将传感器主体固定在安装位置,将表带绕过安装母排或者触头穿过表带,表带头收紧,最后将
表带尾用锁扣锁紧。表带过长可以剪掉多余部分,表带过短可以联系我司增订。安装前打开电池开
关,电源指示灯闪烁两次。安装实例见下图:
注:ATE200 可安装静触头,铜排,电缆头。
Fixing the body of sensor on the position, then strapping it on the bus bar or breaker contact and
frapping it through the hole on the strap, fixing the strap by hasp. Clipping the strap if it is too long when
finished, if it is too short, contacting us for strap parts before installation. Open the battery switch before
installation, the power indicator flashes twice.The installation examples see images below.
Note: ATE200 can be installed with fixed contact, copper plate and cable head.
1.4.3.4 ATE400 安装方法
1.4.3.4 ATE400 Installation Method
ATE400 迷你型无线温度传感器适用于静触头,母排,电缆,母排、电缆搭接处等多种场合。
The mini type called ATE400 is suitable for using at moving contacts, bus bars, cables and joints
between bus bar and cable.
迷你型无源无线温度传感器结构说明:
Mini type passive temperature sensor structure introduction:
1 —— 温度传感器主体 The core of wireless temperature sensor ATE400
2 —— 合金底座,与温度探头接触 alloy bottom, touched with temperature probe
3 —— 锁扣,用于固定合金片 metal hasp, for fixing alloy chip
4 —— 取电合金片,用于感应取电 alloy chip, for CT-powered
5 —— 硅胶垫片,用于支撑合金片 silicone gasket, used to support the alloy chip
6 —— 合金片安装孔,用于安装合金片 alloy chip hole, used to install the alloy chip