.com/dssmanuals
WARNING: A WARNING indicates a potential for
property damage, personal injury, or death.
CAUTION: A CAUTION indicates potential damage to
hardware or loss of data if instructions are not followed.
NOTE: A NOTE indicates important information that helps
you make better use of your computer.
警告:“警告”表示可能会导致财产损失、人身伤害甚至死
亡。
小心:“小心”表示如果不遵循说明,就有可能损坏硬件或
导致数据丢失。
注:“注”表示可以帮助您更好地使用计算机的重要信息。
PERINGATAN: Sebuah PERINGATAN mengindikasikan
potensi kerusakan properti, cedera diri, atau kematian.
PERHATIAN: Sebuah PERHATIAN mengindikasikan
potensi kerusakan terhadap perangkat keras atau
kehilangan data jika petunjuk tidak diikuti.
CATATAN: CATATAN menunjukkan informasi penting yang
akan membantu Anda mengoptimalkan penggunaan komputer.
경고: "경고"는 재산상의 피해나 심각한 부상 또는 사망을
유발할 수 있는 위험이 있음을 알려줍니다.
주의: "주의"는 지침을 준수하지 않을 경우의 하드웨어
손상이나 데이터 손실 위험을 설명합니다.
주: "주"는 컴퓨터를 보다 효율적으로 사용하는 데 도움을
주는 중요 정보를 알려줍니다.
Dell End User License Agreement
Before using your system, read the Dell Software License
Agreement that is shipped with your system. If you do not accept
the terms of agreement, see Dell.com/contactdell.
Dell 最终用户许可协议
使用系统前如果您不接受协议条款,请访问
Dell.com/contactdell
Dell Perjanjian Lisensi Pengguna Akhir
Sebelum menggunakan sistem Anda, bacalah Perjanjian Lisensi
Perangkat Lunak Dell yang dikirimkan bersama sistem Anda. Jika
Anda tidak menerima pesyaratan dari perjanjian tersebut, lihat
Dell.com/contactdell.
Dell
Dell
Dell.com/contactdell
Dell 최종 사용자 사용권 계약
시스템을 사용하기 전에 시스템과 함께 제공된 Dell 소프트웨어
사용권 계약을 읽어 보시기 바랍니다. 계약의 약관에 동의하지
않을 경우, Dell.com/contactdell 을 참조하십시오.
Regulatory model/type
管制型号/类型 | Model/jenis regulasi
/ | 규정 모델/유형
B11S/B11S001, B01E/B01E001, B08B/B08B002, B09B/B09B002, and B11B/B11B002
P/N 2H2HF Rev. A00
© 2017 Dell Inc. or its subsidiaries.
2017-07
기술 사양
다음은 현지 법률에 따라 시스템과 함께 제공되어야 하는 사양입니다. 사용 중인 시스템의 최신 전체 사양 목록은
Dell.com/dssmanuals에서 볼 수 있습니다.
전원:
2000W 플래티넘 AC 100~240V, 50/60Hz, 12A~10A
주: 시스템이 로우라인 전압에서 작동하는 경우 PSU당 정격 전원은 낮아집니다. 2000W PSU의 전원 정격 감소 정보는 다음
표에 나와 있습니다.
로우라인 전압 정격 감소된 와트
100~120 V AC 1000W
200~205V AC 1750W
205~220V AC 1850W
220~230V AC 1950W
230~240V AC 2000W
시스템 배터리: 3V CR2032 리튬 코인 셀
온도: 연속 작동 시 주변 최대 온도는 35°C/95°F 입니다.
주: 일부 시스템 구성은 최대 온도 제한 수준을 감소해야 할 수도 있습니다. 최대 온도 한도를 초과하거나 결함이 있는
팬으로 작동 시 시스템 성능이 저하될 수 있습니다.
Dell Fresh Air와 지원되는 작동 온도의 범위에 관한 정보는 Dell.com/dssmanuals 의 설치 및 서비스 설명서를 참조하십시오.
本產品符合臺灣 RoHS 標準 CNS15663
單元
限用物質及其化學符號
鉛
(Pb)
汞
(Hg)
鎘
(Cd)
六價鉻
(Cr
+6
)
多溴聯苯
(PBB)
多溴二苯醚
(PBDE)
機箱/檔板 – o o o o o
機械部件
(風扇、散熱器等)
– o o o o o
電路板組件 – o o o o o
電線/連接器 – o o o o o
電源設備 – o o o o o
儲存裝置
(硬碟、光碟機等)
– o o o o o
輸入裝置
(鍵盤、滑鼠等)
– o o o o o
喇叭/麥克風 – o o o o o
配件 – o o o o o
備考 1. “o” 係指該項限用物質之百分比含量未超出百分比含量基準値。
備考 2. “–” 係指該項限用物質為排除項目。