Sony SEL-2470Z 取扱説明書

カテゴリー
カメラレンズ
タイプ
取扱説明書

このマニュアルも適しています

–1
(1) (2)
–2
FE 4/24-70
FE 4/24-70
2
1
6
7
3
4 5
FE 4 / 24- 70
E A
Vario-Tessar T FE 24-70mm F4 ZA OSS
E
35mm
35mm
APS-C
http://www.sony.co.jp/DSLR/support/
1
2
1
2
3
4
5
6 *
7
*
1
1 2 2
2
2
3
DMF
Vario-Tessar T
FE 24-70mm F4 ZA OSS
(SEL2470Z)
35mm *
1
mm
36-105
10-12
1*
2
84°-34°
2*
2
61°-23°
*
3
m
0.4
0.2
F22
mm
67
mm
73×94.5
g
426
*
1
35mm APS-C
*
2
1 35mm 2 APS-C
*
3
1 1
1 1
1
This instruction manual explains how to use lenses.
Precautions common to all lenses such as notes on use
are found in the separate “Precautions before using”. Be
sure to read both documents before using your lens.
This lens is designed for E-mount cameras. You cannot use
it on A-mount cameras.
The Vario-Tessar T FE 24-70mm F4 ZA OSS was
developed jointly by Carl Zeiss and Sony Corporation and
designed for Sony E-mount cameras. This lens is produced
under the strict standards and quality assurance system of
Carl Zeiss.
The Vario-Tessar T FE 24-70mm F4 ZA OSS is
compatible with the range of a 35mm format image sensor.
A camera equipped with a 35mm format image sensor can
be set to shoot at APS-C size.
For details on how to set your camera, refer to its
instruction manual.
For further information on compatibility, visit the Sony
web site in your area, or consult your Sony dealer or local
authorized Sony service facility.
Notes on Use
When carrying a camera with the lens attached, always firmly
hold both the camera and the lens.
Do not hold by the part of the lens that protrudes when
zooming.
This lens is not water-proof, although designed with dust-
proofness and splash-proofness in mind. If using in the rain
etc., keep water drops away from the lens.
Precautions on using a flash
When using a flash, always remove the lens hood and shoot
at least 1 m (3.3 feet) away from your subject. With certain
combinations of lens and flash, the lens may partially block
the light of the flash, resulting in a shadow at the bottom of
the picture.
Vignetting
When using the lens, the corners of the screen become darker
than the center. To reduce this phenomena (called vignetting),
close the aperture by 1 to 2 stops.
Identifying the Parts
1 Lens hood index
2 Focusing ring
3 Zooming ring
4 Focal-length scale
5 Focal-length index
6 Lens contacts*
7 Mounting index
* Do not touch the lens contacts.
Attaching and Detaching the Lens
To attach the lens
(See illustration
.)
1
R
emove the rear and front lens caps and the
camera body cap.
You can attach/detach the front lens cap in two ways, (1)
and (2). When you attach/detach the lens cap with the
lens hood attached, use method (2).
2
Align the white index on the lens barrel with
the white index on the camera (mounting
index), then insert the lens into the camera
mount and rotate it clockwise until it locks.
Do not press the lens release button on the camera when
mounting the lens.
Do not mount the lens at an angle.
To remove the lens
(See illustration
.)
While holding down the lens release button on
the camera, rotate the lens counterclockwise
until it stops, then detach the lens.
Attaching the Lens Hood
It is recommended that you use a lens hood to reduce flare
and ensure maximum image quality.
Align the red line on the lens hood with the red
dot on the lens (lens hood index), then insert
the lens hood into the lens mount and rotate it
clockwise until it clicks into place and the red
dot on the lens hood is aligned with the red dot
on the lens.
When using a built-in camera flash or an external flash
attached to the camera, remove the lens hood to avoid
blocking the flash light.
When storing, fit the lens hood onto the lens backwards.
Zooming
Rotate the zooming ring to the desired focal
length.
Focusing
There are three ways to focus.
Auto focus
The camera focuses automatically.
DMF (Direct manual focus)
After the camera focuses in auto focus, you can make a fine
adjustment manually.
Manual focus
You focus manually.
For details on mode settings, refer to the instruction manual
supplied with the camera.
Specifications
Product name
(Model name)
Vario-Tessar T
FE 24-70mm F4 ZA OSS
(SEL2470Z)
Equivalent 35mm-format focal
length*
1
(mm)
36-105
Lens groups-elements
10-12
Angle of view 1*
2
84°-34°
Angle of view 2*
2
61°-23°
Minimum focus*
3
(m (feet))
0.4 (1.32)
Maximum magnification (X)
0.2
Minimum aperture
f/22
Filter diameter (mm)
67
4-528-706-01(1)
©2013 Sony Corporation
SEL2470Z
Interchangeable Lens
Objectif interchangeable
Operating Instructions
Mode d’emploi
Manual de instrucciones
Vario-Tessar T
FE 24-70mm F4 ZA OSS
E-mount
Printed in Thailand
Product name
(Model name)
Vario-Tessar T
FE 24-70mm F4 ZA OSS
(SEL2470Z)
Dimensions (maximum
diameter × height)
(approx., mm (in.))
73 × 94.5
(2 7/8 × 3 3/4)
Mass (approx., g (oz))
426 (15.1)
Shake compensation function
Yes
*
1
The values shown above for equivalent 35mm-format
focal length are for Interchangeable Lens Digital Cameras
equipped with an APS-C sized image sensor.
*
2
Angle of view 1 is the value for 35mm cameras, and angle of
view 2 is the value for Interchangeable Lens Digital Cameras
equipped with an APS-C sized image sensor.
*
3
Minimum focus is the distance from the image sensor to the
subject.
Depending on the lens mechanism, the focal length may
change with any change in shooting distance. The focal
lengths given above assume the lens is focused at infinity.
Included items
Lens (1), Front lens cap (1), Rear lens cap (1),
Lens hood (1), Lens case (1), Set of printed documentation
Design and specifications are subject to change without
notice.
is a trademark of Sony Corporation.
Cette notice explique comment se servir des objectifs.
Les précautions communes à tous les objectifs, par
exemple les remarques sur l’emploi, se trouvent sur la
feuille « Précautions avant toute utilisation ». Veuillez
lire les deux documents avant d’utiliser votre objectif.
Cet objectif est conçu pour les appareils photo à monture E.
Il ne peut pas être utilisé pour les appareils photo à monture
A.
Le Vario-Tessar T
FE 24-70mm F4 ZA OSS qui a
été développé en collaboration par Carl Zeiss et Sony
Corporation est destiné aux appareils photo à monture E de
Sony. Cet objectif a été fabriqué selon les normes strictes et
le système d’assurance qualité de Carl Zeiss.
Le Vario-Tessar T FE 24-70 mm F4 ZA OSS est
compatible avec la plage d’un capteur d’image de format
35 mm. Un appareil photo équipé d’un capteur d’image de
format 35 mm peut être réglé pour la prise de vue en APS-C.
Pour les détails sur la manière de régler l’appareil photo,
reportez-vous à son mode d’emploi.
Pour plus d’informations sur la compatibilité, consultez le site
de Sony de votre pays, ou adressez-vous à un revendeur Sony ou
à un service après-vente agréé Sony.
Remarques sur l’emploi
Lorsque vous portez un appareil photo avec l’objectif dessus,
tenez toujours fermement l’appareil photo et l’objectif.
Ne tenez pas l’appareil photo par la partie de l’objectif qui
ressort lors d’un zoom.
Cet objectif n’est pas étanche à l’eau bien qu’il soit conçu pour
résister à la poussière et aux éclaboussures. Si vous l’utilisez
sous la pluie, etc. veillez à ce que de l’eau ne tombe pas dessus.
Précautions concernant l’emploi d’un flash
Lorsque vous utilisez un flash, retirez toujours le parasoleil et
prenez vos photos à au moins 1 m (3,3 pieds) du sujet. Associé
à certains types de flash, l’objectif peut bloquer partiellement
la lumière du flash et produire un ombre au bas de l’image.
Vignetage
Lorsque l’objectif est utilisé, les coins de l’écran deviennent
plus sombres que le centre. Pour réduire ce phénomène
(appelé vignetage), fermez l’ouverture de 1 ou 2 crans.
Identification des éléments
1 Repère de parasoleil
2 Bague de mise au point
3 Bague de zoom
4 Échelle de focale
5 Repère de focale
6 Contacts d’objectif*
7 Repère de montage
* Ne touchez pas les contacts d’objectif.
Pose et dépose de l’objectif
Pour poser l’objectif
(Voir l’illustration .)
1
Déposez les capuchons d’objectif avant et
arrière et le capuchon de l’appareil photo.
Vous pouvez poser et déposer les capuchons d’objectif
avant de deux façons, (1) et (2). Si vous posez/déposez le
capuchon d’objectif avec le parasoleil, utilisez la méthode
(2).
2
Alignez le repère blanc du barillet d’objectif
sur le repère blanc de l’appareil photo
(repère de montage), puis posez l’objectif
sur la monture de l’appareil photo et
tournez-le dans le sens horaire de sorte qu’il
s’encliquette.
N’appuyez pas sur le bouton de libération de l’objectif sur
l’appareil photo lorsque vous posez l’objectif.
Ne posez pas l’objectif de biais.
Pour déposer l’objectif
(Voir l’illustration .)
Tout en appuyant sur le bouton de libération de
l’objectif sur l’appareil photo, tournez l’objectif
dans le sens antihoraire jusqu’à l’arrêt, puis
déposez l’objectif.
(Suite à la page arrière)
  • Page 1 1
  • Page 2 2

Sony SEL-2470Z 取扱説明書

カテゴリー
カメラレンズ
タイプ
取扱説明書
このマニュアルも適しています