Part Description & Dimensions
D/N HD IR IP CAMERA
66-1520CSB-2
Installation Guide
Unit: mm
Installation
1. Attach the illuminator bracket to the pan and tilt unit, ceiling mount (FIG.1)
or wall mount (FIG.2).
FIG.1 FIG.2
2. Connect the power cable to AC100~240V (FIG.3).
Note: If used power cable is like two wire combine, please put them
separately on “Live” and “Neutral”.
Earth
Neutral
Live
Green/Yellow
Blue
Brown
FIG.3
3-1. If want to adopt ICR (IR Cut Filter Removable) of Day&Night camera to
reach synchronization action with illuminator, please connect the Day/
Night output cable to input of the camera. The Green wire connect to “+”,
and Black wire connect to “—”(GND). IR illuminator will be triggered “Off”
with 5V output voltage and IR illuminator will be triggered “On” with 0V
output voltage.
3-2. If you want to externally control the device infrared synchronization,
please connect the external signal source to the device '+' terminal blue
wire and the '-' terminal to the gray wire (GND)."
" "+
"—"
FIG.4
Corresponding hardware switch setting
Remove the back cover by unscrewing the four screws (FIG.5) and
switch the day/night, high and low position according to external control,
adjust the settings as follows (FIG.6&7):
FIG.5 FIG.6
SW1
SW2
Note: For the security, if not used Day/Night input/output, please use the
adhesive tape to wrap the connections.
FIG.11FIG.10
6. To adjust light sensor sensitivity, first remove the sealing cap. Then adjust
the potentiometer to turn the IR illuminator on when the lighting conditions
are lighter or darker. Adjust further clockwise to make the IR illuminator
turn on when it’s lighter and counterclockwise when it’s darker.
FIG.12
Note1: To disable the light sensor adjust the sensitivity fully clockwise.
This should make the IR illuminator turn on all the time.
Note2: Once all adjustments have been carried out, make sure that the
sealing caps are properly closed so as to ensure the hermetic
seal of the product.
102.5
73
132
192.5
6
5
4
3
2
7
172
165
242
1
Gray:GND
Blue:DN IN
Black:GND
Green:DN OUT
White:N.O
Yellow:COM
Red:N.C
177
186.5
ψ9.5 8
80
Light Sensor
Bracket
Day and night input/output signal control cable and device status interface.
Bottom Chassis
Front Fascia
Rear Cover
Sealing Cap (Light Sensor Sensitivity Adjust)
Power Cable
1
2
3
5
6
7
4
8
FIG.7
SW1 SW2
SW1
OUT
OUT HI
HI
IN
IN LOW
LOW
Day/Night Output Synchronization Mode
(Factory Default)
External input control
mode
External Control HI Activates
IR ON:HI (+3V~+5V)
IR OFF:LOW (0V)
External Control LOW Activates
IR ON:LOW (0V)
IR OFF:HI (+3V~+5V)
3-3. Device Status Relay Operation Mode:
When the device is operating normally, the status of the Relay output
interface.
Red wire
Yellow wire
White wire
Device status RELAY
When the device is powered off or not in operation, the status of the
Relay output interface.
Red wire
Yellow wire
White wire
Device status RELAY
4. Adjust the horizontal alignment by loosening the bracket bolts to match the
camera field of view (FIG.8&9).
FIG.9FIG.8
5. Adjust the vertical alignment by loosening the side bolts (one on each side
of the main body) to maximize the results (FIG.10&11).