6
14 15
26262626
8. Remote indicator
This indicator blinks when remote controller works.
The indicator will flash slowly if the battery is empty,
please change the remote controller battery in this case.
The battery model is CR2032 lithium cell.
10. Paring a new remote controller
The remote controller and main unit is 1 to 1 paired for
factory default. It’s possible to pair maximum 5 remote
controllers to one main unit and each remote controller
could be paired to any main unit.
You could pair a new remote controller to main unit by
following steps:
1). Plug off the power of main unit and plug in again
after more than 5 seconds.
2). Press and key simultaneously for about 3
seconds, within time of 10 seconds after the main unit
powered on.
9. Using the remote
Please pull out the battery insulate tape before using.
The RF wireless remote signal can pass through some
nonmetal barrier. For proper receiving remote signal,
please do not install the controller in closed metal parts.
11. Recognize current remote only
In some cases, one main unit might be paired with
several remote controllers but extra remote controllers are
no longer needed. User could simply pair the current
using remote to main unit again, then the main unit will
dis-pair all other remote controllers and recognize current
one only.
Advanced features
12. Waterproof (-S version)
The IP-68 waterproof feature with glue injection
finish is available on -S version controllers. For overall
waterproof performance, the cables must be waterproof
treated separately.
Wireless signal degrade : The wireless communication
ability could degrade when using at wet environment,
please be aware that the wireless control distance will be
shortened in such case.
13. Protection function
The controller has full protection function against
wrong wiring, load short circuit, overload and overheat.
The controller will stop working and the indicator will
flash with red / yellow color to indicate the malfunction.
The controller will try to recover from protection status
in a short time when the working condition is good.
For protection issues, please check the situation
with different indicator information:
Red flash: Check the output cables and load, make
sure no short circuit and the load current is in rated
range. Also the load must be constant voltage type.
Yellow flash: Check the installation environment,
make sure in a rated temperature range and with good
ventilation or heat dissipation condition.
Operation