If you are installing the device for the first time, please read this manual in advance and configure it step by step. Reboot the device once you finish the
configuration is required, including change the network environments, account number and so on. If you need more info, please go to our website
(www.flyingvoice.com) and download the user manual.
IP Phone Handset
Handset Cord
Stand Ethernet Cable Quick Installation Guide
4.3 Connect via wired network
Step1. Power on the phone.
Step2. Connect the Internet port of phone to the available network adapters (switches or routers) with Ethernet cable.
Step3. If there is DHCP server in network, you can find the IP address by pressing Menu >My Status.
Step1. Connect the phone to the Internet via the Internet port of the phone, connect your PC to the PC port of the phone with Ethernet cable.
Step2.
Step3. Enter the username (Default: admin) and password (Default: admin) in the login page and click Confirm.
Open web browser on your computer, enter the IP address (find the IP address by pressing Menu >My Status) into the address bar, and then press Enter key.
4.2 Accessing the web management
Enable,input SIP Account parameters.
SIP Account Parameters
Configure information
Line Enable Enable
192.168.1.1
621
621
Proxy Port
Outbound Port
Backup Outbound Port
Proxy Server
Display Name
Account
Phone Number
Password
Outbound Server
Backup Outbound Server
Allow DHCP Option 120 to
Override SIP Server
Outgoing Call without
Registration
5060
5060
5060
621
Basic Setup
Proxy and Registration
Subscriber Information
Name Description Name Description
Enable Line Enable Line or not
Outbound Proxy
Proxy Server Domain name or IP address of SIP server
Outbound proxy IP or domain name
Outbound Port Service port of outbound proxy
Phone Number Number of telephone provided by SIP proxy
Account SIP account provided by SIP proxy
Password SIP password provided by SIP proxy
Display Name The number displayed in callee
Proxy Port The port which SIP server supports of VoIP service. (Default: 5060)
Sync Clock Time Disable
Disable
Disable
4.4 Connect via Wi-Fi
Step1. Press button, then choose Basic Settings >Wi-Fi via ▲ or ▼ button.
Step2. Choose “Available Network”.
Step3. Use ▲ or ▼ button to select the network and press soft key “Con” to connect with it. Input the password if Wi-Fi authentication is required.
Note: If AP is connected, will appear in the status bar on the main interface.
4.1 Network Settings
There are two ways to configure the network settings.
DHCP: By default, the phone attempts to contact a DHCP server in your network to obtain its valid network settings. e.g., IP address, subnet mask,
gateway address and DNS address.
Static IP Address: If the phone can’t connect with DHCP server, please configure IP address, subnet mask, gateway address, primary
DNS address and secondary DNS address manually.
Packaging list
Power Adapter
(Optional)
Connect the stand
If you are using an external power supply, please connect the power supply, and plug the power supply into the
DC 5V supply hub on the back of the phone. Note: Only the power supply from Flyingvoice is available.
After the phone is connected the power supply, it will start the intialization process automatically. After that, the LCD will display “Flyingvoice” logo and
the phone will be ready to use. (Take the LCD screen of the P20 phone as an example.)
Note: If the phone does not show any above
information on the screen, please re-confirm
installation steps and the connections.
If it still doesn’t work, please replug the phone.
If there still no display on screen, please
contact the administrator or service provider.
1
Assembling the phone
2
Starting the phone
3
Input the device's IP address in the address bar of the browser. Then you can login SIP Account configure of the phone. Choose Enable on Line
Registering your phone
5
Declaration of Conformity
6
Configuring your phone
4
Wall mount the phone
Fix two appropriate screws on
the wall, and leave them about
1/4 distance from the wall.
Attach the mounting bracket to
the position to be installed, then
align and insert the mounting
hole and slide down, ensuring
the bottom slot has engaged.
DC5V
Power Adapter
Main screen PC Internet
Connect the handset
FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator & your body.
This product complies with the radio interference requirements of the European Community
Product name: IP Phone
Product model: P23GW, P22P
Manufacturer: Flyingvoice Network Technology Co., Ltd.
Address: 1801-1802, Building 1, Chongwen Park, Nanshan Zhiyuan, Nanshan District, Shenzhen, China
P23GW:
Frequency Range : 2412~2472MHz5150~5250MHz 5250~5350MHz 5470~5725MHz 5725~5850MHz
Max. output Power: 2412~2472MHz17.56 dbm5150~5250MHz 22.46 dbm5250~5350MHz 21.63 dbm5470~5725MHz
21.24 dbm5725~5850MHz 12.23 dbm
P22P:
Frequency Range (P22P): 2412~2472MHz (P22P)
Max. output Power: 18.42 dbm
SIMPLIFIED EU DECLARATION OF CONFORMITY
The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows:
Hereby, Flyingvoice Network Technology Co., Ltd. declares that radio equipment type P23GW/P22P is in compliance with Directive
2014/53/EU, and this product is allowed to be used in all EU member states.
The full text of the EU declaration of conformity is available at following.
This product can be used across EU member states.
EUT Operating temperature: -10~45°C
P2X Series IP Phone
www.flyingvoice.com
Quick Installation Guide
P2X Series IP Phone
www.flyingvoice.com
Quick Installation Guide
Qualified Certificate:
This product is qualified according to the delivery inspection.
QC
PASS