LILIN IM1520 Supported models : IM15208, IM15458, IM15608 インストールガイド

タイプ
インストールガイド
Part Description & Dimensions
D/N HD IR IP CAMERA
66-1520CSB-1
Installation Guide
Unit: mm
Installation
1. Attach the illuminator bracket to the pan and tilt unit, ceiling mount (FIG.1)
or wall mount (FIG.2).
FIG.1 FIG.2
2. Connect the power cable to AC100~240V (FIG.3).
Note: If used power cable is like two wire combine, please put them
separately on “Live” and “Neutral.
Earth
Neutral
Live
Green/Yellow
Blue
Brown
FIG.3
3-1. If want to adopt ICR (IR Cut Filter Removable) of Day&Night camera to
reach synchronization action with illuminator, please connect the Day/
Night output cable to input of the camera. The Green wire connect to “,
and Black wire connect to “(GND). IR illuminator will be triggered “Off
with 5V output voltage and IR illuminator will be triggered “On” with 0V
output voltage.
3-2. If you want to externally control the device infrared synchronization,
please connect the external signal source to the device '+' terminal blue
wire and the '-' terminal to the gray wire (GND)."
" "
FIG.4
Corresponding hardware switch setting
Remove the back cover by unscrewing the four screws (FIG.5) and
switch the day/night, high and low position according to external control,
adjust the settings as follows (FIG.6&7):
FIG.5 FIG.6
SW1
SW2
Note: For the security, if not used Day/Night input/output, please use the
adhesive tape to wrap the connections.
FIG.11FIG.10
6. To adjust light sensor sensitivity, first remove the sealing cap. Then adjust
the potentiometer to turn the IR illuminator on when the lighting conditions
are lighter or darker. Adjust further clockwise to make the IR illuminator
turn on when it’s lighter and counterclockwise when its darker.
FIG.12
Note1: To disable the light sensor adjust the sensitivity fully clockwise.
This should make the IR illuminator turn on all the time.
Note2: Once all adjustments have been carried out, make sure that the
sealing caps are properly closed so as to ensure the hermetic
seal of the product.
102.5
73
132
192.5
6
5
4
3
2
7
172
165
242
1
GrayGND
BlueDN IN
BlackGND
GreenDN OUT
WhiteN.O
YellowCOM
RedN.C
177
186.5
ψ9.5 8
80
Light Sensor
Bracket
Power Cable
Day and night input/output signal control cable and device status interface.
Bottom Chassis
Front Fascia
Rear Cover
Sealing Cap (Light Sensor Sensitivity Adjust)
1
2
3
5
6
7
4
8
FIG.7
SW1 SW2
SW1
OUT
OUT HI
HI
IN
IN LOW
LOW
Day/Night Output Synchronization Mode
(Factory Default)
External input control
mode
External Control HI Activates
IR ONHI (+3V~+5V)
IR OFFLOW (0V)
External Control LOW Activates
IR ONLOW (0V)
IR OFFHI (+3V~+5V)
3-3. Device Status Relay Operation Mode:
When the device is operating normally, the status of the Relay output
interface.
Red wire
Yellow wire
White wire
Device status RELAY
When the device is powered off or not in operation, the status of the
Relay output interface.
Red wire
Yellow wire
White wire
Device status RELAY
4. Adjust the horizontal alignment by loosening the bracket bolts to match the
camera field of view (FIG.8&9).
FIG.9FIG.8
5. Adjust the vertical alignment by loosening the side bolts (one on each side
of the main body) to maximize the results (FIG.10&11).
紅 外 線 夜 視 器
警語: 此,指廢棄品時直接棄垃
圾桶進行解,分類回收利用
件說明及尺寸
裝說
mm
102.5
73
132
192.5
6
5
4
3
2
7
172
165
242
1
177
186.5
ψ9.5 8
80
前面板
封蓋
線開調
5
6
7
8
1
1. 架可調掛安1&2
2. 電連接AC100~240V 電源 3
使用接在"火線"及"中線"。
圖 )
接地
中性
火線
綠線
白線
黑線
2
3
3-1. 如想ICRIR Cut Filter Removable
機的日/夜纜線
入端 線接到 - 端(
線關5V啟時
0V
" "
3-2. 如想步動
端藍色線連接,-端接到灰色線(接地端)
" "
4
了安使出電
接點
體開
蓋45換日/夜
調整設6&7
56
SW1
SW2
7
SW1 SW2
SW1
OUT
OUT HI
HI
IN
IN LOW
LOW
日/夜輸模式
(出
外部制模HI
IR ONHI(+3V~+5V
IR OFFLOW0V
外部LOW
IR ONLOW0V
IR OFFHI(+3V~+5V
4. 轉鬆腳架螺絲,調整紅外線投射器的水平方向到所需的攝影角
8&9)。
98
5. 轉鬆紅外線投射器兩側的螺絲,調整其垂直方向到所需的攝影
10&11
入/出訊
狀態
1
2
3
4
把可此時
會永
當完調確保
個防
12
1110
6. 掉防調到所
。往照度
轉動12
灰:GND
藍:DN IN
黑:GND
綠:DN OUT
白:N.O
黃:COM
紅:N.C
3-3. 設備Relay作動形式:
正常Relay
紅線
黃線
白線
設備RELAY
斷電Relay
紅線
黃線
白線
設備RELAY
  • Page 1 1
  • Page 2 2

LILIN IM1520 Supported models : IM15208, IM15458, IM15608 インストールガイド

タイプ
インストールガイド