[FIG.11]
Part Description & Dimensions
IR Fast Dome IP CAMERA
66-5728CSB-1
Installation Guide
ø184
184mm
368mm
Camera bracket
Camera bracket base
Camera quick release adaptor
Camera body
LED Indicators
Green (STATUS): Indicates system status.
Green (LINK): Illuminates when the camera is connected
to a network.
Orange (ACT): Flashes when data communication is in process.
Service Key: Restores the camera back to factory default settings.
Micro SD Card Slot
AC100~240V Power Cable
AC24V Power Cable
DC48V Power Cable
RJ-45 Network Cable
Alarm Out CableAlarm Output: DC40V, 300mA max.
Alarm In Cable (Alarm Input Voltage: 5.6V max)
Video Out BNC Jack
Video Signal Output CVBS 1.0Vp-p 75 BNC
Audio In/Out Cable & RS-485 -/+ Cable
Audio: 1.98Vp-p max.
Ω
8
9
10
11
12
13
14
15
1
2
3
4
56
7
1
2
3
4
5
6
7
DC48V()
N/A
DC48V( - )
AC24V(L)
GND
AC24V(N)
ALARM OUT 1
COM 1
ALARM OUT 2
COM 2
ALARM IN 1
ALARM IN 2
ALARM IN 3
ALARM IN 4
GND
AUDIO IN
GND
AUDIO OUT
RS-485 -
RS-485+
8
9
10
11
12
13
14
15
Installation
Step 1 Remove the bracket from the base
Loosen the four bolts from the base (FIG.1) and push the hinge upwards to
separate it from the base (FIG.2).
[FIG.1] [FIG.2]
Step 2 Secure the bracket base to the wall
Attach the installation sticker to the wall and drill four holes according to the
instructions (FIG.3). Tighten four bolts to secure the base to the wall (FIG. 4).
To use the central hole on the base, first hammer the lid off (FIG.5).
Note:
1. The recommended length of the wall-mounted screw is 1.5"(38.1mm) or more
2. The bolts are not included in the package.
CAU TIO NCAU TIO N
PLEASE USE
5/16" OR M8
EXPANSION BOLT.
請搭配使用
膨脹螺栓。
5/16" M8
60mm
[FIG.3] [FIG.4] [FIG.5]
60mm
CAUTION
PLEASE USE
5/16" OR M8
EXPANSION BOLT.
請搭配使用
膨脹螺栓。
5/16" M8
Step 3 Attach the quick release adaptor to the bracket
First remove the quick release adaptor from the camera body. Align the adaptor
with the bracket before tightening the bracket bolts (FIG. 6 & FIG.7). Then slide
the adaptor and bracket together down the hinge to connect to the base (FIG.8).
Note: The four bolts on the adaptor must be loosened first to remove the
adaptor.
[FIG.8]
[FIG.7][FIG.6]
Step 4 Secure the safety strap
To prevent the camera from falling, you should first secure the safety strap.
Properly secure the safety strap to the bracket, and slip the safety strap through
the bracket (FIG.9 & FIG.10). Secure the safety strap to the camera body
(FIG.11).
[FIG.10][FIG.9]
Step 5 Slip the control wires through the bracket
Slip the control wires through the bracket (FIG.12). Align markings on the quick
release adaptor and the camera body. Twist the camera body clockwise into
to adaptor (FIG.13). Tighten the four bolts on the adaptor to secure the camera
body (FIG.14) .
[FIG.12]
Step 6 Connect the control wires
Connect the AC power connector, RJ-45 cable and control wire (FIG.15). Secure
the bracket to the base (FIG.16) and finish the installation (FIG.17).
[FIG.16][FIG.15]
AC100~240V
AC24V
Vid eo Signal
RJ-45
DC48V
Alarm Out
Alarm In
Audio & RS-485
adjusted according to the instructions provided with the actual junction box.
Note: The above procedure is the recommended installation method, and can be
Before accessing the IP camera, make sure that the camera's RJ-45
network, audio, and power cables are properly connected. To set the IP
address, consult your network administrator for an available IP address.
The default IP address for each IP camera is 192.168.0.200. Users can use
the default IP address for verifying the camera's network connection.
Before Accessing IP Cameras
Emergency Factory Default
To change the settings of the IP address, subnet mask, gateway, or HTTP
port, you can follow the steps below:
1. Run the IPScan software.
2. Click Refresh. All available devices should be listed in the device list.
3. Select your device from the list provided.
4. Change the IP address, subnet mask, gateway, or HTTP port for the IP
camera.
5. Click Apply to submit the settings.
6. Click Refresh to verify the settings.
Configuring IP Addresses with IPScan Software
Login
The factory default username and password are empty. To login to the Full
HD IP camera, please set the username and password on the login page.
Press [Login] to complete the setting and login simultaneously.
Password have to meet the following criteria:
1. More than or equal to 8 characters.
2. Allow uppercase letter, lowercase letter, number digit, and special
character.
3. Must have at least three types of character sets.
IPCAM
To restore the hardware to factory default settings, please follow these
steps:
1.Press and hold “SERVICE Key” for 10 seconds and release.
2.Wait for about 40 seconds, and the network LED light should turn off,
and go back on again.
3.The camera is now restored to factory default settings, and will reboot
automatically.
4.Search for the IP device using the IPScan software.
5.Start the IP device via an Internet browser.
6.Enter the username and password to operate.
The factory default username and password are empty, and the
user can set an account for login.
The IP address will revert to the default setting of 192.168.0.200.
NOTE1:
NOTE2:
To change an IP address via web interface, type the default IP address
(192.168.0.200) in the Internet browser and follow the steps below:
1. Login to the Full HD IP camera with the set username and password.
2. Click Basic Mode configuration hyperlink.
3. Click Network->General hyperlink.
4. Change the IP address, subnet mask, gateway, or HTTP port for the
IP camera.
5. Click Submit to verify the settings.
Configuring IP Addresses via Web Interface
Universal ActiveX software components are required for web interface
display of JPEG or Full HD video. When you login to the IP camera by
Internet Explorer, the security warning dialog box will prompt the
installation of the Universal ActiveX. Click Install to download it.
Software Requirements
[FIG.13] [FIG.14]
[FIG.17]
紅外線高速球型網路攝影機
警語: 此示,指在棄產品時可直接丟
圾桶應進行拆,並分類行回收再用。
裝說
件說明及尺寸
1
2
3
4
5
6
球型攝影機支架底座
球型攝影機快拆轉盤
球型攝影機主體
AC100~240V交流電纜
AC24V電源端子
DC48V電源端子
RJ-45網路連接端子
警報輸出端子(警報輸出規格DC40V, 300mA max.
警報輸入端子(警報輸入點電壓5.6Vmax
影像輸出端子(Video Out
影像信號輸出 CVBS 1.0Vp-p 75 BNC
音輸入/輸子 & RS-485連接端子
Audio In/Out & RS-485 -/+
聲音信號:1.98Vp-p max.
球型攝影機支架
指示燈
綠色(STATUS燈號):系統狀態顯示
綠色(LINK燈號):網路線接上時,此LED恆亮。
橙色(ACT燈號):資料通訊時,此LED閃爍。
恢復出廠預設值按鍵
Micro SD卡插槽:支援Micro SDSDHC
Ω
7
DC48V()
N/A
DC48V( - )
AC24V(L)
GND
AC24V(N)
ALARM OUT 1
COM 1
ALARM OUT 2
COM 2
ALARM IN 1
ALARM IN 2
ALARM IN 3
ALARM IN 4
GND
AUDIO IN
GND
AUDIO OUT
RS-485 -
RS-485+
8
9
10
11
12
13
14
15
架底(圖2
1 將支架底
4螺絲底座1),再將支架由門栓處往上推與
[圖1] [圖2]
將安貼紙牆上之位孔(3
架底孔位4顆螺絲固定於牆壁(圖4)。需使
座中,請前先使具將敲下5
1. 壁掛度建1.5吋(38.1mm)
2. 螺絲非請使行處
2 將支固定
CAU TIO NCAU TIO N
PLEASE USE
5/16" OR M8
EXPANSION BOLT.
請搭配使用
膨脹螺栓。
5/16" M8
60mm
[圖3] [圖4] [圖5]
60mm
CAUTION
PLEASE USE
5/16" OR M8
EXPANSION BOLT.
請搭配使用
膨脹螺栓。
5/16" M8
將攝拆轉影機下,槽將盤與
架結合並將支架螺絲鎖緊固定(圖6&7);架轉門栓
往下底座8)。
:攝拆轉4螺絲全取可將盤卸
3 將攝拆轉架結
[8]
將攝全吊支架再將安全穿過支
9&10攝影上,落(11
4 將安穿過
[11]
[10][9]
將控穿過12),對準快拆轉盤及攝影機主體上的
刻痕,將攝影機主體以順時針方向旋入快拆轉盤(圖13)並將快拆
轉盤上的 4螺絲14)固定攝影機主體。
5 將控穿過安裝主體
[12]
[15]
AC100~240V
AC24V
Vid eo Signal
RJ-45
DC48V
Alarm Out
Alarm In
Audio & RS-485
6 連接組,型攝
序將接線 RJ-45線及組連(圖15
,接著再將支架鎖回支架底座(圖16),完成球型攝影機安裝
17
:以為建裝方依實的接明作調
在使用 Full HD IP攝影前,認攝RJ-45網路接頭和
源接接妥網管供一使用IP位址。
廠預IP位址為192.168.0.200,使用者可以先行使用該IP
更改相關網路設定。
裝前準備
您可以
IP位址、子網路遮罩、網路閘道、或HTTP接埠照下
1. 執行IPScan工具
2. 按「更新表單」鍵,區域網路內的所有設備將顯示在設備清單
3. 用滑該設
4. 編輯或修改該設備之IP網路網路(Gateway)
HTTP埠等
5. 按「鍵來設定
6. 按「單」証該
使IPScan(設備體)工具IP位址
使 軟體工具來設定 位址IPScan IP
廠預使用者密碼。 入Full HD 網路攝影機
請在面,使用者密碼確認同時
成使定並
Full HD 路攝要軟縮器像,Full HD
的網需使體。 當次登品,Full HD
網路攝影機的網頁介面會自動安裝Universal ActiveX請按
安裝裝該
體需求
先在覽器,輸IP位址192.168.0.200。並
下列行,使HTML更改IP位址:
1. 設定使名稱,登 Full HD IP攝影機
2. 按「組態設定」超連結
3. 按「網路設定」「一般設定」超連結
4. 輸入或修改IP網路網路(Gateway)HTTP
5. 按「鍵,述修
使 頁面來設定 位址HTML IP
1 8
2
3 3
碼強
. 密碼長 字以
. 密碼必英文小寫數字符號
. 密碼必使用 字型
[7][6]
ø184
184mm
368mm
8
9
10
11
12
13
14
15
1
2
3
4
56
7
使用硬復出值,下列
1. 按住出廠按鍵10 鐘。
2. 40網路 LED 燈將點亮
3. 網路伺服器將重新開機。
4. 使用 IPScan 軟體搜尋此 IP 設備。
5. 使用覽器 IP 設備。
6. 輸入預設使用者名稱及密碼進行操作。
廠預使用者密碼,由使自行
入。
方便使起見出廠會回 IP
192.168.0.200
1
2
復出廠預設值
IPCAM
[13][14]
[16][17]
/